CV - P0 9 FX R PORT ABLE TYPE ROOM AIR CONDITIONER INST ALLA TION AND OPERA TION MANUAL CLIMA TISEUR DE CHAMBRE DE TYPE PORT A TIF MANUEL D’INST ALLA TION ET D’UTILISA TION *P lasmacluster is a trademark of SHARP Corporation. * Plasmacluster est une marque de commerce de SHARP Corporation.
.
ENGLISH ENGLISH This manual explains the proper use of your new air conditioner . Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS • FOR CUSTOMER ASSISTANCE (U.S.) .
E-2 FOR CUST OMER ASSIST ANCE (the United States) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
ENGLISH E-3 CONSUMER LIMITED W ARRANTY CONSUMER LIMITED W ARRANTY FOR THE U.S. USERS SHARP ELECTRONICS CORPORA TION warrants to the first consumer purchaser that this Sharp brand product (the “Produ.
E-4 FOR CUST OMER ASSIST ANCE (Canada) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
ENGLISH E-5 LIMITED W ARRANTY Consumer Electronics Products Congratulations on your purchase! Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to .
PRECAUTIONS Points to keep in mind when using your air conditioner . W ARNINGS FOR USE • Install the air conditioner in accordance with the installation instructions in the latter section of this manual. •D o not modify any part of this product. •D o not insert anything into any part of the unit.
ENGLISH E-7 W ARNING ABOUT GROUNDING •I mproper use of the grounding plug can re- sult in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of an electric shock by providing a less resistant conduit for the electric current.
PRECAUTIONS NOTES ON OPERA TION •A llow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety .
ENGLISH LOCA TION • The air conditioner should be placed on a firm founda- tion to minimize noise and vibration. For safe and se- cure positioning, place the unit on a smooth, level floor strong enough to support the unit. • The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces.
P ART NAMES 1 Air Outlet 2 Vertical louvers 3 Horizontal louvers 4 PLASMACLUSTER Lamp (blue) 5 Remote control signal receiver window 6 AUX. Button 7 OPERATION Lamp (red) 8 TIMER Lamp (orange) 9 MEGA COOL Lamp (green) 0 Air inlet REAR VIEW NOTE: Actual unit might vary slightly from above illustration.
ENGLISH REMOTE CONTROL 1 Transmitter 2 Display 3 POWER Button 4 LIGHTS Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 1 hr OFF Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER But.
INST ALL WINDOW P ANEL Hole Projection Insect guard net Rain guard "A" Window panel Projection "A" Window panel E-12 Adjustment panel Exhaust cover Window panel Foam seal A (adhesive type) Installation in a double-hung sash window (See page 14 for installation in a sliding sash window.
ENGLISH Adjustment panel Extension panel Foam seal E-13 If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window frame width.
INST ALL WINDOW P ANEL Installation in a sliding sash window (See page 12 for installation in a double-hung window.) Hole Projection Insect guard net Rain guard "A" Window panel Projection "A" Window panel E-14 Adjustment panel Exhaust cover Window panel 1 Connect the rain guards to the insect guard net.
ENGLISH If the inner height of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to fit the window frame height. (3) Secure the window panel to the window frame with 3 screws.
Exhaust hose Window exhaust adapter Projection Extend Hole "TOP" E-16 The exhaust hose must be installed or removed in accordance with the usage mode.
ENGLISH n dow h aust a pter "PUSH" Projection E-17 Removal of the exhaust hose 1 Remove the window exhaust adapter . Pull out and remove the window exhaust adapter by pushing down two “PUSH” markings, and slide and close the exhaust cover in the window panel.
1 Remove the battery cover at the back of the remote control. 2 Insert batteries into the compart- ment, making sure the ± ± ± ± ± and — — — — — polarities are correctly aligned. • Lines will appear on the display when batteries are properly in- stalled.
ENGLISH E-19 CAUTION •D o not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary , close the curtains to block out the sunlight. •U se of a fluorescent lamp in the same room may interfere with transmission of the signal.
1 3 COOL MODE Drainage nozzle Stopcock E-20 Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 Press the MODE button to select COOL mode. COOL DEHUM FAN VENT 2 Press the POWER button to start op- eration.
ENGLISH DEHUMIDIFICA TION MODE 1 Remove the exhaust hose (See Page 17) 2 Turn the drainage nozzle to the OPEN position. 3 Pull the stopcock out from the drainage nozzle. • When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.
F AN MODE 1 5 2 3 VENTILA TION MODE 1 4 5 2 3 E-22 Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. Install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.
ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be changed. Hold the vertical louver as shown in the dia- gram and adjust the air flow direction. 1 Press the LOUVERS button on the re- mote control.
1 Press the PLASMACLUSTER button during operation. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light. TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off.
ENGLISH 1 Press the MEGA COOL button during cooling mode. • The remote control will display " " . • The temperature display will go off. • The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. • MEGA COOL operation is also cancelled when the mode is changed, or when the unit is turned off.
0.5h 1.0h 1.5h 10h 1 1h 12h E-26 NOTES ON TIMER SETTING AND OPERATION • The latest time setting will be memorized and will appear on the remote control display the next time you set the OFF TIMER or ON TIMER. • The OFF TIMER and ON TIMER can not be set together.
ENGLISH E-27 1 ON TIMER Display shown when you set the unit to turn on 6.5 hours later. The unit will turn on automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.
AUXILIAR Y MODE AUXILIAR Y MODE 1 E-28 Use this mode when the remote control is not available. 1 Press the AUX. button on the unit. • The red OPERATION lamp on the unit will light and the unit will start operating in COOL mode. • The fan speed is set to AUTO.
ENGLISH DRAINAGE Prepare for drainage and drain out water within the unit in the following cases. If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that the water tank inside the unit is full.) 1 Make sure to turn the unit off.
CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any residue by wiping with a damp cloth and dry completely . A void splashing water onto the unit. W ater can dangerously damage the electrical insulation.
ENGLISH BEFORE CALLING FOR SER VICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NOT OPERA TE A T ALL • Is the unit plugged.
デバイスSharp CV -P09FXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharp CV -P09FXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharp CV -P09FXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharp CV -P09FXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharp CV -P09FXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharp CV -P09FXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharp CV -P09FXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharp CV -P09FXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharp CV -P09FXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。