Installation and User's Manual for Self Contained Cubers Models CU1526, CU2026 and CU3030.
Introduction The design of this cuber is the result of years of experience and testing. Standard features include a removable bin for service and an on-off switch at the front of the cabinet for easy operational control. Keep this manual for future reference.
Installation: Product Specifications Location Limitations: The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room. Water cooled models discharge warm water into the building’s drain.
Model Number Description Example: • CU2026SA-1A • C= cuber • U=under the counter type • 20= nominal ice capacity in 10s of pounds • 26= nominal width of cabinet • S= Cube size. S=small or half dice cube. M=medium or full dice cube • A=Condenser type.
Water The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. Water can contain impurities either in suspension or in solution. Suspended solids can be filtered out.
CU1526 and CU2026 Cabinet Layout May 2008 Page 5 CU1526, CU2026, CU3030 User Manual 5.48 13.9 39.0 99.0 22.12 56.2 4.00 MINIMUM UTILITY CLEARANCE 10.2 6.00 15.2 22.25 56.5 29.65 75.3 27.5 69.9 4.86 12.3 26.62 67.6 30.04 76.3 15.55 39.5 2.60 6.6 4.85 12.
CU3030 Cabinet Layout May 2008 Page 6 CU1526, CU2026, CU3030 User Manual 5.30 13.5 39.0 99.0 25.95 65.9 4.69 11.9 30.0 76.2 30.62 77.8 4.00 MINIMUM UTILITY CLEARANCE 10.2 6.00 15.2 24.25 61.6 29.63 75.3 6.99 17.7 3.19 8.1 4.33 11 29.36 74.6 2.77 7 4.65 11.
Ice Storage Bin Removal The ice storage bin is removable to allow access to the refrigeration system for service. 1. Remove front louvers. Remove left then right. 2. If the machine is in an ice making mode, push and release the Manual Harvest button to release any ice that might be on the evaporator.
Plumbing Requirements Connect to cold, potable water. A hand actuated valve within site of the machine is required. Air cooled models have a single 3/8” male flare inlet water connection. Water cooled models have an additional 3/8” FPT condenser inlet water connection, and a 1/2" FPT condenser drain.
Electrical The machine is supplied with a power cord. 208-230 volt, 60 Hz cords have NEMA 6-20P plugs. This is a cord-connected unit, and must be on a separate power supply. Check the dataplate for the voltage, ampacity and maximum fuse size and per the dataplate use fuses or HACR circuit breakers.
Initial Start Up 1. Remove left front louver. Check machine for any packing or wires rubbing moving parts. Note location of control board at the left. 2. Switch the on off switch to On. 3. Switch on the electrical power to the machine. Observe that some of the control’s indicator lights glow and its display shows O .
Adjustments Bridge Thickness - For the Service Tech Only 1. Remove left louver, locate controller on and off switches. 2. Push and hold Off till the machine stops. 3. Remove curtain. 4. Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
Use and Operation Once started, the ice machine will automatically make ice until the curtain is held open by the ice at the top of the pile. The typical ice level when the machine is off will be several inches below the door sill. When ice level drops from use or meltage, the ice machine will resume making ice.
Control Switches There is a front on and off switch, located in the top center of the louvers. Switching this switch Off will immediately stop the machine. Switching it back on will cause the machine to restart in a timed harvest cycle. When that cycle is complete, normal ice making will resume.
Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • Remove the build up of mineral scale from the ice machine ’s water system and sensors. • Sanitize the ice machine ’s water system and the ice storage bin.
14. Locate ice thickness sensor. Squeeze mounting legs together to release sensor. Wash the metal surfaces of the sensor and the adjustment screw with ice machine scale remover solution. Also wash the water distributor and curtain with the ice machine cleaner solution.
What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature. • Controller self test failure. Check the following: 1.
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway, Vernon Hills, IL 60061 800-533-6006 www.scotsman-ice.com 17-3234-01.
デバイスScotsman Self Contained Cuber CU1526の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Scotsman Self Contained Cuber CU1526をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはScotsman Self Contained Cuber CU1526の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Scotsman Self Contained Cuber CU1526の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Scotsman Self Contained Cuber CU1526で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Scotsman Self Contained Cuber CU1526を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はScotsman Self Contained Cuber CU1526の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Scotsman Self Contained Cuber CU1526に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちScotsman Self Contained Cuber CU1526デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。