H8/3637 Series TFP-80F User System Interface Cable (HS3637ECN61H) for E6000 Emulator User’s Manual Rev. 4.0 4/1/03 Renesas Technology Corp. HS3637ECN61HE(D).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS3637ECN61H) for the Renesas’s original mi crocomputer H8/300L series. The HS3637ECN61H is a user system interface cab le that c.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-080-051-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-80F package IC socket on the user system. Figure 1 shows the configuration of the HS3637E CN61H user system interface cable for the TFP-80F package.
2 Table 1 lists t he HS3637ECN61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS3637ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cab.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Int erface Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pi n 1 on both sides are correctly aligned.
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TFP-80F package on t he user system wit h pin 1 on the user system interface cable head, and inse rt the user system interface cable head into the IC socket on the user system, as shown i n figure 3.
Fasten the user system interface cable head to the IC socket fo r an TFP-80F package on the user system with the four screws (M2 x 12 m m ; wit h four fl at washers) provided. Each screw shoul d be tightened a little at a time, alternating between scre ws on opposing corners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an TFP-80F package (IC149-080-051-B51: m anufactured by YAMAIC HI ELECTRONICS Co.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
MCU Pin 1 IC socket (IC149-080-051-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13.
14 Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulat or (HS3L08EPI60H), turn on the emulat or according to the procedures described in the H8/300L Series E6000 Em ulator User' s Manual (HS3008EPI60HE). 2. Verify the user system interface cable c onnections by accessing ports and checking the bus states of the pins.
Figure 9 shows the system clock oscillator on the us er system interface cable and the subclock input specifications. 15 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 0.8 Vcc 55 ns max. 55 ns max. 0.8 Vcc 0.3 Vcc 0 V Vcc Vcc: User System Vcc (3.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
デバイスRenesas TFP-80Fの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas TFP-80Fをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas TFP-80Fの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas TFP-80Fの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas TFP-80Fで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas TFP-80Fを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas TFP-80Fの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas TFP-80Fに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas TFP-80Fデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。