SanyoメーカーKMS0972の使用説明書/サービス説明書
ページ先へ移動 of 25
© SANY O 2006 Pub . OI-85264180806000 • INSTR UCTION MANU AL • MODE D’EMPLOI In verter-Contr olled Split System Air Conditioner Climatiseur de type séparé contrôlé par in ver seur Save These Instructions! Conserver ce mode d’emploi KMS0772 KMS0972 KMS1272 This air conditioner uses the ne w refrigerant R410A.
2 F eatures This air conditioner is an in v er ter type unit that auto matica lly adjusts capacity as appropriate . Details on these functions are prov ided below; ref er to th ese descriptions when using the air conditioner .
3 Contents P age F eatur es ............ ............. ............. ................ ............. ............. ................ ............ 2 Product In f or matio n .... ............. ................. ............ ............. ................ .
4 Installation Location • W e recommend that this air conditioner be installed pr operly b y qualified installat ion technicians in accorda nce with the In stallation Instructions pro vided with th e unit.
5 Names of P ar ts This illustration is based on the e x ternal view of a standard model. Consequently , the shape ma y diff er from that of the air condition er which you hav e selected. This air conditioner consists of an indoor unit and an ou tdoor unit.
6 Unit Displa y and Operation Button REMO TE CONTROL receiver This section pic ks up infrar ed signals from the remote control u nit (transmitter). OPERA T ION button When the remote control cannot be used, pressin g this button enables cooling operati on.
7 Remote Contr ol Unit (Display ) (1) Operat ion mode MILD DR Y .... ............. ............ . COOL .............. ............. .......... F AN .......... ................. ............ . (2) F an speed A utomatic op eration ............... HIGH .
8 Remote Contr ol Unit The illustration abov e pictures the remote control unit after the c ov er has been opened. Tr a n s m i t t e r When you press the b uttons on the remote control unit, the mark appears in the displa y to transmit the setting changes to the re ceiver in the air conditioner .
9 Remote Contr ol Unit (continued) T emperature setting b uttons (TEMP .) Press the but ton to increase the set temper ature . Press the button to reduce th e set tempe rature. The tempera ture setting changes b y 1 °C or 2 °F each time one of the TEMP .
10 Remote Contr ol Unit (continued) Using the Remote Control Unit SENSOR button When yo u press this butt on (use a small-tipped object such as a ballpo int pen), the mar k will appear at the displa y . And the room temp erature is detected by the sensor wh ich is built into the indoor u nit and the air conditioner is controlled accordingly .
11 Using the Remote Cont ro l Unit (continued) How to Use the Remote Control Un it When using the remote control unit, alw ays point the unit’ s transmitter head directly at the air condit ioner’ s receiv er .
12 Oper ation with the Remote Control Unit 1. Operation Check th at the circuit break er on the po wer panel is turned on. Press the setting b uttons as described below and change the settings as desired. STEP 1 Press the MODE selector b utton and select th e desired mode.
13 Operation with the Remote Contr ol Unit (continued) • Choose the best position in the r oom f or the remote control unit, wh ich also acts as the sensor f or room comf ort and transmits the oper ating instructions. Once yo u’ve f ound this best po sition, alwa ys k eep the remote control unit there .
14 Operation with the Remote Contr ol Unit (continued) 4. Night Setbac k Mode Night Setbac k Mode is used f or savi ng energ y . Press the NIGHT SETBA CK button while oper ation. The mark appears in the displa y . T o release t he night se tback function, pre ss the NIGHT SETBACK b utton aga in.
15 Operation with the Remote Contr ol Unit (continued) 5. QUIET Mode QUIET Mode is used to re duce the f an sound of the indo or unit. Press the QUIET b utton. The mark appears in the displa y . T o cancel, p ress QUIET button again. • In QUIE T Mode, the f an rotat es at a slower spee d than the f an speed settin g.
16 Special Remar ks How it w orks? • Once the room temper ature reaches the le v el that w as set, the unit’ s oper ation frequency is changed auto matically . • Durin g DR Y operation, the fan speed au tomatically r uns at lower speed for providin g a comfortable bree ze.
17 Setting the Timer In the descriptions belo w , the f ollowing set tings are used f or th e temperatur e and time indicator select or butt on on the bottom front se ction of the remote contr ol. • T emperature: °F • Time: AM, PM 1. How to set the p resent time (Example) T o set to 10:30 pm.
18 Setting the Timer (continued) 3. How to set the ON time (Example) T o star t operation at 7: 10 am. 4. How to set D AIL Y ON/OFF REPEA T timer (Example) T o star t operation at 7:10 a m. and stop the air cond itioner at 11:00 am. T o cancel a timer pr ogram • Press the CANCEL bu tton.
19 Using the 1-Hour OFF Timer Tips f or Energ y Sa ving 1. 1-Hour OFF Timer This function causes the unit to operate f or one hour and then stop, regard less of whether the unit is on or off when this b utton is pressed. The indicator in the displa y indicates that this funct ion is operating.
20 Adjusting the Airflo w Direction 1. Horizontal The horizontal air flow can be adjust ed by mo ving the v er tical vane s with your hands to the left or right. When the humidity is high, the vertical va nes should be in the front position during the cooling or dehumidifying operation.
21 Oper ation without the Remote Control Unit Care and Cleaning INDOOR UNIT If y ou hav e lost the r emote control un it or it has troub le, f ollo w the steps below . When the air conditi oner is not running Each time the OPERA TION button is pressed, the op eration mode chan ges cyclically .
22 Care and Cleaning (continued) Anti-Mold Filter The anti-mold filter behind the air intake grille should be ch eck ed and cleaned at least once e ve r y two weeks . How to remove the anti-mold filter 1. Grasp both ends of the air intake grille, and remo ve it b y opening to wards t he front and pulling tow ards you.
23 Care and Cleaning (continued) Air Clean Filt er The air clean filter remov es dust and dirt from the air , and reduces odors an d smoke from tobacco. This air clean filter cannot remove harmfu l gases or vapor s nor ventilate air in the room. Y ou must open doors or windows frequently when you use gas or oil heating appliance s.
24 T roub leshooting If your air conditioner does not work pr oper ly , first check the f ollowing points bef ore requesting service. If it still does no t work properly , contact yo ur dealer or service center .
25 01_KMS0972_En.fm Page 25 Mon day, November 14, 2005 1:24 PM.
デバイスSanyo KMS0972の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります: