RenesasメーカーH8SX/1648の使用説明書/サービス説明書
ページ先へ移動 of 44
H8SX/1648 Group E6 000H PLQP014 4KA-A User System Interface Board HS1648ECH61H User’s Manual Renesas M icrocomput er Developm ent Environm ent System H8SX Family / H8SX/ 1600 Ser ies HS1648EC H61HE REJ10J1869-0200 Revision Date: A pr. 18, 2008 Rev.2.
.
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with r.
.
I IMPORTANT INFORMATION READ FIRST • READ this user's ma nual befo re using this user system interface board. • KEEP the user's manual handy for future reference. Do not attempt to u se the user s ystem in terface board until y ou fully understand it s mechanism.
II LIMITED WA RRANTY Renesas warrants its user syst em interfa ce boards to be manufactu red in accordance with published specific ations and free from defects in material and/or workmanship. Renesas will repair or replace a ny user system interfac e boards determined to be defective in material and/or workmanship.
III State Law : Some states do not allo w the exclusion or limitation of implied warran ties or liability for incidental or c onsequential damages, s o the above limi tation or excl usion may not apply t o you. This warrant y gives you s pecifi c legal rights , and yo u may have ot her rights which ma y vary fr om state to state.
IV SAFETY PAGE READ FIRST • READ this user's ma nual befo re using this user system interface board. • KEEP the user's manual handy for future reference. Do not attempt to use the user sys tem in terface boa rd until you fully understand its mechanism.
V W ARNING Observe the pr ecautions list ed below. Fai lure to do so will result in a FIRE H AZARD and will damage the us er system and the emul ator product or will r esult in PERSONAL INJURY. The USER PROGRA M will be LOST. 1. Do not repair or remodel the emul ator product by yourself for e lectric shock pre vention and qualit y assurance.
VI.
i Preface The HS1648ECH61H is a us er system interface board that connects a user s ystem for the H8SX/1648 PL QP0144KA-A (former package: F P-144L) package to the H8S X/1650 E6000H emulator (HS1650EP H60H). Emulati on of the H8SX/1648 group i s only poss ible when thi s user system interface board is c onnected to the HS1650EPH 60H.
ii Content Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting the User System Interface B oard to the User System .
1 Section 1 Configuration Figure 1 and table 1 show the conf iguration and component s of the user sys tem interface board for the PLQP0144KA-A package.
2 CAUTION Use an NQPACK144SD -ND socket ( manufactured by Tokyo Eletech Corporation) as the PLQP0144KA- A-packaged IC socket on the user syst em. Table 1 HS1648ECH61H Com ponents No.
3 Section 2 Connection Procedures 2.1 Connecting the User Sy stem Interface Board to the User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE BOARD is connected or removed. Before connecting t he two, make sure that pin 1 on both sides are correct ly aligned.
4 To connect the b oard to the u ser system, follow the in structions below. 2.1.1 Installing the IC So cket After checking the locat ion of pin 1 on the IC s ocket fasten it to the user s ystem before soldering.
5 2.1.2 Soldering the IC Socket After fasteni ng, solder the IC socket for a PLQP0144KA-A package t o the user system. CAUTION Be sure to completely solder the leads so t hat the solder gently covers the leads and forms solder fillets. (Use slightly more solder than with the MCU.
6 2.1.4 Fastening th e IC Socket Connector CAUTION 1. Use the screwdriver provided fo r tightening screws. 2. The tightening torque must be 0.054 N•m or less. If the applied torque ca nnot be accurately measured, stop tightening when th e force required to tu rn the screw becomes significantly greater th an that needed when f irst tightening.
7 User system interface board User system Pin 1 Screws (M2 × 10 mm) (for fastenin g the board) IC socket (NQPACK144SD-ND manufactured by Tokyo Eletech Corporation) Figure 3 Connecting the User System.
8 2.2 Exchanging the Sp acers of the Evaluation-Chi p Board After connecting the user system in terface board to the us er system, be careful not to apply load to the user system. Exchange the spacers (2.6MP × 10 mm) of the evaluation-chip board with the spacers (2.
9 2.3 Connecting the User Syst em Interface Board to the Evaluation-Chip Board W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
10 Connector No. UCN1 UCN1 UCN2 UCN2 User system interface board Evaluation-Chip Board Connector No. Board Connector No. Evaluation-chip board Figure 5 Connecting the Us er System In terface Board to .
