RIDGIDメーカーOL50145MWの使用説明書/サービス説明書
ページ先へ移動 of 20
1 Y our air compressor has been engineer ed and manufactured to our high standar d for dependability , ease of operation, and operator safety . When properly car ed for , it will give you years of rugged, trouble-fr ee performance.
2 Introduction....................................................................................................................................................................... 2 General Safety Rules ................................
3 GENERAL SAFETY RULES WARNING: Read and understand all instructions. Failure to follow all instructions listed below may r esult in electric shock, fir e, and/or serious personal injury . SA VE THESE INSTRUCTIONS WORK AREA Keep your work area clean and well lit.
4 Kno w your po wer to ol. Re ad oper ato r’ s ma nua l car efu lly . Learn its applications and limitations, as well as the specific potential hazar ds related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury .
5 SYMBOLS Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter - pretation of these symbols will allow you to operate the pr oduct better and safer .
6 SYMBOLS SERVICE Servicing requires extr eme care and knowledge and should be performed only by a qualified service technician. For service we suggest you return the product to your near est AUTHORIZED SERVICE CENTER for repair . When servic- ing, use only identical replacement parts.
7 EXTENSION CORDS Use only 3-wire extension cords that have 3-prong ground- ing plugs and 3-pole r eceptacles that accept the product’ s plug. When using a power tool at a considerable distance fr om the power sour ce, use an extensio n cor d he avy en ough to carry the current that the tool will draw .
8 GLOSSAR Y OF TERMS Pressur e Regulator Knob Regulates the outgoing pressure from the air outlet to the tool. It is possible to increase or decrease the pressure at the outlet by adjusting this control knob. Pressur e Switch Automatically controls the on/off cycling of the compressor .
9 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.
10 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.
11 ASSEMBL Y INST ALLING THE DIPSTICK See Figure 4. The air compressor has a label installed between the oil fill hole and a travel cap. Before using the unit the first time, remove travel cap and label and insert supplied dipstick. Make sure to add oil befor e first use.
12 ON OFF O I ON 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE OPERA TION DANGER: Do not disasse mble check valve, tank drain valves or safety relief valve with air in tank — bleed tanks.
13 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE Attach 1/4 in. NPT male connector fitting to accessory or tool you intend to use.
14 CHECKING THE SAFETY V AL VE See Figure 12. DANGER: Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failur e to heed this warning could result in death or serious personal injury . The safety valve will automatically release air if the air tank pressur e exceeds the preset maximum.
15 ON OFF O I ON MAINTENANCE WARNING: When servicing use only identical RIDGID ® replacement parts. Use of any other parts may create a hazar d or cause product damage. WARNING: Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust.
16 ON OFF O I ON MAINTENANCE Fig. 15 DRAIN PLUG OIL FILL HOLE COLLECT USED OIL IN A SUIT ABLE CONT AINER CHANGING THE OIL See Figure 15. Replace the oil after the first 100 hours of operation and every 100 hours following the first oil change. Place a suitable container underneath the drain to collect used oil.
17 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Compressor will not run Loss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Thermal overload open Pressur e switch .
18 Proof of purchase must be presented when requesting war - ranty service. This product is manufactured by One W orld T echnologies, Inc. The tra demark is lice nsed from RIDGID, Inc. Al l warra nty commu nication s shoul d be directe d to One W orld T echnolo- gie s, Inc.
19 NOTES.
20 Customer Service Information: For parts or service, contact your near est RIDGID ® authorized service center . Be sure to provide all relevant information when you call or visit. For the location of the authorized service center nearest you, please call 1-800-4-RIDGID or visit us online at www .
デバイスRIDGID OL50145MWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
RIDGID OL50145MWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRIDGID OL50145MWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。RIDGID OL50145MWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。RIDGID OL50145MWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
RIDGID OL50145MWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRIDGID OL50145MWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、RIDGID OL50145MWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRIDGID OL50145MWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。