OWNER’S INSTRUCTIONS & INST ALLA TION MANUAL FLOOR ST ANDING TYPE AIR CONDITIONER ( Cool ) AP500PF E S DB68-00054A(1).
Safety Precautions The following safety precautions must be taken when using your air conditioner . 1 Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 2 NEVER spill liquids of any kind into the indoor unit.
Contents ◆ P REP ARING Y OUR A IR C ONDITIONER ■ Safety Precautions ......................................................................................................... 2 ■ View of the Indoor Unit & Outdoor Unit ........................
View of the Indoor unit and Outdoor unit AIR FLOW(DIRECTION) ADJUSTING BLADE AIR OUTLET CONTROL P ANEL AIR FIL TER AIR INLET GRILLE T o disassemble the air inlet grille ◆ Loosen two fixing screws of left and right. Hold the upper part of the air inlet grille, and then pull it lightly forward.
Remote Control - Buttons Control Panel Fan Speed display Fan Speed adjustment T ime/T emperature Selection Operating Mode Selection T imer adjustment Power Light T ime or T emperature adjustment T ime.
Getting Started Y ou have just purchased a packaged air conditioner and it has been installed by your installation specialist. Y our Owner's Instructions contain much valuable information on using your air conditioner . Please take the time to read them as they will help you take full advantage of the unit's features.
Inserting the Remote Control Batteries Y ou must insert or replace the remote control batteries when: ◆ Y ou purchase the air conditioner ◆ The remote control does not work correctly N N N N o o o o t t t t e e e e Use two LR03(AAA) 1.5V batteries.
Setting the Time Y ou can set the time when you purchas the air conditioner . N N N N o o o o t t t t a a a a Be sure to reset the time when you change clocks from standard todaylight saving time and vice versa. 1 Press the TIME/TEMP . SELECT button. Result: The TIME indicator flashes.
Y ou can operate with indoor unit when you do not wish to or cannot operate the air conditioner with the remote control. Y ou can : Adapt the auto operating, cooling, fan and timer setting to your specific requirements ; See pages 10 to 15 for further details.
Y ou can start the air conditioner in AUTO mode. 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode previously set is displayed. ◆ The air conditioner starts up in the mode selected when the unit was last used.
Y ou must select the COOL mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode previously set is displayed.
The turbo function is used to cool your room as quickly as possible. Example: Y ou have just come home and find that the room is very hot. Y ou wish to cool it down as quickly as possible. The turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
Airing Y our Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary , press the ON/OFF( ) button. Result: ◆ The power indicator on the control panel comes on. ◆ The indoor unit beeps twice. ◆ The operation mode previously set is displayed.
Adjusting the Air Flow Direction Horizontally Depending on the position of the indoor unit, you can adjust the position of the air flow blades on the top of the unit, thus increasing the efficiency of the air conditioner . Y ou can controll by using remote control.
Setting the Off Timer The Off T imer enables you to set the air conditioner to switch off automatically after a given period of time, by pressing one single button. The unit can be switched off automatically after one hour , two hours, three hours, four hours or five hours.
Operating Recommendation Here is a recommendation that you should follow when using your air conditioner . TOPIC RECOMMENDA TION Power failure If a power failure occurs while the air conditioner is operating, it is switched off. When the power returns, you must press ON/OFF( ) to restart it.
Cleaning Y our Air Conditioner T o get the best possible use out of your air conditioner , you must clean it regularly to remove the dust that accumulates on the air filter . IM PORT ANT Before cleaning your air conditioner , ensure that you have switched off the breaker used for the unit.
Problem Explanation / Solution The air conditioner does not operate at all The air conditioner does not operate with the remote control The air conditioner does not cool The fan speed does not change .
T echnical Specification E- 19 Cooling Capacity BTU/h Moisture Removal Pts/h Indoor Air Flow (High) CFM Sound rating dBA Power Source ø /V/Hz Power Consumption W Operating Current A Max. TD Fuse/Breaker A Dimension W x H x D in Shipping Weight Ibs Liquid Line O.
ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY : Printed in Korea.