11 2.4 Recommended Dimensions for the User System Mounting Pad (Footprint) Figure 6 shows the recommended dimensi ons for the mounting pad (foot print) for the us er system with the IC s ocket for a PLQP0144KA -A package (NQPAC K144SD-ND: manufactured by Tokyo Eletech Corporati on).
12 2.5 Dimensions of the Evaluation-Chip Board and the User System Interface Board The dimensions of the evaluati on-chip board and the user s yst em interface board are shown in figure 7. Unit: mm Tolerance: ± 0.5 mm 140.0 Evaluation-chip board User system interface board 118.
13 2.6 Dimensions after Connecting th e User System Interface Board The dimensions of the ass embly after the user system interface board has been connected to the user syst em are shown in figure 8. Unit: mm Tolerance: ±1.0 mm 32.9 13.3 54.9 User system Evaluation-chip board IC socket (NQPACK144SD-ND manufactured by Tokyo Eletech Corporation) 56.
14 2.7 Using the Emulator with out Connecting User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE BOARD is connected or removed. Before connecting t he two, make sure that pin 1 on both sides are correct ly aligned.
15 SW1 USER ON USER OFF Figure 9 SW1 Jumper Socket Spacer (2.6MQ x 13 mm) Figure 10 Attaching Spacers.
16 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use the screwdriver provided fo r tightening screws.
17 MCU Pin 1 IC socket (NQPACK144SD-ND manufactured by Tokyo Eletech Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 11 Insta lling MCU to User System.
18 Section 4 User System Interface Circuits The following user system interface circuits are required to use the emulator with the user syst em interface board.
19 MCU User system Sub-MCU P30 P31 P34 P35 P36 P37 P20 P21 47 k Ω Vcc P30 P31 P34 P35 P36 P37 P20 P21 TIOCA0 TIOCB0 TIOCA1 TIOCB1 TIOCA2 TIOCB2 TIOCA3 TIOCB3 Figure 13 User System Interface Circuit (.
20 47 k Ω Vcc PF7 MCU User system SN74CB3Q3306A PF7 PF5 SN74CB3Q3306A PF6 PF6 PF5 Sub-MCU SCK5 RxD5 TxD5 Figure 14 User System Interface Circuit (3).
21 47 k Ω Vcc MCU SN74CB3Q3306A P65 SN74CB3Q3306A P64 P63 SCK6 RxD6 TxD6 Sub-MCU P65 P64 P63 User system Figure 15 User System Interface Circuit (4).
22 47 k Ω Vcc MCU EPM3256A TC ADTRG0 SW2 1 P13 PB6 P13 3 PB6 Sub-MCU User system 47 k Ω Vcc Figure 16 User System Interface Circuit (5).
23 Section 5 Verifying Operation 1. Turn on the emulator according to the pr ocedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH 60HE).
24 ⎯ To use the crysta l resonator mounted on the eval uation-chip board Install the cry stal resonator in to the crystal reson ator termin als on the evaluatio n-chip board.
25 Section 6 Points for Caution 1. Before connecting any parts or cables, make sure that the pi ns at the pin 1 pos ition on bot h sides are correctly aligned. 2. Do not apply excessive force to the user sy stem interface board while it is connected to the user sy stem.
26 Section 7 Restrictions 1. Deep-software standby mode This emulator does not support deep-s oftware standby mode. Note that the emulator switches to the software st andby mode ev en if the register setting to select the deep-s oftware standby mode is made.
27 8. A/D converter In the emulator, the evaluation ch ip and the slave chip are used to implement fun ctions of Unit 0 and Units 1 and 2, respect ively, of the A/D convert er.
28.
H8SX/1648 Group E6000H PLQP0144KA-A User System Interface Board HS1648ECH61H User's Manual Publication Date: Rev.2.00, April 18, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Suppor t Depar tment Global Strategic Communication Div .
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com Refer to " http://www.renesas.com/en/network " for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.
.
H8SX/1648 Gr oup E6000H PLQP0144KA-A User System Interface Board HS1648ECH6 1H User’s Manual.
デバイスRenesas H8SX/1648の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas H8SX/1648をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas H8SX/1648の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas H8SX/1648の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas H8SX/1648で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas H8SX/1648を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas H8SX/1648の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas H8SX/1648に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas H8SX/1648デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。