Raypak ® Swimming Pool Heat Pump OWNER’S MANUAL This manual should be maint ained in legible condition and kep t adjacent to the heat pump or in a safe p lace for future use. For additional information call: (800) 260-2758 Manual Ef fective Date: 6/24/2005 De ve lop ed an d p ri nt ed i n U .
i PRODUCT SAFETY SIGNS AND LABE LS This manual, as well as the pool/spa heat pum p itself, contains ANSI-approved product safety signs and labels. Please read these signs and labe ls, as they convey important safety information about hazards that may be potentially present in and around the heat pump.
ii Swimming Pool Heat Pump OWNER’S MANUAL - Mo dels 5300, 6300, 8300 CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Installation Considerations . .
1 Intr oduction This pool heat pump is an electromec hanical machine that incorporates a pressurized refrigerant gas in a sealed sys tem. ONL Y trained and qualified service personnel are authorized to install or service this eq uipment.
2 Situate the pool heat pump caref ully to minimize installati on costs while providing maximum efficiency of operation, and to allow adequate service access, as follows: • For unrestricted air intake and service access, pos ition each side of the unit at least 1 ft (30 cm) from walls, pipes and other obstructions.
3 III. W ater Connections The heat pump inlet and outlet connections are NOT interchan geable. They must be connected as instructed below . 1. Connect the heat pump in the return water line between the filter a nd the pool/spa. See page 10, Plumbing Diagrams.
4 interruption, this solid state devi ce will prevent compressor rest art for approximately 5 minutes. Upon power failure or interruption, a 6 to 8 minute delay will also be initiated.
5 V . System S tart-Up 1. V erify that th e Power lamp is ON and that the pool/spa pump is running and circulating properly . 2. V erify that the control panel Sp a-Remote-Pool switch is in the Remote (OFF) position; see the figure.
6 VII. Heat Pump Running T ime 1. Determine the length of pump and heat pump operating time necessary for your particular requirements. Minimum run time should be the required hours to attain proper water filtration.
7 X. Maintenance NOTE: The heat pump MANUF ACTURER IS NOT RESPONSIBLE for maintenance adjustments. The following maintenance procedures are desi gned to keep your heat pump operating at a high level of reliability .
8 • Is water condensing on the evaporator and intern al copper pipes? This is also evidence of heat removal from the air . When the air is c ool with low humidity , condensation may not be evident.
9 C. CONDENSA TION SEE MS EXCESSIVE Heat pumps can produce a large amount of condensation (water ) during operation. If you suspect that the heat pump is leaking: a. Use a pool chemistry test kit to confir m there is no chlorine in the condensation. Or , b.
10 Plumbing Diagrams For systems with pum ps of 2 HP or greate r (ove r 80 gpm ) , an ex te rn al bypass is required. Adjust the bypass valv e to divert a m inimum of 40 gpm through the hea t pu mp. Con nections ar e 2 -inch un ions. Plumb the heat pump af ter the filter and before any chlorinators.
デバイスRaypak 6300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raypak 6300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaypak 6300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raypak 6300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raypak 6300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raypak 6300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaypak 6300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raypak 6300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaypak 6300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。