AudiovoxメーカーPROFESSIONAL SERIES CA 5550SSTの使用説明書/サービス説明書
ページ先へ移動 of 24
1 2010 Audiovox Electronics Corporation. All rights reserved. PROFESSIONAL SERIES Remote S t art with Keyless Entry Inst allation Guide CA 5550SST.
2 2010 Audiovox Electronics Corporation. All rights reserved. Before Y ou Begin ...................................................................................... 3 Wire Connection Guide ............................................................
3 2010 Audiovox Electronics Corporation. All rights reserved. PROFESSIONAL INST ALLA TION STRONGL Y RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during insta.
4 2010 Audiovox Electronics Corporation. All rights reserved. 6 Pin S t art Harness 4 Pin Alternate Harness 2 Pin Lock Harness 7 Pin Main Harness 3 Pin Parking Light Harness.
5 2010 Audiovox Electronics Corporation. All rights reserved. 7 Pin Main Harness 1 BLACK/WHITE ILLUMINA TED ENTRY OUTPUT ( - ) This wire provides a ( - ) 500mA output for 30 seconds when the system is disarmed capable of driving relays. Locate the vehicle’s dome light or pin switch wire.
6 2010 Audiovox Electronics Corporation. All rights reserved. 5 PURPLE/WHITE T ACH INPUT Locate the vehicle’s ignition coil or fuel injector in the engine comp artment. V erification: T est using the following procedure: 1. Set voltmeter to AC VOL TS.
7 2010 Audiovox Electronics Corporation. All rights reserved. 6 GRA Y HOOD PIN INPUT ( - ) Install a Hood Pin Switch and connect to the GRA Y wire. This connection is required for Remote S tart. V erification: This wire when connected will register ground when the vehicle's hood is opened.
8 2010 Audiovox Electronics Corporation. All rights reserved. 6 Pin S t art Harness 1 PURPLE ST ARTER OUTPUT ( + ) Locate the vehicle starter wire. V erification: This wire registers voltage only when the key is turned to the ST ART position. Verification: The starter wire registers voltage when the key is turned to the ST ART position.
9 2010 Audiovox Electronics Corporation. All rights reserved. 6 PINK IGNITION 1 ( + ) Locate the vehicle’s ignition wire at the ignition switch. V erification: This wire registers voltage when the key is turned to the ON (or RUN) position. The volt age does not drop out when the key is turned to the ST AR T (or CRANK) position.
1 0 2010 Audiovox Electronics Corporation. All rights reserved. 4 BLACK/YELLOW PULSE DURING CRANK ( - ) Locate the vehicle’s second st arter (crank) wire at the ignition switch. (if equipped) V erification: This wire registers volt age only in the st art (crank) position of the ignition switch.
11 2010 Audiovox Electronics Corporation. All rights reserved. Negative Switching Locks All Door Lock and Unlock: Locate the lock / unlock wire at the vehicle’s lock / unlock switch. V erification: These wires will register ground when the Lock and Unlock switches are activated.
1 2 2010 Audiovox Electronics Corporation. All rights reserved. Reverse Polarity Locks (5-Wire Door locks) All Door Lock and Unlock: Locate the lock / unlock wire at the vehicle’s lock / unlock switch. V erification: These wires will rest at ground and register positive voltage when the Lock and Unlock switches are activated.
13 2010 Audiovox Electronics Corporation. All rights reserved. Positive Multiplexed Locks All Door Lock and Unlock: Locate the lock / unlock wire at the vehicle’s lock / unlock switch. V erification: This wire will show variable positive volt age when the switch is activated.
1 4 2010 Audiovox Electronics Corporation. All rights reserved. Data Bus Interface Port This 4 pin port is used for Flashlogic Door Lock and Transponder Databus Interfaces to communicate with the vehicle's Databus.
15 2010 Audiovox Electronics Corporation. All rights reserved. Manual Feature Programming - Feature Bank 2 - 4 1. Turn the ignition ON. 2. Press and hold the valet/override button. 3. Within 10 seconds the system will chirp (3) three times. 4. Use the valet/override button to advance through each option bank.
1 6 2010 Audiovox Electronics Corporation. All rights reserved. Feature Bank 1 - 3 Chirp s Transmitter Progr amming Refer to transmitter programming..
17 2010 Audiovox Electronics Corporation. All rights reserved. T ach Programming The unit will not operate unless a tach signal is programmed or the tachless option is turned ON .
1 8 2010 Audiovox Electronics Corporation. All rights reserved. Feature Bank 2 - Security 1 - Silent Choice: Controls the normal arm/disarm chirps of the security system. ON - Silent arming/disarming upon first press of lock/unlock, pressing lock/ unlock a second time will activate the arm/disarm chirps respectively .
19 2010 Audiovox Electronics Corporation. All rights reserved. 3 - Ignition Controlled Locks: Control of door locks when the ignition is cycled ON or OFF . OFF - Door locks not activated by ignition. Lock and Unlock - Doors lock when ignition is turned on and unlock when ignition is turned of f.
2 0 2010 Audiovox Electronics Corporation. All rights reserved. 4 - T ach Mode: Determines how the system monitors the engine running during remote start.
21 2010 Audiovox Electronics Corporation. All rights reserved. 9 - Single / Double Pulse Start: Switches the remote start activation between a single or double press from the transmitter . 10 - IGN 2 Output: Programmable high current output. Ignition 2 - Ignition output during remote start.
2 2 2010 Audiovox Electronics Corporation. All rights reserved. Remote Start Shutdown Diagnostics If the remote start shuts down or fails to start, the parking lights will flash one of the patterns below indicating the shutdown input. T o manually enter diagnostics and view the last shutdown, turn the ignition ON and press and release the button.
23 2010 Audiovox Electronics Corporation. All rights reserved. L T GREEN/BLACK F ACTOR Y DISARM / PULSE BEFORE ST ART ( - ) L T BLUE PULSE AFTER ST ART ( - ) GREEN/WHITE F ACTORY ARM / PULSE AFTER SHU.
2 4 2010 Audiovox Electronics Corporation. All rights reserved. Audiovox Electronics Corporation. Customer Service 1-800-421-3209 WWW .CODE-ALARM.COM FCC COMPLIANCE This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada.
デバイスAudiovox PROFESSIONAL SERIES CA 5550SSTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Audiovox PROFESSIONAL SERIES CA 5550SSTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAudiovox PROFESSIONAL SERIES CA 5550SSTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Audiovox PROFESSIONAL SERIES CA 5550SSTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Audiovox PROFESSIONAL SERIES CA 5550SSTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Audiovox PROFESSIONAL SERIES CA 5550SSTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAudiovox PROFESSIONAL SERIES CA 5550SSTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Audiovox PROFESSIONAL SERIES CA 5550SSTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAudiovox PROFESSIONAL SERIES CA 5550SSTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。