A division of Rockford Corporation HOME THEA TER AUDIO F A10.0 F A12.0 F A15.0 AMPLIFIED SUBWOOFERS OWNER’S MANUAL POINT ZERO SERIES.
Declaration of Conformity Application of Council Directive: 73/23/EEC (Low V oltage Directive) 89/336/EEC (EMC Directive) Standard(s) to which Conformity is Declared: EN55103-1 EN55103-2 EN60065 Manuf.
– i – 25Hz-100Hz, ±2dB @ 18hz >1 15dB (w/music @ 2m) <3%, 25Hz (90dB @ 2m) 12” (305mm) Cellulose Fibre Cone Santoprene Rubber Surround 2.5” (63.5mm) 4-Layer V oice Coil 102 oz. Magnet 1.8ft 3 (50.4Liter) Bass Reflex Down Firing 16.75”(H) x 18.
– ii – Power Rating Signal-to-Noise CMRR Input Impedance Input Sensitivity Range Maximum Input Gain Crossover Frequency V ariable from 40Hz~140Hz Crossover Slope 24dB/octave (4th order) Linkwitz-Riley Subsonic Filter 12dB/octave (-3dB @ 18Hz) Specifications are subject to change without notice.
– iii – PERFORMANCE SPECIFICA TIONS Frequency Response Graphs …………………………………………………………………………… i INTRODUCTION ………………………….
– 1 – The F A10.0, F A12.0, and F A15.0 monitors utilize a specially designed amplifier featuring our innova- tive T rans • ana cir cuitry . This topology , with its unique input-to-output configuration (derived from our patented T rans • nova cir cuit), employs power gain in the MOSFET output stage that result in superior sound quality .
– 2 – MEHSA (Maximum Efficiency HeatSink Application) MEHSA is a proprietary process that yields up to 5 times better heat transfer than traditional FET mounting techniques using the exact same components.
– 3 – Subsonic Filter The Point Zero series uses a Subsonic Filter to prevent the woofer from reproducing inaudible frequen- cies. Subsonic frequencies, (known as infrasonic frequencies), are signals below the normal human hearing range.
– 4 – 1. RCA Input/Speaker Level Input Switch 2. Gain Control 3. RCA Input 4. RCA Output (full range) 5. Speaker Line Input 6. Speaker Line Output (Full range) 7.
Home Theater Installations Home Theater installations are typically medium sized living rooms or game rooms that have large, flat walls. Acoustics in this type of installation can have a big effect on the SPL (Sound Pressure Level) and f3 (low frequency cut-off) of the subwoofer because the walls are very reflective.
– 6 –.
– 7 – Installation using RCA (low le v el) Inputs.
– 8 – * This graph was generated by setting the variable crossover to 40Hz 50Hz, 60Hz, 70Hz, 80Hz, 90Hz, 100Hz, 120Hz & 140Hz. Auto T urn-on / Sleep Mode The Fosgate Audionics subwoofers automatically turn on when they sense an input signal.
– 9 – Phase Control The Phase Control switches allow the Fosgate Audionics subwoofer to be acoustically aligned with other speakers in your system. 0 ˚ , -90 ˚ , -180 ˚ , or -270 ˚ degrees of phase shift at 80Hz can be selected using DIP switches 2, 3, and 4.
– 10 – AC Line The F A10.0/F A12.0/F A15.0 operate from a 1 15 V AC/60Hz power line. The F A10.0CE/F A12.0CE/F A15.0CE operate from a 230 V AC 50/60Hz power line. Connection is made by a 16 gauge, IEC T ype 320, grounded line cord. For safety considerations only a properly grounded (earthed) receptacle should be used.
– 11 – Rockford Corporation (Fosgate Audionics Division) offers a limited warranty on Fosgate Audionics prod- ucts on the following terms: • Length of W arranty 1 year on Subwoofer Monitors • What is Covered This warranty applies only to products sold to the original owner and is non-transferable.
– 12 – The lightning flash with arrowhead symbol within an equilateral tri- angle is intended to alert the user to the presence of uninsulated “ dan- gerous voltage ” within the product ’ s enclosure, that may be of suffi- cient magnitude to constitute a risk of electric shock to persons.
– 13 – 1. LEA LAS INSTRUCCIONES T odas las instrucciones de seguidad y operaci ó n de su equipo Fosgate Audionics, deben ser le í das antes de que el equipo sea conectado dl é ctricamente. 2. CONSERVE EL MANUAL DEL PROPIET ARIO Estas instrucciones de seguridad y operaci ó n, deben ser conser- vadas para futuras referencias.
– 14 – 1. LIRE LES INSTRUCTIONS Le mode d ’ emploi et les mesures de s é curit é de votre é quipement Fosgate Audionics devraient ê tre consult é s avant sa mise en marche. 2. CONSERVER LE GUIDE DE L ’ UTILISA TEUR Le mode e ’ emploi et les mesures de s é curit é devraient ê tre conserv é s pour des r é f é rences futures.
– 15 – 1. INSTRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Fosgate Audionics Equipments sollten vor der Inbetriebnahme gelesen werden. 2. BETRIEBSANLEITUNG AUFBEW AHREN Bewahren Sie die Bedienungsanleitung sorgf ä ltig auf, damit Sie in dieser auch in Zukunft nachschlagen k ö nnen.
– 16 – 1. LEGGETE LE ISTRUZIONI T utte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all ’ apparato. 2. CONSERV A TE IL MANUALE Queste istruzioni riguardanti la sicurezza ed il funzionamento devono essere conservate come riferimento futuro.
– 17 – Notes.
– 18 – Notes.
02/2001 LIT1 1450-A MADE IN THE USA This product is designed, developed and assembled in the USA by a dedicated group of American workers. The majority of the components used in the construction of this product are produced by American companies.
デバイスRockford Fosgate FA12.0の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rockford Fosgate FA12.0をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRockford Fosgate FA12.0の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rockford Fosgate FA12.0の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rockford Fosgate FA12.0で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rockford Fosgate FA12.0を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRockford Fosgate FA12.0の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rockford Fosgate FA12.0に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRockford Fosgate FA12.0デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。