Roll Laminator Service Manual MODEL:RSH-380SL.
3 ~ 3 4 ~ 10 4 ~ 6 6 ~ 7 7 ~ 9 9 ~ 10 11 ~ 11 12 ~ 14 12 ~ 12 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 14 14 ~ 14 15 ~ 16 17 ~ 19 20 ~ 25 26 ~ 29 30 ~ 33 4.Adjustments …………………………………………………………………………………… 5.
Safety Precaution 1. Safety Precautions Failure to comply any of the following safety procedures could result in serious injury. Please read the instructions carefully and keep for future reference. 1. Only a licensed electrician should install wiring and outlet for the laminator.
Note: While repairing: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. c. Be sure to follow the steps below in order. 2.1 Rollers Not Heating CAUSES: 1. Improper laminating mode. 2. Heating wire is not connected to the main PCB.
2. Blown (burnt) wire fuse (T/Fuse). a. Replace the T/Fuse wire located on the left-hand side. 3. Defective Bi-Metal. a. Replace the Bi-Metal 4. Defective heater. a. Using the multi-meter, test the continuity of the heater. If it fails, replace the heater.
5. Defective Main PCB. a. Replace the PCB Main. 2.2 Rollers Over Heating CAUSES 1. Heat sensor is reversed on the PCB Main. 2. Defective T/Fuse wire. 3. Defective heater. 4. Defective main PCB. MEASURES 1. Wires for lower and upper heat sensors are reversed on the main PCB.
4. Defective Main PCB. a. Replace the PCB Main. 2.3 Rollers Not Running CAUSES 1. No power to the unit. 2. The main switch is close. 3. Opened safety cover. 4. Film is jammed on the rollers. 5. Disconnected motor wire. 6. Defective main motor. 7. Defective main PCB.
4. Film is jammed on the rollers. a. Un-jam the film using a combination of the pressure lever and reverse button. 5. Disconnected motor wire. a. Check the motor wire connection with PCB.
7. Defective main PCB. a. Replace the main PCB. 2.4 No Main Power CAUSES 1. No electricity. 2. Blown main fuse. 3. Disconnected main power wires. 4. Defective transformer. MEASURES 1. No Electricity. a. Double check to insure that you have electricity from your outlet.
4. Transformer is defective a. Replace the transformer. Problem: Straight wave lines across the output. Cause: Excessive front roller pressure. Measure: Loosen the front roller pressure. Problem: Concave waves in the lamination. Cause: Excessive rear (pulling) roller pressure.
Note: While replacing parts: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. 3.1 Replacing the Right Cover. a. Take out the pressure lever (Figure 1) and four cover screws using Phillips screw driver (Figure 2).
3.4 Replacing the Heaters Note: Cotton or surgical gloves are recommended while handling the heater assembly. a. Disassemble Right and Left Covers (Refer to “ Replacing Right Cover ” and “ Replacing Left Cover ”). b. Take out the heater brackets on each side by loosening screws (Figure 8, 9).
.2 Adjusting front and rear roller s Pressure • Use Screwdriver to adjust the roller pressure: C.W – Increase pressure. C.C.W – Decrease pressure. 1. Using Push-Pull Scale , measure 3 spots as shown on Figure B &C: Front roller should be 5~6 and back rollers should be 6~8.
021LR0001A COVER-L ABS PA-765 UL94 V-0 PANTON 431 125LR4001A HANDLE-TENSION S45C Cu+Ni+Cr 138LR4012A SPRING-TENSION SWP Ф 3.2 12200X022A BEARING-RADIAL 15*28 141LR4033A PLATE-PRESSURE,PULL SPCC 3.0T 138LR4015A SPRING-PRESSURE SWP Ф 2 141LR4032A PLATE-PRESSDURE,LAMI SPCC 3.
141LR4043A FRONT TABLE SAFETY LEVER SPCC 1.5T 013LR4004A SAFETY FRAME SPCC 021LR3024A SAFETY-COVER PC 3.0T 014LR3001B TABLE-FRONT AL6063 133LR3001A ROLLER-LAMI STPG ORG 223LR3001H HEATER ASS'Y FC.
350LR3043A PCB-SUB ASSY FR-4 36600X001A FUSE-BLOCK FB66 LITTLE FUSE TRIAD INC 32500X0008 FUSE-MAIN 65TS AC250V 10A EU,AU,KR,CH,UK,EU(N),BR 32500X0005 FUSE-MAIN 65TS AC250V 20A TW,CUL,JOL,JAP 021LR3018A COVER-R ABS PA-765 UL94 V-0 PANTON 431 138LR4001A SPRING-CUTTER CROSS SWRH Φ 0.
No. Part No. Part Name 1 021LR0001A COVER-L 2 125LR4001A HANDLE-TENSION 3 138LR4012A SPRING-TENSION 4 12200X022A BEARING-RADIAL 5 141LR4033A PLATE-PRESSURE , PULL 6 138LR4015A SPRING-PRESSURE 7 141LR4.
16 7. Wire Diagram 1 2 3 4 5 6 78 A B C D 8 7 6 5 4 3 2 1 D C B A T i tle Numbe r Revision Si ze A2 D a t e : 6 -M ar -2 00 9 S he e t o f Fi le: D: PR O GR A M FI L ES EXAMPLES R SL-3 8 2S CI RS L-3 82 S C I.
1. Wire Main. 6. Wire Power Transformer In 2. Wire Power 7. Wires Power Transformer Output 3. Wire Heater , up 8. Wire Fuse 4. Wire Heater , low 5.
18 SUB PCB Wire Bimetal Wire Up Heater Wire Lo Heater Bimetal(135 ℃ ) Power Cord Fuse Main Motor Wire Sensor.
19 Wire T/Fuse (133 ℃ ) Wire Safety S/W Wire Motor Micro Switch.
デバイスRoyal Sovereign RSH-380SLの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Royal Sovereign RSH-380SLをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRoyal Sovereign RSH-380SLの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Royal Sovereign RSH-380SLの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Royal Sovereign RSH-380SLで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Royal Sovereign RSH-380SLを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRoyal Sovereign RSH-380SLの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Royal Sovereign RSH-380SLに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRoyal Sovereign RSH-380SLデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。