ACCESSORY P ARTS LIST • Connection Parts . . . . . . . . . . . . . . 21 • Others . . . . . . . . . . . . . . . . . . . . . . 21 SELECTION OF INST ALLA TION PLACE • Indoor Unit . . . . . . . . . . . . . . . . . . . 22 • Outdoor Unit . . . . . .
ACCESSOR Y P ARTS LIST Connection Parts Others 1 2 3 4 5 6 7 8 9 Drain hose Connecting pipe Connecting pipe Connection wiring (3 strand) Insulation for piping Finishing tape Insulation tape Insulation tube for indoor unit piping connection Ring terminal 1 1 1 1 1 2 1 1 8 No.
SELECTION OF INST ALLA TION PLACE ❈ If there is any unavoidable reason to install the unit at such a place, take the following measures against the wind; 1. When installing the unit at a roadside concentrated with buildings, install it parallel with the road.
ELECTRICAL WORK Power Ampere of breaker Knife switch Size of grounding wire Min. size of electric wires from/to the indoor/outdoor unit Size of electric input wires Switch Fuse 3phase 3wires 208 ~ 230V / 60Hz 50 A 30 A 30 A A WG 14 A WG 19 A WG 1 9 The electrical work should be performed by a specialist qualified for the work.
ELECTRICAL WORK RS T RS T OUTDOOR SIDE Power terminals on the outdoor unit Red Red White White Black Black Knife switch or automatic circuit breaker Electric input wires Indoor / outdoor unit connecting wire 1. Remove cover of electric box on side panel of outdoor unit.
E- 25 / INST ALLA TION METHOD INST ALLA TION METHOD Installation Procedures 1. Open the inlet grille, and remove the flare nut. 2. Bend the connection pipe to an appropriate length using the spring bender depending upon the installation place.
A 1.8 mm(7/100") 2 mm(9/100") INST ALLA TION METHOD 90 Oblique Roughness Burr D A Outer Diameter ø 9.52 mm(3/8") ø 19.05 mm(3/4") ◆ Unproper flaring Inclined Surface damaged Cracked Uneven thickness Final T orque 450 kg • cm(32 ft • lb) 750 kg • cm(54 ft • lb) Remarks Outer Diameter ø 9.
E- 27 Drilling a Hole in the W all Drain Hose Rat-prevention Cover ◆ Drill a hole of 70mm(3 inch) in diameter to the outside. ◆ The drilling should be done at a distance of less than 150mm(6 inch) from the floor facing the indoor unit.
In order to install drain hose through wall, adjust height (max. 150mm/5.91 inch) of the indoor unit using leg holder . B A Anchor bolt fixing dimensions Nut A 840(33 inch) B 415(16.4 inch) Unit:mm(inch) Outdoor unit leg Leg holder Foot holder ❏ Fixing to the floor ◆ When using the leg holder of the indoor unit.
1. Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port (3/4" Packed valve) as shown at the figure. 2. Open the valve of the low pressure side of manifold gauge counter-clockwise. 3. Purge the air from the system using vacuum pump for about 10 minutes.
REFRIGERANT CHARGING Air purge(at the time of new installation only) Close the gas pipe side valve by turning it clockwise. Connect the pressure gauge to the low pressure side service valve, and then open the gas pipe side valve again. Connect it to the refrigerant filling tank.
CHECK AND TEST OPERA TION E- 31 / CHECK AND TEST OPERA TION ◆ Be sure to check the following again after completion of installation. 1. Check the piping connection area for any gas leakage. 2. Is the drain hose properly connected? 3. Is the insulation of the piping in good condition? 4.
CHECK AND TEST OPERA TION ◆ After checking, read the owner ’ s instructions carefully , and perform a test operation. Then deliver the unit to the customer . (When delivering the unit, be sure to read carefully and follow the contents of the owner ’ s instructions.
E- 33 MEMO MEMO.
デバイスSamsung AP500Fの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Samsung AP500Fをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSamsung AP500Fの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Samsung AP500Fの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Samsung AP500Fで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Samsung AP500Fを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSamsung AP500Fの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Samsung AP500Fに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSamsung AP500Fデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。