GP90135 OPERA TOR’S MANUAL WHEELBARROW AIR COMPRESSOR Read and follo w all Safety Rules before fir st use of this product. ! WARNING IN610400A V Printed in U.
23 T able of Contents Section P age T able of Contents . . . . . . . . . . . . . . . .2 Safety Instructions . . . . . . . . . . . . . . .3 Safety Signal Words . . . . . . . . . . . . .3 Before Using the Air Compressor . . . . . . . . . . . . . . . . .
16. Fast moving air will stir up dust and debris which may be harmful. Release air slowly when draining moisture or depressurizing the com- pressor system. 17. STOP the engine whenever leaving the work area, before cleaning, making repairs or inspections.
7 6 Safety Instructions (contin ued) Find and read all warning labels found on the air compressor shown below W arning Labels ASME Safety V alve A safety valve that automatically releases the air if the air receiver (tank) pressure exceeds the preset maximum.
9 8 1. Remove the air compressor from the carton. 2. Place the compressor on a secure, stationary work surface and look it over carefully . Unpac king and Checking Contents Do not operate unit if damaged during shipping, handling or use. Dama ge may result in bur sting and cause injur y or property damage.
All lubricated compressor pumps dis- charge some condensed water and oil with the compressed air . Install appropri- ate water/oil removal equipment and con- trols as necessary for the intended appli- cation.
13 12 Operating Y our Air Compressor (continued) 5. Move the choke lever to the CHOKE position, turn the fuel lever ON, and turn the engine stop switch to the ON position. 6. Pull start grip lightly until resistance is felt, and then pull briskly . 7.
15 14 T o change a filter , pull off the filter housing cover . If filter element is dirty , replace ele- ment or entire filter . Filter Remov al, Inspection and Replacement Maintenance (continued) Belt stretch is a result of normal use.
17 16 T roubleshooting For your o wn safety do not try and run the air compressor while troub leshooting. ! WARNING TROUBLE PROB ABLE CA USE REMED Y Low discharge pres- sure 1. Air leaks 2. Leaking valves 3. Restricted air intake 4. Slipping belts 5. Blown gaskets 6.
19 18 T roubleshooting TROUBLE PROB ABLE CA USE REMED Y Excessive noise (knocking) Continued Oil in the discharge air 5. Worn bearings 6. Piston hitting the valve plate 7. Noisy check valve 1. Worn piston rings 2. Compressor air intake restricted 3. Restricted breather 4.
21 20 Repair P ar ts Repair P ar ts For Repair P arts, Call 1-800-4-RIDGID Please provide f ollowing information: -Model number -Serial number (if any) -Part description and number as shown in parts l.
23 22 Notes Notes.
RIDGID ® AIR COMPRESSOR LIMITED THREE YEAR W ARRANTY AND 90- D A Y SA TISF A CTION GUARANTEE POLICY This product is manufactured by The Campbell Group under a trademark license from Ridgid, Inc. All warranty communications should be directed to The Campbell Group, attn: RIDGID air compres- sor technical service at (toll free) 1-800-4-RIDGID.
デバイスRIDGID GP90135の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RIDGID GP90135をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRIDGID GP90135の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RIDGID GP90135の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RIDGID GP90135で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RIDGID GP90135を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRIDGID GP90135の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RIDGID GP90135に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRIDGID GP90135デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。