SharpメーカーCV-P09FRの使用説明書/サービス説明書
ページ先へ移動 of 22
ENGLISH C V - P 09F R R * Plasmacluster is a trademark of SHARP Corporation. FRANÇAIS • Uses ozone layer friendly refridgerant R410A. • Verwendet das die Ozonschicht schonende Kühlmittel R410A. • Utilise un réfrigérant qui n’attaque pas la couche d’ozone, le R410A.
A. Information on Disposal for Users (p rivate households ) 1. In the European Un ion Attention: If you w ant to dispose of this equipment, please do not use the ordinary dust bin! Used electrical a n.
ENGLISH ENGLISH This manual e xplains the proper use of your ne w air conditioner . Please read this manual carefully bef ore using the product. This manual should be kept in a saf e place f or handy reference. CONTENTS E-1 • IMPORTANT SAFETY INSTRUCTIONS .
USAGE CAUTIONS • V entilate the room periodicall y during use , especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance or cleaning. • Do not splash or pour water directly onto the unit.
ENGLISH E-3 ENERGY EFFICIENCY TIPS • A void direct sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode. • Keep the filter clean. K eeping the filter clean greatly aids efficient operation. A dir ty filter bloc ks the flow of air , making your air conditioner work harder and less effi- ciently .
P AR T NAMES 1 Air Outlet 2 Vertical louvers 3 Horizontal louvers 4 PLASMACLUSTER Lamp (blue) 5 Remote control signal receiver window 6 AUX. Button 7 OPERATION Lamp (red ) 8 TIMER Lamp (orange ) 9 TURBO COOL Lamp (green ) 0 Air inlet REAR VIEW NOTE: Actual unit might vary slightly from above illustration.
ENGLISH REMOTE CONTROL 1 Transmitter 2 Display 3 ON/OFF Button 4 DISPLAY Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 1 hr OFF Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER B.
1 Remove the battery cover at the back of the remote control. 2 Insert batteries into the com- partment, making sure the ± ± ± ± ± and — — — — — polarities are correctly aligned. • Lines will appear on the display when batteries are properly in- stalled.
ENGLISH E-7 CAUTION • Do not e xpose the signal receiver window to direct sunlight. This may adv ersely aff ect its operation. If necessar y , close the cur tains to block out the sunlight. • Use of a fluorescent lamp in the same room may interfere with transmission of the signal.
The exhaust hose must be installed or removed in accordance with the usage mode. Mode Exhaust hose COOL, F AN, VENTILA TION Install DEHUMIDIFICA TION Remove Installation of the exhaust hose 1 Attach the insect guard net to the ex- haust adapter .
ENGLISH 1 3 COOL MODE Drainage nozzle Stopcock E-9 Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 4 2 3 “CLOSE position” 1 Press the MODE button to select COOL mode.
DEHUMIDIFICA TION MODE E-10 7 6 In this mode, the air conditioner dehumidifies the room. Drainage nozzle Stopcock Hose clamp Hose 1 Remove the exhaust hose (See Page 8) 2 Turn the drainage nozzle to the OPEN position. 3 Pull the stopcock out from the drainage nozzle.
ENGLISH F AN MODE 1 5 2 3 VENTILA TION MODE 1 4 5 2 3 E-11 Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.
T O CHANGE AIR FLOW DIRECTION UP/DOWN AIR FLOW DIRECTION NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be changed. Hold the vertical louver as shown in the dia- gram and adjust the air flow direction. 1 Press the SWING button on the remote control.
ENGLISH E-13 1 Press the TURBO COOL button during cooling mode. • The remote control will display “ ” . • The temperature displa y will go off. • The green TURBO COOL lamp ( ) on the unit will light. T O CANCEL Press the TURBO COOL button again.
0.5h 1.0h 1.5h 10h 1 1h 12h E-14 NOTES ON TIMER SETTING AND OPERATION • The latest time setting will be memorized and will appear on the remote control display the next time you set the OFF TIMER or ON TIMER. • The OFF TIMER and ON TIMER can not be set together.
ENGLISH E-15 1 ON TIMER Display shown when you set the unit to turn on 6.5 hours later. The unit will turn on automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.
AUXILIAR Y MODE AUXILIAR Y MODE 1 E-16 Use this mode when the remote control is not available. 1 Press the AUX. button on the unit. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in COOL mode. • The fan speed is set to AUTO.
ENGLISH DRAINAGE Prepare for drainage and drain out water within the unit in the following cases. If the unit stops operating and the TIMER ( ), OPERATION ( ) and TURBO COOL ( ) lamps are blinking. (This indicates that the water tank inside the unit is full.
CLEANING THE UNIT AND THE REMO TE CONTROL Wipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any residue b y wiping with a damp cloth and dr y completely . A void splashing water onto the unit. W ater can dangerously damage the electrical insulation.
ENGLISH BEFORE CALLING FOR SER VICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NO T OPERA TE A T ALL • Is the unit plugge.
ENGLISH SHARP CORPORA TION Osaka, Japan TINSEA419JBRZ 05AO TH 1 Printed in Thailand R.
デバイスSharp CV-P09FRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharp CV-P09FRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharp CV-P09FRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharp CV-P09FRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharp CV-P09FRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharp CV-P09FRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharp CV-P09FRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharp CV-P09FRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharp CV-P09FRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。