FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-171a MODELS: I2400M WOOD Fireplace Insert 07/18/06 Owners & Installation Manual Installer : Please complete the details on the back cover and leave this manual with the homeowner .
Regency I2400M 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
Regency I2400M 3 THE REGENCY I2400 WOOD INSERT T ABLE OF CONTENTS SAFETY LABEL Safety Label ................................................................. 4 UNIT DIMENSIONS Unit Dimensions ...........................................................
Regency I2400M 4 SAFETY LABEL This is a copy of the label that accompanies your Regency Insert . W e have printed a copy of the contents here for your review . NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Regency I2400M 5 UNIT DIMENSIONS.
Regency I2400M 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice.
Regency I2400M 7 INST ALLA TION View from Rear of Insert OPTIONAL FLUE CONNECT OR KIT The Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl ue connector and the insert collar . Detailed installation instructions are included with the kit.
Regency I2400M 8 Clearance diagram for Installations Side and T op facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater . * Hearth thickness of 0.5" with k value = 0.
Regency I2400M 9 1) Positive Flue Connection with Cleanout FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection.
Regency I2400M 10 INST ALLA TION Faceplate Assembly Prior to sliding your insert into its fi nal position and attaching the connector or liner pipe, the faceplate side panel plates must be installed .
Regency I2400M 11 Ground Fan Fan Ground Green Neutral Live White Fan Switch Manual/ Auto Switch Black Black High (Black) Low (Red) Black Fan Thermodisc (normally open) 120V AC 60 Hz Thermo Switch Sensor INST ALLA TION STEP-BY -STEP INST ALLA TION OF THE F AN/BLOWER Blower/Fan Wiring Diagram 3) Slide the supports into the clips.
Regency I2400M 12 Pull Open Push Closed ensure the tube will not move when the unit is burning. Though there are four air tubes in the medium units. 2) Slide the left baffl e over the air tubes from the front and then push it to the back. 4) Important: push both baffl es so they are tight against the side walls.
Regency I2400M 13 OPERA TING INSTRUCTIONS FIRST FIRE When your installation is completed and in- spected, you are ready for your fi rst fi re. 1) Open draft control fully .
Regency I2400M 14 ASH DISPOSAL During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip. DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.
Regency I2400M 15 MAINTENANCE OF GOLD-PLA TED DOORS The gold electroplated fi nish on the doors requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty .
Regency I2400M 16 MAIN ASSEMBL Y & OPTIONS - I2400M P ARTS LIST Part # Description 142-917 Fan Assembly 24) 910-157/P Fan Motor 120 V olts 25) 910-678 Power Cord 120 V olts 27) 910-142 Fan Thermod.
Regency I2400M 17 P ARTS LIST F ACEPLA TES - I2400M Part # Description 140-91 1 Faceplate & T rim Set - Regular 285) 143-161 Trim Right Regular 286) 143-158 Trim T op Regular 287) 143-160 Trim Lef.
Regency I2400M 18 P ARTS LIST BRICK P ANELS - I2400M Part # Description 70) 902-1 1 1 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) 802-122 Brick Partial: 1-1/4 x 4-1/2" x 2&qu.
Regency I2400M 19 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . Regency Industries Ltd.
Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _______________________________________________________.
デバイスRegency Wraps I2400Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency Wraps I2400Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency Wraps I2400Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency Wraps I2400Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency Wraps I2400Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency Wraps I2400Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency Wraps I2400Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency Wraps I2400Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency Wraps I2400Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。