RenesasメーカーH8S/2678 Seriesの使用説明書/サービス説明書
ページ先へ移動 of 19
H8S/2678 Series, H8S/2678R Series, H8S/2668 Series FP-144G/FP-144H User System Interface Cable (HS2678RECH61H) for E6000 Emulator User’s Manual HS2678RECH61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system in terface cable (HS2678RECH61H) for the Renesas’s original mi crocomputer H8S/2678 series, H8S/ 2678R series, H8S/2668 series.
ii Contents Section 1 Configuration ...................................................................................... 1 Section 2 Connection Procedures ....................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-144-045-B51 socket (manufactured by YAMAICHI ELECTRONICS C O., Ltd.) for the FP-144G/ FP-144H package IC socket on the user system. Figure 1 shows the configuration of the HS2678REC H61H user system interface cable for the FP-144G/FP-144H package.
2 Table 1 lists the HS2678REC H61H components. Please m ake sure you have all of these components when unpacking. Table 1 HS2678RECH61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Interf ace Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144G/FP-144H sy stem interface cable head into the IC socket on the user system, as shown i n figure 3. 2.2.4 Fastening Cable Head CAUTION 1.
Fasten the user system interf ace cable head to the IC socket for an FP-144G/FP-144H package on the user system with the four screws (M2 x 12 m m; wi th four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing co rners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. 8 Cable body Cable head User system unfastening jig Push the unfastening jigs. Removing Figure 4 Fastening Cable Body.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144G/FP-144H package (IC149-144-045-B51: manufactured by YAMAICHI ELECTRONICS CO.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. W hen using the E6000 emulator for t he H8S/2678 Series, H8S/2678R Series, H8S/2668 Series, turn on the emulator according to the procedures described in th e E6000 Series Emulator User' s Manual (HS2000EPI61HE). 2.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
デバイスRenesas H8S/2678 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas H8S/2678 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas H8S/2678 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas H8S/2678 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas H8S/2678 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas H8S/2678 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas H8S/2678 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas H8S/2678 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas H8S/2678 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。