SeagateメーカーLyrion Seriesの使用説明書/サービス説明書
ページ先へ移動 of 40
Product Manual Ly r i o n S e r i e s C E - A T A 100441950 Re v . A Ma y 2008 ST76021 1CA ST730212CA.
Revision history Copyright © 2008 Seagate T echnology LLC. All right s reserved. Printed in U.S.A. Publication number: 100441950, Rev . A May 2008 Seagate, Seagate T echnology an d the W ave logo ar e registere d trademarks of Seagate T echnology LLC in the United S tate s and/or other countrie s.
Lyrion CE-ATA Product Ma nual, Rev. A i Contents 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Disclaimer . . . . . . . . . . . . . . . . . .
ii Lyrion CE-ATA Product Manual, Rev. A.
Lyrion CE-ATA Product Manual, Rev. A iii List of Figures Figure 1. Lyrion Series (CE-ATA int erface) disc drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2. Typical 3.3V startup and operat ion current profile .
iv Lyrion CE-ATA Product Manual, Rev. A.
Lyrion CE-ATA Product Ma nual, Rev. A 1 1.0 Introduction This manual describes the functional, mechanical a nd interface specifications for the following Seagate ® Ly r io n ® Series CE-A T A drives: • ST76021 1CA-60GB, ST730212CA-30GB disc drives with a CE-A T A interface.
2 Lyrion CE-ATA Pro duct Manual, Rev. A 1.1 Disclaimer Seagate T echnology LL C makes no warranties what soever , including any warranty of merc hantabili ty , non- infringement, fitness for any particular pu rpose, or any warra nty otherwise ar ising out of any pro posal, specification or sample.
Lyrion CE-ATA Product Ma nual, Rev. A 3 2.0 Drive specifications Unless otherwise noted, all specific ations are me asured unde r ambient conditions, at 25°C, and nominal power . For convenience, the phrase s the drive and this drive are used throughout this m anual to indica te ST76021 1CA and ST730212CA model drive s.
4 Lyrion CE-ATA Pro duct Manual, Rev. A Performance idle power (typical 3.3V) 0.68 W Low power id le power (typical 3 .3V) 0.48 W S t andby/Sleep power (typical 3.
Lyrion CE-ATA Product Ma nual, Rev. A 5 2.2 Formatted cap acity LBA mode addressing When addressing these d rives in LBA mode, all bloc ks (sectors) are consecutively numbered from 0 to n–1, where n is the number of guara nteed sectors as defined abo ve .
6 Lyrion CE-ATA Pro duct Manual, Rev. A 2.4 Recording and interface tec hnology 2.5 Physical characteristics 2.6 Time to rea dy T echnology Specification Interface CE-A T A Recording method Perpendicu.
Lyrion CE-ATA Product Ma nual, Rev. A 7 2.7 Power specifications The drive receives DC power (+3.3V) throug h the ZIF conn ector (CE-A T A interface). 2.
8 Lyrion CE-ATA Pro duct Manual, Rev. A * Maximum is the average of t he peak value in 10 msec window 2.7.1.1 T yp ical current profile Figure 2. T ypical 3.3V startup and operation cur rent profile T able 2: DC power Power Consumption at 3.3V A verage (W) S tartup (max*) 1.
Lyrion CE-ATA Product Ma nual, Rev. A 9 2.7.2 Conducted noise Input noise ripp le is measured at th e host system powe r supply across an equivalent 15-ohm resistive load o n the +3.3 volt line. Using 3.3-volt power , the drive is expect ed to operate with a ma ximum of 70 m V peak-t o-peak squa re-wave injected nois e at up to 20 MHz.
10 Lyrion CE-ATA Product Manual, Rev. A 2.7.4 Po wer-manage ment mod es The drive provides pro grammable power man agement to pr ovide gr eater energy ef fici ency . The drive features the following power-ma nagement modes: • Active mode The drive is in Active mode during the r ead/write and seek operations.
Lyrion CE-ATA Product Ma nual, Rev. A 11 2.8 Environment al specifications 2.8.1 Ambie nt temperat ure Ambient temperature is defined as th e temperature of the envi ronment immed iatel y surrounding the d rive. Actual drive cas e temperat ure should not e xceed 70°C (158°F) within the operatin g ambient conditions.
12 Lyrion CE-ATA Product Manual, Rev. A 2.8.5 Shoc k All shock measurement s in this section are carried out at drive level. For all linear sh ock test, operating or nonoperating, th e input shock level is measured at the fra me of the d rive at the specif ic lo cation as indicated i n Figure 3 below .
Lyrion CE-ATA Product Ma nual, Rev. A 13 2.8.6.1 Operating sweep sine vibration The following lists the maximum operat ing sweep sine vibration levels that the drive may experience while meeting the performa nce standa rds s pecified. It consists of a forwar d and backward sweep from 10 Hz to 500 Hz to 10 Hz.
