RenesasメーカーH8/36014の使用説明書/サービス説明書
ページ先へ移動 of 30
2003.12.19 H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User’s Manual HS36014ECH64H Renesas Micro computer Development Environmen t System Rev.
Cautions Keep safety first in your circ uit desi gns! 1. Renesas Technology Corp . puts the maximum e ffort int o making s emiconducto r product s better and more reliable, but the re is always the poss ibility that trouble may occ ur with them. Trouble with semi conductors may lead t o personal i njury, fire or propert y damage.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m.
II LIMITED WARRANTY Renesas warrants its user system interface cabl es to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e cables dete rmined to be defective in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have other rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user sy stem interface cable until y ou fully understa nd its mec ha ni s m.
V W ARNING Observe the pr ecautions listed below. Failur e to do so will result in a FIRE HA ZARD and will damage the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric sho ck prevention and quality assurance.
i Preface Thank y ou for purchasi ng th is user s ys tem in terface cable (HS36014ECH64H) for the R enesas’s origin al microcom puter H8/36014series.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User Sys tem Interface C able to Emu lator Station (H8/36014 Series) .
1 Section 1 Configuration CAUTION Use an NQPACK048SD socket (manufactured by Tokyo Eletech Corporation ) for the FP- 48B package IC socket on the user system. Figu re 1 show s the config uration of the HS36014EC H64H user sy stem in terface cable for the FP-48B package.
2 Table 1 lists t he HS36014ECH64H com ponents . Please mak e sure y ou have all of th ese compon ents when u npacking. Table 1 HS36014ECH64H Com ponents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Cable to Emulator S tation (H8/36014 Series) W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
4 Figure 2 Connecting User System Interface Cable to Em ulator Station.
5 2.2 Connectin g User System Interface Cable to Ex pansion I/O Board (H8/36024 Series) W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from an y part. Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
6 Cable body connector User system interface cable CTS screws (M3 x 6 mm) Expansion I/O board cable USER INTERFACE CABL E6000 EMULATO E6000 Figure 3 Connecting User System Interface Cable to Expansion.
7 2.3 Connectin g User System Interface Cable to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
8 2.3.3 I nserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-48B packag e on the user sy stem w ith pin 1 on the u ser system interface cable head, and in sert the user system interface cable head into th e IC socket on the user sy stem, as show n in figure 4.
9 Fasten the us er system interf ace cable head to the IC socket for a FP-48B packag e on the user system with the four screws (M2 x 10 mm ) provided. Each screw should be tightened a little at a tim e, alternating betw een screw s on opposing corners.
10 2.3.5 Fastening Cable B ody Connect the cable body to the cable head. Figure 5 Fastening Cable Body.
11 2.4 Recomm ended Dimensions for User System Mount Pad Figure 6 show s the recomm ended dimens ions for the mou nt pad (footprin t) for the user system w ith an IC socket for an FP-48B pack age (NQPACK048SD: m anufactu red by Toky o Eletech Corporation).
12 2.5 Dimensions f or User System Interface Cable H ead The dimens ions for the user sy stem interface cable h ead are shown in f igure 7. ± Figure 7 Dim ensions for User System Interface Cable Head.
13 2.6 Resulting Di mensions after Conn ecting User System Interface Cab le The resulting dim ensions, after connectin g the user system interface cable head to the u ser system , are show n in figure 8.
14 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use the screwdriver provided fo r tightening screws.
15 Figure 9 Installing M CU to User System.
16 Section 4 Verifying Operation 1. When u sing the H8/ 36014 series E6000 em ulator (HS3664EPI61H), tu rn on the em ulator according to th e procedures described in the H8/300H Series E6000 Emu lator User's Manual (HS300HEPI61HE).
17 Figure 10 shows the sy stem clock oscillator on the user sy stem interface cable. Figure 10 System Clock Oscillator.
18 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head into the us er system IC sock et. 2. The dimens ions of th e recommen ded moun t pad for the user sy stem IC socket are diff erent from those of th e MCU.
19 Figure 12 P1 Short Connector.
H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.1.00, July 25, 2002 Rev.2.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
H8/3601 4 Grou p, H8/3 6024 Group FP -48B User Sy stem I nterface Cable for E 6000 Emulato r User’ s Manual REJ10B0093-0200H.
デバイスRenesas H8/36014の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas H8/36014をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas H8/36014の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas H8/36014の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas H8/36014で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas H8/36014を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas H8/36014の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas H8/36014に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas H8/36014デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。