SanyoメーカーCL2432の使用説明書/サービス説明書
ページ先へ移動 of 17
Contents Page IMPORT ANT! Please Read Before Starting .................................. 1 1. GENERAL .......................................................... 2 1-1. T ools Required for Installation (not supplied) 1-2. Accessories Supplied with Indoor Unit 1-3.
1 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently .
2 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.
3 1-6. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 2. Installation Site Selection 2-1.
4 2-2. Outdoor Unit A VOID: ● heat sources, exhaust fans, etc. (Fig. 4a) ● damp, humid or uneven locations. DO: ● choose a place as cool as possible. ● choose a place that is well ventilated. ● allow enough room around the unit for air intake/ exhaust and possible maintenance.
5 Indoor side Outdoor side Set screws f or transportation only Right-rear tubing (recommended) Right tubing Left-rear tubling Fig. 6 Fig. 7a Center of left-rear tubing hole Center of right-rear tubing hole Fig. 7b NOTE Hole should be made at a slight downward slant to the outdoor side.
6 3-3. Install the Rear Panel on the W all Be sure to confirm that the wall is strong enough to sus- pend the unit. See either Item a) or b) below depending on the wall type. a) If Wooden W all (1) Attach the rear panel to the wall with the 10 screws provided.
7 How to replace the grille (1) Close the flaps. (2) Reinstall the grille into the lower part while aligning its tabs on the upper part. (Fig. 15a) Insert the tabs in the slots and push the lower part of the grille back into position. (3) Press at each of the 5 tabs to completely close the grille.
8 3-7. Recommended Wire Length and Diameter Regulations on wiring diameter differ from locality to locality . For field wiring requirements, please refer to your local electrical codes. Carefully observe these regu- lations when carrying out the installation.
9 3-8. Wiring Instructions for Inter-unit Connections (1) Insert the inter-unit wiring (according to local codes) into the through-the-wall PVC pipe. Run the wiring toward the indoor side allowing approx.
10 When connecting each power wire to the corresponding terminal, follow the instructions “ How to connect wiring to the terminal ” and fasten the wire securely tight with the fixing screw of the terminal plate.
11 3-9. Mounting ■ Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 24) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel.
12 3-10. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 28) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation * so that chilled condensation will not damage furniture or floors.
13 4. Refrigerant T ubing 4-1. Indoor Unit T ubing ■ Rear-left tubing For rear-left tubing, optional tube connection (C) (APR- EN46U1B) is necessary . Please consult your nearest sales outlet or A/C workshop. 1. Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A and B) on the rear panel.
14 4-3. Connecting T ubing between Indoor and Outdoor Units a) T ightly connect the indoor side refrigerant tubing extended from the wall with the outdoor side tubing.
(2) Wrap the armoring tape from the bottom of the out- door unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn. (Fig. 36) (3) Clamp the tubing bundle to the wall, using 1 clamp approx.
16 5. Remote Control Unit Installation Position The remote control unit can be operated from either a non-fixed position or a wall-mounted position. T o ensure that the air conditioner operates correc.
デバイスSanyo CL2432の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sanyo CL2432をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSanyo CL2432の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sanyo CL2432の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sanyo CL2432で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sanyo CL2432を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSanyo CL2432の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sanyo CL2432に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSanyo CL2432デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。