1 Instruction Manual KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. NOT FOR USE IN MANUF ACTURED (MOBILE) HOMES ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED T O THE LOCAL DEALER FROM WHOM THE W A TER HEA TER WAS PURCHASED.
2 SAFE INST SAFE INST SAFE INST SAFE INST SAFE INST ALLA ALLA ALLA ALLA ALLA TION TION TION TION TION , USE AND SERVICE , USE AND SERVICE , USE AND SERVICE , USE AND SERVICE , USE AND SERVICE Y our safety and the safety of others is extremely import ant in the inst allation, use and servicing of this water heater .
3 GENERAL SAFETY GENERAL SAFETY GENERAL SAFETY GENERAL SAFETY GENERAL SAFETY.
4 SAFE INST ALLA TION, USE AND SERVICE .............................. 2 GENERAL SAFETY .................................................................. 3 T ABLE OF CONTENTS .............................................................. 4 INTRODUCTION .
5 TYPICAL INST TYPICAL INST TYPICAL INST TYPICAL INST TYPICAL INST ALLA ALLA ALLA ALLA ALLA TION TION TION TION TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS * INST AL L IN ACCORDANCE WITH LOCAL CODES. * DRIP LEG AS REQUIRED BY LOCAL CODES. * ALL PIPING MA TERIALS TO BE SUPPLIED BY CUSTOMERS.
6 TYPICAL INST TYPICAL INST TYPICAL INST TYPICAL INST TYPICAL INST ALLA ALLA ALLA ALLA ALLA TION TION TION TION TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certified as complying with ANSI Z21.
7 1. Turn “OFF” the gas supply to the water heater . If the main gas line shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 3 and 4.
8 MA MA MA MA MA TERIALS AND BASIC T TERIALS AND BASIC T TERIALS AND BASIC T TERIALS AND BASIC T TERIALS AND BASIC T OOLS NEEDED OOLS NEEDED OOLS NEEDED OOLS NEEDED OOLS NEEDED DECIDING ON THE TYPE OF INST ALLA TION There are typically two different types of installations.
9 FACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
10 This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3” (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel.
11 Insulation blankets are available to the general public for external use on gas water heaters but are not necessary with Reliance products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters.
12 a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area.
13 FIGURE 15. SECTION A - GAL V ANIZED PIPING (See Figure 15) 1. Position the water heater so that the existing piping will require the shortest distance between connections. Make sure that you are able to reach the drain valve and all connections when the water heater is in place.
14 8. After checking that all connections are tight and the drain valve near the bottom of the water heater is closed, go to “Filling the Water Heater”. SECTION B COPPER (SWEA T) PIPING (See Figure 19) FIGURE 19. 1. Position the water heater so that the existing piping will require the shortest distance between connections.
15 shown. Clean the inside of each sweat fitting with the wire brush as shown. Make sure you do not touch the cleaned areas, see Figure 22. FIGURE 22. 7 . Using the diagram map out the installation. Screw fittings onto the nipples, hand tight. Then measure and cut the copper tubing.
16 TEMPERA TURE-PRESSURE RELIEF VAL VE This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer .
17 The temperature-pressure relief valve must be manually operated at least once a year . Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-press.
18 FIGURE 28. There must be a minimum of 6” (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance.
19 If a standard model is installed above 2,000 feet (610 m) or high altitude model is installed above 4,500 feet (1,370 m), the input rating should be reduced at the rate of 4 percent for each 1000 feet (305 m) above sea level which requires replacement of the burner orifice in accordance with National Fuel Gas Code ANSI Z223.
20 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1. Set thermostat to the lowest setting.
21 FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH W ATER AND AIR PURGED A T F AUCETS . W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
22 on the thermostat, read the “T emperature Regulation” section in this manual, see Figures 31 and 32. Never allow small children to use a hot water tap, or to draw their own bath water . Never leave a child or handicapped person unattended in a bathtub or shower .
23 c . Large amounts of hot water are used in a short time and the refill water in the tank is very cold. Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.
24 HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive.
25 BURNER CLEANING If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly . NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly .
26 The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary . 1. Turn the gas control knob to the “OFF” position. 2. CLOSE the cold water inlet valve to the water heater .
27 A . Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility . B . *Condensation may be seen on pipes in humid weather or pipe connections may be leaking.
28 These guidelines should be utilized by a qualified service agent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES Improperly sealed, hot or cold supply connection, Tighten threaded connections.
29 Key No. Part Description 1 Pipe Nipple 2 Burner T ube 3 Burner Head 4 Thermocouple 5 Pilot 6 Draft Hood * 7 Draft Hood Brace 8 Inlet T ube 9 Flue Baffle Assembly 1 0 Anode Rod 11 Cleanout Cover (op.
30 RESIDENTIAL GAS W ARRANTY THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . In accordance with the warranty terms and conditions specified below .
31 LIMIT A TION ON IMPLIED W ARRANTIES Implied warranties, including any warranty of merchantability imposed on the sale of this heater under state law are limited to one year duration for the heater or any of its parts. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
32 500 Lindahl Parkway Ashland City , TN 37015 www.reliancewaterheaters.com.
デバイスReliance Water Heaters 606 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Reliance Water Heaters 606 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはReliance Water Heaters 606 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Reliance Water Heaters 606 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Reliance Water Heaters 606 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Reliance Water Heaters 606 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はReliance Water Heaters 606 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Reliance Water Heaters 606 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちReliance Water Heaters 606 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。