FM200 ® MODEL FT FIRE EXTINGUISHERS INST ALLA TION INSTRUCTIONS OWNER’S MANUAL THIS MANUAL IS AN INTEGRAL P AR T OF THE SYSTEM AND AS SUCH, THE EXTINGUISHER MUST BE INST ALLED AND MAINT AINED ACCORDINGL Y . READ AND COMPL Y WITH THESE INSTRUCTIONS, W ARNINGS AND LIMIT A TIONS BEFORE INST ALLING.
W ARNING CONCENTRA TED AGENT AND BY-PRODUCT OF APPLICA TION TO FIRE ARE T OXIC. A VOID BREA THING OF FUMES OR PROLONGED EXPOSURE. ACCIDENT AL DIS- CHARGE MA Y OCCUR DURING HANDLING OR INST ALLA TION OF THIS DEVICE, READ AND COMPL Y WITH INSTRUCTIONS, WARNINGS, AND LIMIT A TIONS CONT AINED IN THIS MANUAL.
REMINDER: Sea-Fire systems shall be considered as supplementary to the number of portable fire extinguishers required on-board and are designed and intended for enclosed unoccupied compartment installations that are not subject to direct weather or water .
OTHER APPLICA TIONS • Engine Compartments (maximum 150 cubic feet) • Bow Thrusters • Small Generator Set Enclosures • Consoles • Electrical Enclosures • Flammable Liquid Storage Areas • Pump Enclosures • Alternative Fuel Storage Areas In case of a fire and system discharged, the electrical supply to the motor must be discon- nected.
Figure 5 Step 8 Secure the detection tubing to the bulkhead by using the clips and screws supplied. Nylon wire ties may be used in lieu of the clips and screws.
Figure 6 THE FT EXTINGUISHER INST ALLA TION IS COMPLETE. INDICA TOR LIGHT OPERA TION All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light and escutcheon. ‘‘The U.S. Coast Guard approval requires an indicator light if this unit is installed for the protection of a boat’s engine compartment.
ELECTRICAL SWITCH INDICA TOR LIGHT GROUND IN-LINE FUSE IGNITION IGNITION SWITCH ST ARTER BA TTERY Figure 9 Figure 3 WHILE MAKING ELECTRICAL CONNECTION CAN RESUL T IN INJUR Y FROM FIRE OR ELECTRICAL BURNS. The indicator light is rated for 12 VDC (contact factory for other voltages).
Before operating the protected vessel, visually inspect pressure gauge for compliance and ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica- tor light is extinguished, remove, and replace the system immediately .
CONDITIONS All Sea-Fire products are tested after manufacture and shipped in perfect working order . Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of which is the sole responsibility of the consignee for which the total compensatory award will be limited to that appropriated by the carrier .
ALL FT (STINGER) MODELS ARE APPROVED FOR VERTICAL MOUNTING ONL Y . INTENDED OPERA TING TEMPERA TURE RANGE : 32°F –130°F (0°C – 54°C ) ST ANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1. ONE TUBING KIT , P ART # 130-121 – 10 FOOT TUBE OR 130-122 – 15 FOOT TUBE.
FG/FD/FT/MD/R/C-MODEL Fire Extinguisher MSDS No. SF002 MA TERIAL SAFETY DA T A SHEET Section 1 — Company and Chemical Identification MET ALCRAFT/SEA-FIRE MARINE EMERGENCY PHONE: 1-800-535-5053 9331-A PHILADELPHIA ROAD PHONE: 1-800-445-7680 BAL TIMORE, MARYLAND 21237DA TE: NOVEMBER 10, 2005 http://www .
Section 7 — Handling and Storage Handle, transport and store carefully and securely to avoid accidental knocking over or other severe physical impacts.
Section 15 — Regulatory Information U.S. Federal Regulations: The components of this product are either on the TSCA Inventory or exempt (i.e. impurities, a polymer complying with the exemption rule at 40 CFR 723.
SEA-FIRE MARINE SEA-FIRE EUROPE L TD Division of Metalcraft Inc. Unit 7. io Centre. Stephenson Road 9331-A Philadelphia Road Fareham, Hampshire Baltimore, Maryland 21237 USA PO15 5RU, United Kingdom Website: www .
デバイスSea-Fire FM200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sea-Fire FM200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSea-Fire FM200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sea-Fire FM200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sea-Fire FM200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sea-Fire FM200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSea-Fire FM200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sea-Fire FM200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSea-Fire FM200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。