SanyoメーカーXS1852の使用説明書/サービス説明書
ページ先へ移動 of 27
1 S4359128 INST ALLA TION INSTR UCTIONS IMPORTANT Page Please Read Before Starting 1. GENERAL ............................................................. 3 1-1. Tools Required for Installation (not supplied) 1-2. Accessories Supplied with Unit 1-3. Optional Copper Tubing Kit 1-4.
2 S4359128 When Transporting …………………………………………………………………… Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back.
3 S4359128 1-3. Optional Copper Tubing Kit Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or A/C workshop. 1-4.
4 S4359128 1-7. Tubing Length ● Refrigerant tubing between the indoor and outdoor units should be kept as short as possible. ● Select and decide the installation location so that the length of the refrigerant tubing will be within the limits given in Table 1-2.
5 S4359128 2. Selecting the Installation Site Indoor Unit AVOID: ● areas where leakage of flammable gas may be expected. ● places where large amount of oil mist exist. ● direct sunlight. ● locations near heat sources which may affect performance of the unit.
6 S4359128 Out- door unit Heat source Hot air Exhaust fan 1817_C_I NO Fig. 2-2 Min. 7 ft. (2 m) Min. 7 ft. (2 m) Min. 6 in. (15 cm) Air intake Ground Obstacle Obstacle above Air discharge 1819_M_I Air intake Min. 6" (15 cm) Air discharge Min. 6" (15 cm) Min.
7 S4359128 Fig. 3-1 Fig. 3-2 Hole-in-anchor Hole-in-plug Concrete Insert Suspension bolt (M10 or 3/8") (field supply) 0038_T_I Fig. 3-3 0962_S_I A (ceiling opening dimension) 820 (ceiling opening.
8 S4359128 3-3. Placing the Unit Inside the Ceiling (1) When placing the unit inside the ceiling, deter- mine the pitch of the suspension bolts using the supplied full-scale installation diagram. (Fig. 3-4) The size of the opening for the indoor unit can be confirmed by attaching the full-scale installation diagram beneath the unit.
9 S4359128 3-4. Installing the Drain Piping (1) Prepare standard hard PVC pipe (O.D. 1-3/64 in.) for the drain and use the supplied drain hose and hose band to prevent water leaks. The PVC pipe must be purchased separately. The transparent part allows you to check drain- age.
10 S4359128 3-5. Checking the Drainage After wiring and piping are completed, use the follow- ing procedure to check that the water will drain smoothly. For this, prepare a bucket and wiping cloth ready to catch and wipe up spilled water. Do not supply power to the unit until the tubing and wiring to the outdoor unit are completed.
11 S4359128 Safety string Air filter 0150_X_I 45° Fig. 3-13 Ceiling panel Air intake grille Latch 0149_X_I Screw ■ Ceiling Panel Never touch or attempt to move the air direction louver by hand or you may damage the unit. Instead, use the remote control unit if you want to change the direction or air flow.
12 S4359128 NOTE NOTE 0967_X_I Ceiling panel Ceiling panel Mark Screws M5 with washer Ceiling panel wiring connector Air filter Air-intake grille Panel catch (pull down) Connector on unit (inside electrical component box) Connector of ceiling panel Unit body Panel catch (pull down) Electrical component box Electrical component box Clamp Fig.
13 S4359128 3-9. Duct for Fresh Air ● Air-intake chamber (including Duct connection box and flange) are attached to the indoor unit when used to take fresh outdoor air. High-performance filter or Super long-life filter can be also installed in the air-intake chamber.
14 S4359128 (b) INST ALLING THE AIR-INT AKE CHAMBER ● Set the air-intake chamber to the indoor unit taking care not to set to the incorrect direction.
S4359128 15 4. How to Install the Remote Control Unit ■ Wireless Remote Control Unit The remote control unit can be operated from either a non-fixed position or a wall-mounted position.
16 S4359128 ■ Wired Remote Control Unit (Option) (1) To access the printed circuit board, remove the cover plate of the electrical component box. (2) Attach the remote control connectors securely to the mating connector pins on the printed circuit board.
S4359128 17 5. Address Switches If you are installing one indoor unit or one group of indoor units in the same room, it is necessary for you to assign each unit its own address so that each can be operated by its own remote control unit.
18 S4359128 6. Electrical Wiring 6-1. General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram.
S4359128 19 ● Conduit's trade size for this unit is 1/2". The conduit can be purchased at a hardware store. ● The fuse located in the outdoor unit provides power supply protection and may blow when power is applied if the system has been incorrectly wired.
20 S4359128 Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, ensure that all wiring is tightly connected.
S4359128 21 7. How to Process Tubing The narrow tubing side is connected by flare nut, and the wide tubing side is connected by brazing. 7-1. Use of the Flaring Method Many of the conventional split system air conditioners employ the flaring method to connect refrigerant tubes which run between indoor and outdoor units.
22 S4359128 7-4. Precautions during Brazing ● Replace air inside the tube with nitrogen gas to prevent copper oxide film from forming during the brazing process. ● Do not allow the tubing to get too hot during the brazing process. The nitrogen gas inside the tubing may overheat, causing refrigerant system valves to become damaged.
S4359128 23 Because capillary tubing is installed in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. Therefore, to prevent heat loss and wet floors due to dripping of condensation water, both tubes must be well insulated with proper insulation material.
24 S4359128 CAUTION 8. Air Purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. Therefore, they must be purged completely.
S4359128 25 (5) With the vacuum pump still running, close the “Lo” knob of the manifold valve. Then stop the vacuum pump. (6) With the accessory hex wrench, turn the valve stem on the narrow tube service valve counter-clockwise by 90 degress (1/4 turn) for 10 seconds, and then turn the stem clockwise to close it again.
26 S4359128 9. Test Run 9-1. Performing Test Run Be careful since the fan will start when performing Test Run. (1) The Operation Selector is located on the electrical component box inside the indoor unit. To access the Operation Selector, press the two latches of the air intake grille in the direction of the arrow to open the grille.
S4359128 27 9-3. Basic Function of the Service Valves The basic function of the service valves are given in Table 7 below. Action Narrow Tube Service Wide Tube Service Valve (2-Way) Valve (3-Way) 1826.
デバイスSanyo XS1852の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sanyo XS1852をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSanyo XS1852の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sanyo XS1852の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sanyo XS1852で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sanyo XS1852を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSanyo XS1852の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sanyo XS1852に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSanyo XS1852デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。