OWNERS MANUAL MODEL NO. 625.349290 CAUTION Read All Safety Guides Before You Start to Install Your Dispensing System SAVE THIS MANUAL -- HOW TO INSTALL- - HOW IT WORKS- - CARE OF- -- SPECIFICATIONS -- -- REPAIR PARTS-- Sears, Roebuck and Coo, Chicago, IL 60684 U.
TABLE OF CONTENTS PAGE NO, PAGE NO. Safety Guides ........................................ 3 What Does The Dispensing System Do ....... 3-4 Tools and Materials Needed ......................... 5 Put The System Together ........................ 6 Locating and Solution Injecting .
I SAFETY GUnDES A Read all steps, guides and rules carefully before installing and using your new Solution Dispensing System. Follow all steps exactly to correctly install. Failure to follow them could cause personal injury or property damage. Reading this book will also help you to get all of the benefits from your dispensing system.
WHAT YOUR SOLUT OI water softener, installed on the outlet side of the pressure tank, filters and softens the water If you do not like a remaining chlorine taste, Sears has taste and odor filters to r.
TREATING WELL WATER PRE-TREATING PRIVATE WELL SYSTEMS HAVING IRON BACTERIA -- Before you put the dispensing system together and install it, chlor- inate the well if it contains more than 10 parts per million (ppm) of bacterial iron. Use the following steps.
PUT YOUR DISPENSING 1, Fasten the solution pump to the base with 4 nylon screws and nuts, as shown 2. Working through the tank fill hole, assemble the Low Level Indicator to the tank as shown, Positon the upper window port so the red indicator is easily seen_ 3.
WHERE TO LOCATE YOUR Locate the system where... ......a 115 volt, 60 Hz electrical power source is nearby. (See page 11) ...good fresh air flow will cool the solution pump motor and carry away solution fumes. ..... the area is clean and the air is free of dust.
I BLENDING TANK BLENDING TANK 42 ga! minimum -- separate inlet & outlet -- no air bag or diaphragm Pressure Tank Well I i I ' ,ill i BLENDING TANK 42 gal minimum -- separate inlet & outle.
GUBDES TO BNSTALL YOUR S (_) SOLUTION INJECTION INTO THE ALTERNATE DISCHARGE FITTING ON THE WELL PUMP 1. Turn off the electrical power to the well pump and turn off the gas or electric supply to the water heater 2. Open a faucet for a few seconds, to bleed off water pressure, then close 3.
I GUIDES TO _) SOLUTION INJECTION BETWEEN THE WELL PUMP AND PRESSURE TANK 1. Turn off the electrical power to the well pump and turn off the gas or electric supply to the water heater, 2. Open a faucet for a few seconds to bleed off water pressure, then close 11.
ELECTRICAL WgRRNG GUIDE, € A CAUTION: DO NOT TRY TO DO ANY WIRING IF YOU DO NOT KNOW ELEC- TRICITY. CALL A GOOD ELECTRICIAN A CAUTION: DO NOT DO ANY WIRING ON LIVE CIRCUITS ALWAYS TURN OFF THE ELECTRICAL POWER AT THE SOURCE, NOTE: All wiring must follow local or national electrical codes.
I RLL THE TANK WnTH THE SOLUTION DISPENSING SYSTEM RESER- VOIR (TANK) HOLDS 15 GALLONS OF SOLUTION. HOWEVER, ON THE FIRST FILL, ALLOW SOME ROOM IN THE TANK SO THE SOLUTION STRENGTH CAN BE CHANGED IF NEEDED. DE- PENDING ON THE WATER PROBLEM YOU ARE TREATING, FILL THE TANK AND SET THE FEED RATE AS FOLLOWS.
I RLL THE TANK WroTH SOLUT 1. Residual still above 0.6, and the feed control knob at 1 or 2-- Use less chlorine in the mixture For example, use 1 gallon of bleach for each 2 gallons of water instead of 1 to 1 2.
FILL THE TANK WnTH 3. Turn the relief-release valve (clockwise only FIG. 11, page 12) to the open position_ Solution is pumped through the suction tubing, into the pump head, then returned to the tank (takes 3-5 minutes).
KEEP YOUR DaSPENSUNG RESERVOIR (TANK) SOLUTION LEVEL -- After installing the solution dispensing system, check the solution level in the tank daily. Red shows in the Low Level Indicator when about 5 gallons of solution remains. After awhile, you will know about how much solution it uses each day and how often to refill the tank.
I KEEPYOUR DUSPENSnNG LUBRICATION -- At least every 6 months, lubricate the solution pump as follows: 1. Unplug the electrical power cord, 2. Loosen the set screw in the feed control knob and remove the knob and bushing, 3. Remove the pump top cover, 4.
KEEP YOUR D SPENSING If the dispensing system is exposed to the sun, replace the solution tubing every6 months. Re- place the tubing yearly if the system is installed indoors.
27 26 25---'- MODEL NO. 625.349290 9 ! 16 RETURN I / m -N m.
PARTS LiST MODEL NO. 625.349290 NO. 1 2 4 5 6 7 8 9 10 11 KEY PART NUMBER 818405 818399 818510 8800650 U0812612 818382 811704 811703 8800418 814211 8800702 12 812318 13 816342 14 L98013_-188 15 810036 16 U0816093 8800710 17 818544 18 8800470 DESCRIPTION Float Assembly Pipe, Low Level Indicator Tank Cap Tank, 15 Gal.
S AI S OWNERS MANUAL SERVICE MODEL NO. 625.349290 HOW TO ORDER REPAIR PARTS TELL SEARS YOU WANT IT INSTALLED THEN RELAX (F642-5289) Now that you have purchased your Solution Dispensing System, should .
デバイスSears 625.34929の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sears 625.34929をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSears 625.34929の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sears 625.34929の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sears 625.34929で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sears 625.34929を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSears 625.34929の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sears 625.34929に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSears 625.34929デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。