H8S/2655 Series TQFP-120 User System Interface Cable (HS2655ECN61H) for E6000 Emulator User’s Manual HS2655ECN61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2655ECN61H) for the Renesas’s original mi crocomputer H8S/2655 series. The HS2655ECN61H is a user system interface cable that c.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
1 Section 1 Configuration CAUTION Use an IC149-120-043-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-120 package IC socket on the user system. Figure 1 shows the configuration of the HS2655E CN61H user system interface cable for the TFP-120 package.
Figure 1 HS2655ECN61H User System Interface Cable 2.
3 Table 1 lists t he HS2655ECN61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2655ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Int erface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
6 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a T FP-120 package to the user system. Be sure to completely solder the leads so that the solder slo p s gently over the leads and fo rms solder fillets. (Use slightly more solder than the MCU.
Fasten the user system interface cable head to the IC socket for a TFP-120 package on the user system with t he four screws (M2 x 12 m m; with four flat washers) provi ded. Each screw should be tightened a little at a time, alternating between scre ws on opposing corners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for a TFP-120 package (IC149-120-043-B5: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 IC socket (IC149-120-043-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2655 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User's Manual (HS2000EPI61HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
6. The JP1 jumper connector is used for t esting. Do not remove t he inserted jumper pin. JP1 Figure 11 JP1 Jumper Connector 16.
デバイスRenesas TQFP-120の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Renesas TQFP-120をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRenesas TQFP-120の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Renesas TQFP-120の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Renesas TQFP-120で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Renesas TQFP-120を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRenesas TQFP-120の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Renesas TQFP-120に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRenesas TQFP-120デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。