Seiko Groupメーカー9T82Aの使用説明書/サービス説明書
ページ先へ移動 of 8
1 [SPECIFICATIONS] Cal. No. Item 9T82A Movement (x 1.0) Additional mechanism • Automatic generating system • Stopwatch function with stopwatch hour, minute, second and 1/10 second hands • Overch.
2 P ARTS CA T ALOGUE Disassembling procedures Figs. : 1 → 12 Reassembling procedures Figs. : 12 → 1 Lubricating: Types of oil Oil quantity SEIKO Watch Oil S-6 Normal quantity Silicone oil 500,000 c.s. Adhesive (LOCTITE 241) ➡ Please see the page shown after the part name.
3 P ARTS CA T ALOGUE Cal. 9T82A 11 Stopwatch hour and minute hands (page 7) 12 Dial (page 7) 9 Stopwatch 1/10 second hand (page 7) 10 Stopwatch second hand (page 7) 8 Hour, minute and second hand (page 6) ➡ Please see the page shown after the part name.
4 TECHNICAL GUIDE Cal. 9T82A 1 Case back · To fix the case back to the case, the case back itself is screwed into the case, or the case back screws are used, depending on models. · For the models using the case back screws, use the adhesive “LOCTITE 241” to prevent them from loosening.
5 TECHNICAL GUIDE Cal. 9T82A Lubricating: : Silicone oil 500,000 c.s. 5 Winding stem with crown • Lubricating Apply the silicone oil to the portion of the crown as indicated in the illustration at right. Insert the winding stem into the stem pipe, and turn the crown so that the silicone oil is spread thoroughly over the crown gasket.
6 TECHNICAL GUIDE Cal. 9T82A Lubricating: : SEIKO Watch Oil S-6 3 Bezel gasket Never apply the silicone oil to the bezel gasket. Otherwise, the silicone oil may spread to the dial or other parts, causing malfunctions.
7 TECHNICAL GUIDE Cal. 9T82A 9 Stopwatch 1/10 second hand 10 Stopwatch second hand 11 Stopwatch hour and minute hands • How to install 1. Reset the stopwatch to “00”. When the stopwatch is properly reset to “00”, the hammer appears in the eyehole “A” as shown below.
8 TECHNICAL GUIDE Cal. 9T82A II. VALUE CHECKING AND ADJUSTMENT ● Resetting the stopwatch hands to “0” position ● Checking the time period of date change Repeat “START” – “STOP” – “RESET” of the stopwatch several times to check if each of the three stopwatch hands returns to “0” position securely.
デバイスSeiko Group 9T82Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Seiko Group 9T82Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSeiko Group 9T82Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Seiko Group 9T82Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Seiko Group 9T82Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Seiko Group 9T82Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSeiko Group 9T82Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Seiko Group 9T82Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSeiko Group 9T82Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。