COIN-OPERATED COMMERCIAL ELECTRIC DRYER OWNER'S MANUAL and INSTALLATION INSTRUCTIONS SEARS, ROEBUCK AND CO. Hoffman Estates,IL 60179 www.sears.com TABLE OF CONTENTS Dryer Safety ............................................................ 2 Installation Instructions .
DRYER SAFETY YOUR SAFETY AND THE SAFETY OF OTHERS IS VERY IMPORTANT. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
INSTALLATION Three-Wire Electrical Connection to Receptacle INSTRUCTIONS Read the "Dryer Safety" section of this Owner's Manual and completely read these Installation Instructions before beginning installation. IMPORTANT: Observe all governing codes and ordinances.
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
The dryer can be connected directly to fused disconnect or circuit breaker box with three-wire, flexible armored or non-metallic sheathed copper cable (with grounding wire). All current-carrying wires must be insulated. A conduit connector must be installed at junction box.
Alternate Connection: Four-Wire Electrical Connection to Receptacle If local codes do not permit the connection of a frame- grounding conductor to the neutral wire: 1. Disconnect power. 2. Make sure the power supply cord or direct wire cable is in place.
Local codes may permit the useof a U.L.-listed, 120/240-volt minimum, 30 ampere, dryer power supply cord kit (pigtail). Power supply cord should be type SRD or SRDT andbe at least four feet long. The wires that connect to the dryer must end with ring terminals or spade terminals with turned ends.
Four-Wire Electrical Connection Direct Wire) 1. Disconnect power. • Strip 5 inches of outer covering from end of cable. Leave bare grounding wire at 5 inches. Fire Hazard Use 10 gauge solid copper wire. Use a UL approved strain relief. Disconnect power before making electrical connections.
5. Connect neutral grounding wire andthe neutral wire (white or center) of direct wire cable under the center screw of terminal block. Center silver-colored terminal block screw External ground Neutral wire (white) connector / II dL II ,arece,,er w re I III ".
Use duct tape to sealalljoints. Do not use screws to secure vent.Lintmay catch on screws. Use 4-inch diameter heavy metal or flexible metal vent. Do not kink or crush flexible metal vent. It must be fully extended to allow adequate exhaust air to flow.
Multiple dryer exhausting guide Many multiple-family dwellings are furnished with pro- visions in the building for washing and drying laundry with automatic washers and dryers. The exhausting of the individual clothes dryers can be accomplished with a central exhaust vent system.
Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. Excessive Weight Hazard Use two or more people to move and install dryer.
Installing coin-slide mechanism NOTE: If the coin-slide mechanism is installed, skip this step and proceed to coin-box adjustment. Remove the service door from the meter case by unlock- ing the service lock with the key shipped with the dryer. Carefully insert coin-slide mechanism into opening and guide into holes.
Replacing nylon timing cams on accumulator mechanism Electrical Shock Hazard Disconnect power before servicing. Replace all panels before operating, Failure to do so can result in death or electrical shock.
9. Set new vend price by adding or removing the appropriate block-out keys and/or dime inserts according to Table of Vend Prices. TABLE OF VEND PRICE VENO COIN BLOTB PRICm IRa4nSTn o IIIIIIII lo¢u1111111 25¢11DIIIII 35¢DIDIIIII 5o¢IIDDIIII 8o¢ DIDDIIII 75¢IIDDDIII 85¢ DIDDDIII =I.
To close dryer top: 1. Push down on top until front locks catch. 2. Relock security top lock with key. 3. Replace screws under lint lid. 4. Replace tee spacer and nut on stud inside meter case. 5. Replace timer and bracket in meter case. Tighten mounting screws.
TROUBLESHOOTING Before servicing the dryer, always check out the machine to substantiate the complaint for which the service call was created. In many cases, it may just be a customer-instruct problem. Will not run • Power supply Check line fuses and line switches.
Troubleshooting (cont.) Drying temperature too high • Operating thermostat Check for lint that may insulate thermostat from exhaust air. Check thermostat for function. Motor runs with door open • Door switch Check door switch for function and switch clip actuating arm for proper switch plunger actuation.
19.
For major brand repair service: Call 24 hours a day, 7 days a week 1-800-4-MY-HOM EsM (1-800-469-4663) Para pedir servicio de reparacibn a domicilio - 1-800-676-5811 For the repair or replacement parts you need: Call 6 a.
デバイスSears Clothes Dryerの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sears Clothes Dryerをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSears Clothes Dryerの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sears Clothes Dryerの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sears Clothes Dryerで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sears Clothes Dryerを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSears Clothes Dryerの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sears Clothes Dryerに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSears Clothes Dryerデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。