www.schneider-electric.com Siemens AG SIMATIC S7 Ethernet 04/2010.
2.
3 Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About the Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 1 SIMATIC S7 Ethernet . . . . . . . . . . . . . . . . . . . . .
4.
5 § Safety Information Important Information NOTICE Read these instru ctions carefully, and look at the equipment to become familiar with the device before trying to install, operat e, or maintain it.
6 PLEASE NOTE Electrical equipment should be installed, o perated, serviced, and maintained only by qualified personnel. No re sponsibility is assumed by Schnei der Electric for any consequences arising out of the use of this material .
7 About the Book At a Glance Document Scope This manual describes the device driver commu nication settings in the Vijeo- Designer screen editing software. Vijeo-De signer enables you to design Magelis target machines that communicate with PLCs, drives, field devices, and oth er equipment.
8 Product Related Infor mation * For additional information, refer to NEMA ICS 1.1 (latest edition) , “Safety Guidelines for the Application, Installa tion, and Maintenance of Solid State Control.“ User Comments We welcome your comments about this do cument.
9 1 SIMATIC S7 Ethernet SIMATIC S7 Ethernet Subject of this Chapter This chapter explains the SIMATIC S7 Ethernet. What's in this Chapter? This chapter contains the following topics: Topic Page S.
SIMATIC S7 Ethernet 10 System Structure Overview The following table describes the basic system setup fo r connecting the target machine to Siemens S7-200/300/400 Series PLCs over a netwo rk.
SIMATIC S7 Ethernet 11 *2 PLC supports a maximum of 64 conn ections. Because 2 conn ecti ons are required for each target machine, one for Fetch and one for Write, the PLC can support up to 32 target machines. *3 The direct connection to the Ethern et Interface on th ese CP Us only supports the “OP Communication” type.
SIMATIC S7 Ethernet 12 Supported Device Addresses Overview The following tables list the device addre ss ranges you can enter from the Device Address keypad. For actual device address range s supported by the PLC, refer to the corresponding PLC manual.
SIMATIC S7 Ethernet 13 *6 Data blocks are created by the user. Available a ddresses depend on what the user has created. *7 PLC word addresses defined for integer, float, and string variab les mu st be even-numbered. i.e., IW5 is not a valid device address for an integer variable.
SIMATIC S7 Ethernet 14 *7 PLC word addresses defined for integer, float, and string variabl es must be even-numbered. i.e., IW 5 is not a valid device address for an integer variable. Must be either IW4 or IW6. *8 16-bit and 32-bit data , High and Low, refer to data as defi ned in the following example s.
SIMATIC S7 Ethernet 15 Consecutive Equipment Add resses Overview The following table lists the maximum number of consecutive addresses that can be read by each PLC. Refer to this table w hen using block transfers. Note : z To speed up data communicatio n, use consecutive variable addresses on the same panel screen.
SIMATIC S7 Ethernet 16 I/O Manager Configuration Overview The driver and equipment, which enab le communication between the target machine and the PLC, depends on the PLC type. Screen example of I/O Manager Configuration Note : z For informatio n on how to display the [New Driver] dialog box, see the online help.
SIMATIC S7 Ethernet 17 Equipment Configuration Overview To set up details about the communicati on process between the target machine and the PLC, use the [Equipment Configuration ] di alog box. For an overview of the driver and equipment settings, see Equ ipment Configuration .
SIMATIC S7 Ethernet 18 Fetch/Write Screen Description Area Description IP Address Enter the PLC unit’s IP address. PLC Ports Fetch Specify the PLC’s TCP port number for the Fetch operation. Specify values between 1024~65535. Write Specify the PLC’s TCP port number for the Write operation.
SIMATIC S7 Ethernet 19 S7-300/400 Series Screen De scription Note : z The IP Address and PLC Ports field s s hould match the communication settings on the PLC unit. z The connection configuration on the PLC can be configured t o accept onl y specified host IP addresses and specifie d host ports.
SIMATIC S7 Ethernet 20 Device Address Configuration Overview To set up a PLC variabl e in the Variable List, use the Device Address Keypad from the variable properties.
SIMATIC S7 Ethernet 21 Screen De scription Area Description Memory Area Lists the device type. Data Block D efines a number for a valid dat a block. This field is available when DB is selected as theMemory Area. To enter a valid data block, click the Data Block field’s ellipsis to display the[Data Block Selector] keypad.
SIMATIC S7 Ethernet 22.
デバイスSchneider Electric S7の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Schneider Electric S7をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSchneider Electric S7の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Schneider Electric S7の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Schneider Electric S7で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Schneider Electric S7を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSchneider Electric S7の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Schneider Electric S7に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSchneider Electric S7デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。