SeaLandメーカーVacuum Pumpの使用説明書/サービス説明書
ページ先へ移動 of 12
1 Dometic Corporation 13128 S tate Rt 226, P .O. Box 38 Big Prairie, Ohio 4461 1-0038 USA SeaLand Product Hotline 1-800-321-9886 (8:00 a.m. - 5:00 p.m.
2 TABLE OF CONTENTS W ARNING: When using this product, always exercise basic safety precautions including the following: • Read all instructions before use or installation. • Never connect this product to any electrical circuit other than the specified voltage, and never exceed the amperage draw specified in “Electrical Wiring” on page 3.
3 Electrical Wiring It is imperative that adequate wire size and proper over-current protection (fuse or circuit breaker) sizes are used. The following chart can be used as a guideline. Refer to chart on page 10 for solenoid/relay information. 12 VDC 24 VDC 32 VDC 1 15 V AC (1 phase) 230 V AC (1 phase) 6 to 8 ga.
4 4. Disconnect electrical source to motor , following lock-out/t ag-out procedure. 5. Remove the six (6) 5/16" fasteners around the circumference of the pump top. 6. Carefully remove the pump top from the pump body . 7. Turn the pump top upside down to expose the diaphragm and rod bolt.
5 3. Install and adjust first hex nut for proper bushing clearance of 0.020" [.50mm]. 4. Hold adjustment nut from turning and install and tighten the lock nut. 5. Recheck bushing clearance. IMPORT ANT : INADEQUA TE CLEARANCE OR LOOSE LOCK NUT WILL CAUSE THE ECCENTRIC T O BIND, RESUL TING IN PUMP ST ALLING AND PREMA TURE BUSHING WEAR.
6 G . MOTOR REPLACEMENT T o Remove: 1. Turn off electrical power to pump. 2. Remove access plate from wiring junction box on motor . 3. Unhook wiring from motor leads. 4. Remove the four (4) motor mounting bolts securing the motor to the speed (gear) reducer .
7 TROUBLESHOOTING W ARNING Before attempting to open or service the pump: 1. If possible, flush pump with clean water and disinfectant. 2. Allow motor to cool if overheated. 3. Disconnect power supply to pump before servicing unit. Follow proper lock-out/tag-out procedures.
8 DIMENSIONALSPECIFICA TIONS WIRING DIAGRAMS M-Series V acuum Pump Wiring Schematic (V acuFlush System) NOTE : V acuum t ank pressure switches are wired in parallel for multiple toilet inst allations.
9 PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 310537 310538 342812 342813 342814 342815 342816 342817 342818 341792 342820 342821 342822 342823 341797 340704 Seal and Gasket Kit Bearing and Race Kit Inpu.
10 12VDC SOLENOID 24VDC SOLENOID 32VDC SOLENOID 1 15V AC RELA Y 50/60 HZ 220V AC RELA Y 50/60 HZ 345831 346900 346530 341431 342478 345831 346900 346530 342479 342478 Parts Below Not Shown 1/2HP 3/4HP.
11 PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 342469 341598 342422 342466 342770 342454 340689 640286 340720 342413 342472 342759 342.
12 MANUF ACTURER’S ONE-YEAR LIMITED WARRANTY SeaLand warrants to the original purchaser only , that this product, if used for personal, family or household purposes, is free from defects in material and workmanship for a period of one year from the date of purchase.
デバイスSeaLand Vacuum Pumpの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SeaLand Vacuum Pumpをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSeaLand Vacuum Pumpの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SeaLand Vacuum Pumpの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SeaLand Vacuum Pumpで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SeaLand Vacuum Pumpを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSeaLand Vacuum Pumpの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SeaLand Vacuum Pumpに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSeaLand Vacuum Pumpデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。