ENGLISH E-1 ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. • IMPORTANT SAFETY INSTRUCTIONS ..... E-1 • ADDITIONAL NOTES ON OPERATION ............. E-3 • TIPS ON SAVING ENERGY .
IMPORT ANT SAFETY INSTRUCTIONS CAUTIONS FOR USE 1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock.
ENGLISH INDOOR TEMP. OUTDOOR TEMP. COOLING upper limit 32 ˚ C D.B. 43 ˚ C D.B. 23 ˚ C W.B. - lower limit 21 ˚ C D.B. 21 ˚ C D.B. 15 ˚ C W.B. - HEATING upper limit 27 ˚ C D.B. 24 ˚ C D.B. - 18 ˚ C W.B. lower limit 20 ˚ C D.B. -7 ˚ C D.B. - -8 ˚ C W.
P ART NAMES 1 Outlet (Air) 2 Vertical Adjustment Louvres 3 Horizontal Adjustment Louvres 4 Indicator Panel 5 Air Filters 6 Intake Grille 7 Inlet (Air) 8 Remote Control 9 OPERATION Lamp (red ) 0 TIMER Lamp (orange ) q PLASMACLUSTER Lamp (blue) w RECEIVER Window e AUX.
ENGLISH REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 ON/OFF Button 5 THERMOSTAT Button 6 FULL POWER Button 7 MODE Button 8 ONE-HOUR OFF TIMER Button 9 TIMER.
1 Remove the remote control cover. 2 Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00" when batteries are prop- erly installed. 3 Reinstall the cover. USING THE REMOTE CONTROL E-6 NOTES: • The battery life is approximately one year in normal use.
ENGLISH E-7 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
SWING FAN MODE SET/C 1h Press the THERMOSTAT button to set the desired temperature. • In the AUTO and DRY modes, the tem- perature can be changed in 1°C incre- ments within the range of 2°C higher to 2°C lower from the temperature auto- matically determined by the air conditioner.
ENGLISH E-9 During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. MODE CHANGEOVER During seasons when you need COOLING at dayti.
E-10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION HOW TO ADJUST THE AIR FLOW DIRECTION HEAT mode COOL and DRY modes The adjustment range is narrower the SWING range in order to prevent con- densation from dripping. The range is wide so the air flow can be directed toward the floor.
ENGLISH E-1 1 FULL POWER OPERA TION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. 1 Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”.
1 Press the TIMER OFF ( ) button. 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
ENGLISH 1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
E-14 1 TIPS ABOUT PLASMACLUSTER OPERA TION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold.
ENGLISH MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry.
CLEANING THE FIL TERS E-16 MAINTENANCE The air filters should be cleaned every two weeks. 1 TURN OFF THE UNIT 2 OPEN THE INTAKE GRILLE 1 Slide the stoppers to the left ( OPEN ). Two stoppers are provided for each the intake grille. 2 Gently pull and open the intake grille.
ENGLISH IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL Check whether the remote con- trol batteries have become old and weak. Try to send the signal again with the remote control pointed prop- erly towards the unit’s signal re- ceiver window.
SHARP CORPORA TION OSAKA, JAPAN TINSEA417JBRZ TH 05D- 1 Printed in Thailand GS-XP07FR_Eng.p65 05.4.1, 4:42 PM 20.
デバイスSharp GS-XP07FRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharp GS-XP07FRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharp GS-XP07FRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharp GS-XP07FRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharp GS-XP07FRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharp GS-XP07FRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharp GS-XP07FRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharp GS-XP07FRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharp GS-XP07FRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。