W ARNING: If the information in these instructions are not followed ex- actly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art UL TIMA TE Rear V ent Direct V ent Gas Stove by FPI Fireplace Products International.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 3 T ABLE OF CONTENTS SAFETY LABEL Copy of Serial No. Decal ............................................... 4 REQUIREMENTS MA Code - CO Detector ................................
4 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove This is a copy of the label that accompanies each UL TIMA TE Rear V ent Direct V ent Free- standing Gas Stove. We have printed a copy of the contents here for your review . The safety label is located on the inside of the drop down pedestal door .
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 5 REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapte r 10 (2) Revise 10.8.
6 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The UL TIMA TE Rear V ent Direct V ent Freestand- ing Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 7 COMBUSTION AND VENTILA TION AIR The combustion air from this appliance is drawn from outside the building through the outer fl ue. Extra provision for combustion air inside the room is not required.
8 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove INST ALLA TION EXTERIOR VENT TERMINAL LOCA TIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(min.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 9 PLANNING YOUR VENTING INST ALLA TION INST ALLA TION IMPORT ANT Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty .
10 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 1 1 Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ American Metal Pr.
12 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove INST ALLA TION RIGID PIPE VENTING - VERTICAL TERMINA TIONS FOR BOTH RESIDENTIAL & MANUF ACTURED HOMES/MOBILE HOMES Off.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 13 INST ALLA TION Diagram 2a HORIZONT AL TERMINA TIONS Diagram 1 *Dia 2a & 2b: As specifi ed in CGA B149 Instal- lation Code. Local codes or regulations may require different clearances.
14 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove Diagram 5 Diagram 4 Below Grade Snorkel Installation If the Snorkel T ermination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from enter- ing the Snorkel T ermination.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 15 Flex Liner Exhaust Flue Air Intake Co-Linear Flex Adapter with Kit# 946-563 Co-linear DV V ertical T ermination Cap # 946-.
16 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove CONVERTING CLASS-A MET AL CHIMNEY OR MASONR Y CHIMNEY T O DIRECT VENT SYSTEM General There are two different types of direct vent conversion systems listed below . Follow the appropriate directions for your installation.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 17 CONVERTING MASONR Y CHIMNEY Important: The existing masonry fl ue open- ing needs to have an area of at least a 36 sq.
18 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove CONVERSION KIT# 514-969 FROM NG T O LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 19 15) V erify that if the conversion is from NG to LPG, the screw must be re-assem- bled with the red o-ring visible (Fig. 5). LPG Configuration Red o-ring visible Fig.5 16) R e-assemble the black protection cap (Fig.
20 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply , air supply or altitude.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 21 Cutout Pin Notch D)02-46 B)02-56 A)02-65 E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly agai.
22 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 23 W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
24 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove WIRING DIAGRAM This heater does not require a 120V A.C. sup- ply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 25 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
26 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Push in gas control knob slightly and turn to “PILOT” position. 2) Push in control knob all the way and hold in until the pilot lights up.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 27 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
28 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove MAINTENANCE LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res and after glass replacement. T urn the handle on the adjustable catch to tighten or loosen the latch.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 29 REMOVING V AL VE If your valve requires maintenance or replace- ment, use the following instructions: Note: A lways close off the gas supply before removing the valve. 1) Open front pedestal door.
30 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 6) Remove the two outside frame pieces by removing two screws per side. See diagram below .
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 31 P ARTS LIST 1) 560-920 Louver Assy - Gold 560-921 Louver Assy - Brush Nickel 560-922 Louver Assy - Black 9) 730-560 Relief.
32 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove P ARTS LIST BURNER & LOG ASSEMBL Y 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 90.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 33 DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926.
34 U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove NOTES ___________________________________________________ ___________________________________________________ ____________.
U37-1 Regency ® UL TIMA TE Rear V ent Direct V ent Freestanding Gas Stove 35 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency U37-LP1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency U37-LP1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency U37-LP1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency U37-LP1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency U37-LP1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency U37-LP1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency U37-LP1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency U37-LP1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency U37-LP1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。