14 Lyrion CE-ATA Product Manual, Rev. A 2.8.6.4 Nonoperating random vibration The test consi sts of 15 minutes of ra ndom vibration using the power spectral density (PSD) levels specified in the table b elow . The vibration test level is 3.01 Gs RM S.
Lyrion CE-ATA Product Ma nual, Rev. A 15 2.9 Acoustics Drive acoustics are measured a s overall A-weighted a c oustic sound power levels (no pur e tones). Discrete tone penaltie s are added to the A-w eighted so und powe r (L W) with the following formula on ly when determin- ing compliance: L Wt(spec) == L W + 0.
16 Lyrion CE-ATA Product Manual, Rev. A 2.1 1 Reliability Measurement type Specification Nonrecoverable read errors 1 per 10 14 bits read, max. Load/Unload (LUL) cycles 300,000 software-controlled 20,.
Lyrion CE-ATA Product Ma nual, Rev. A 17 2.12 Agency certification 2.12.1 Safety certification The drives are re cognized in accordan ce with UL 60950 -1, CAN/CSA-C22.
18 Lyrion CE-ATA Product Manual, Rev. A 2.12.4 China Restriction of Hazardous Subst ances (RoHS) Directive This product has an Environ mental Protection Us e Period (EPUP) of 20 years.
Lyrion CE-ATA Product Ma nual, Rev. A 19 If necessary , you should consult your dealer or an ex perie nced radio/television technician for additiona l sug- gestions. Y ou ma y find helpful the following booklet prep ared by the F ederal Communications Commission: How to Identify and Resolve Radio-T elevision Interference Problems .
20 Lyrion CE-ATA Product Manual, Rev. A.
Lyrion CE-ATA Product Ma nual, Rev. A 21 3.0 Configuring and mounting the drive This section contains the specif ications an d instructions for configuring and mounting the drive.
22 Lyrion CE-ATA Product Manual, Rev. A • Do not remove the factory-in stalled labels from the drive or cover th em with a dditional labels. Removal voids the warranty. Some factory-in stalled labels contain information needed to service the d rive.
Lyrion CE-ATA Product Ma nual, Rev. A 23 3.2 Drive inst allation See Figure 7 for dr ive mechanical dimen sions. Follow these inst allation precautio ns when inserting the drive: • Follow instructions for the installation of data storage devices , provided with your device’s user man ual.
24 Lyrion CE-ATA Product Manual, Rev. A Figure 8. Lyrion Series FPC dimensions 3.3 Mounting considerations • Use an elas tic mountin g material t o protect d rives so as to ensure that more shock can be absorbed. • There are g uides along the side for mou nting.
Lyrion CE-ATA Product Ma nual, Rev. A 25 4.0 Interface description The drives use the CE-A T A interface. 4.1 Interface signals and connec tor pins The following table summarizes the signals o n the 18-w ay ZIF CE-A T A interf ace connec tor .
26 Lyrion CE-ATA Product Manual, Rev. A 4.2 Supported command set a nd features This section descri bes the MMC level commands support ed by the drive followed the supp orted reduce d A T A command set and a de scription of the sup ported S tatus and Control Registers (SCR).
Lyrion CE-ATA Product Ma nual, Rev. A 27 Identify Device command The Identify Device co mmand returns a single block of dat a (512 bytes or 256 wor ds) to the host, the relevant contents per th e CE-A.
28 Lyrion CE-ATA Product Manual, Rev. A 4.2.3 Status and Control Re gisters The S tatus and Control Register s (SCR) start at MMC reg i ster address 80h and can be accesse d only by using CMD60 (RW_ MUL TIPLE_REGISTER) to read or write to them.
Lyrion CE-ATA Product Ma nual, Rev. A 29 5.0 Seagate T echnology support services Internet For information regarding Se agate products and ser vices, visit www .sea gate.com . Worldwide support is available 24 hours da ily by email for your questions.
30 Lyrion CE-ATA Product Manual, Rev. A Customer Service Operations W a rranty Service Seagate of fers worldwide customer support for Seagate product s. Seagate d istributor s, OEMs and ot her direct customers should contact their Seagate Customer Serv ice Operations (CSO) re presentative for wa rranty- related issues.
Lyrion CE-ATA Product Ma nual, Rev. A 31 Index A acoustics 1 5 Active m ode 10 agency certification (regulatory) 17 altitude 11 ambient cond itions 3 ambient temperature 11 areal density 1 , 6 ATA com.
32 Lyrion CE-ATA Product Manual, Rev. A nominal po wer 3 nonopera ting random vibration 14 nonoperating sh ock 1 , 12 Nonoperating sweep sine vibration 13 nonrecoverable re ad errors 16 O Operating ra.
.
Seagate T echnology LLC 920 Disc Drive, Scotts V alley, Ca lifornia 95066-4544, USA Publication Number: 100441950 , Rev . A, Printed in U.S .A..
デバイスSeagate Lyrion Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Seagate Lyrion Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSeagate Lyrion Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Seagate Lyrion Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Seagate Lyrion Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Seagate Lyrion Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSeagate Lyrion Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Seagate Lyrion Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSeagate Lyrion Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。