SanyoメーカーSPW-UMR224EXH56の使用説明書/サービス説明書
ページ先へ移動 of 38
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SM940046 SPW-UMR94EXH56 854.0.2264 SPW-UMR224EXH56 854.0.2267 0.8180.439.0 June 2005 SPW-UMR124EXH56 SPW-UMR164EXH56 SPW-UMR184EXH56 854.0.2266 Model No. Product Code No. SPW-UMR74EXH56 854.
IMPORT ANT! Please read before installation This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently .
Page 1. SPECIFICATIONS 4 1-1 Unit specifications 4 1-2 Major Component specifications 7 1-3 Other Component specifications 10 2. DIMENSIONAL DATA 11 3. ELECTRICAL DATA 13 3-1 Electric Wiring Diagram 13 3-2 Control PCB switches and functions 14 4. FUNCTION 15 4-1 Room Temperature Control 15 4-2 Automatic control for heating and cooling 16 5.
1. SPECIFICATIONS 1-1 Unit Specifications SPW-UMR74/94/124EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote.
SPW-UMR164/184EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.
SPW-UMR224EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.
1-2 Major Component Specifications SPW-XMR74/94/124EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp.
SPW-XMR164/184EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp.
SPW-XMR224EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp.
1-3 Other Component Specifications Trasformer Rating Primary Secondary 1 Secondary 2 Secondary 3 Thermal cut-off temp. Thermistor ( Coil sensor E1, E2 ) Resistance k Ω Thermistor ( Coil sensor E3 ) .
2. DIMENSIONAL DATA SPW-UMR74/94/124EXH56 11.
SPW-UMR164/184/224EXH56 12.
3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 7P terminal board 1(L) 2(N) U1 U2 R1 R2 w i r i ng remote con t ro ll e r power supp ly inter-unit con t ro l 13.
3-2 Control PCB switches and functions CR-TRP50A-B OC (CN040) EMG (CN044) VARISTOR (VA041) JP1 DISP (CN072) EXCT (CN073) FILTER (JP001) (CN070) CHK (CN071) FAN DRIVE GRL (CN032) (CN020) T10 (CN061) POWER LED (D002) EEPROM (IC010) T10: 6 plug (yellow): used for remote control.
4. FUNCTIONS 4-1 Room temperature control 15.
4-2 Automatic control for heating and cooling 16.
5. REPLACING PCB 5-1 Replacing PCB About EEPROM (Erasable Programmable Read-Only Memory) EEPROM is a component in which the various information necessary for functionning can be electronically written or erased. This component holds informations that is essential for the running of the unit, and must be handled with care.
5-2 How to replace PCB 18.
5-3 How to replace EEPROM with EEPROM included in PCB service pack 19.
20.
5-4 Table of settings 21.
6. SERVICING AND MAINTENANCE FUNCTIONS 22.
7. TROUBLE DIAGNOSIS 7-1 Contents of remote controller switch alarm display 23.
24.
7-2 Outdoor unit control panel LED display 25.
7-3 Trouble indications and inspection points 26.
27.
7-4 Remote controller servicing functions 28.
7-5 Super W-Multi alarm codes 29.
30.
31.
32.
33.
34.
7-6 Inspection of parts 35.
36.
37.
SANYO Airconditioners Europe S.r.l. Via Bisceglie, No.76 20152 Milano, Italy.
デバイスSanyo SPW-UMR224EXH56の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sanyo SPW-UMR224EXH56をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSanyo SPW-UMR224EXH56の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sanyo SPW-UMR224EXH56の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sanyo SPW-UMR224EXH56で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sanyo SPW-UMR224EXH56を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSanyo SPW-UMR224EXH56の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sanyo SPW-UMR224EXH56に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSanyo SPW-UMR224EXH56デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。