GP ™ Silent Air Purifier Germicidal Protection SI871 Instructions INCLUDES IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
.
Dear Sharper Image Customer , Thank you for your purc hase of a Sharper I mage prod uct. W e a pprecia te your business very much. Our goal is that you will be completely satisf ied with this product’ s quality and performance. W e offer generous return privileges and excellent warranties on all our products.
.
W arnings ................................................................................... 6 Caution ..................................................................................... 8 F requently Asked Questions ...............................
W arnings W arning: T o reduce the risk of fire, electric shock or injury when using any electrical appliance, basic precautions should always be observed, including the following: • This appliance operates at 110V AC and 50Hz or 60Hz only . • Connect to a polarized outlet only .
or against sharp edges or corners. • K eep the cord away from heated surfaces. • A damag ed p ower cord must be r epla ced b y qu alifie d se rvi ce per sonn el on ly .
This product generates invisible ultraviolet light. T o avoid overex - posure when the lamp is on, persons must stay at least one foot away from the unit if the total duration of exposure to the unit will be more than 30 minutes per day . Shorter duration of expo- sure at close proximity is safe.
F requently Asked Questions How often is cleaning required? At least every two weeks, anytime The Sharper Image ® GP™ Silent Air P urifier makes an audible sound or the Cleaning Overdue indicator illuminates. How should it be cleaned? Wipe the removable collection grid with a damp cloth, paper towel or sponge.
F requently Asked Questions About OzoneGuard ™ What does OzoneGuard™ do? With the OzoneGuard in place, a significant portion of ground- level ozone inside the air purifier — including any trace levels of ozone by-product — is converted into oxygen before the cleaned air circulates back into the room.
General Instructions Setup and Operation Place The Sharper Image GP at least twelve inches from the wall and in a location where children cannot stare directly into the unit at a close range. Plug into a polarized 110V outlet. (Read W arnings for details.
Setup and Operation Switch the MODE CONTROL to the desired setting: L OW: F or small rooms or rooms where the door is usually closed. MEDIUM: F or average -sized rooms. HIGH: F or large rooms and higher traffic areas. T o override the MODE CONTROL setting and to run the unit at maximum power for five minutes, press BOOST .
Cleaning the Collection Grid This model features 3 highly charged collection blades separated by 2 oppositely charged “ driver ” blades. This improves the particle capture rate. Cle an t he gr id ev ery one o r tw o wee ks. As a remin der , th e Cleaning Overdue in dica tor t urns ambe r aft er t wo we eks.
Cleaning the Collection Grid 3. Use a dry or slightly damp towel or sponge to quickly wipe the dust from each of the three collection bars. 4. Before replacing the grid, invert the entire unit two or three times. Note: The grid may also be washed with warm soapy water , then rinsed.
Thorough Cleaning 3. Use a hair dryer to blow dust from the interior or a vacuum to remove dust. Note: The OzoneGuard cannot be detached from the front grill. The OzoneGuard has sharp edges; use caution when cleaning . CAUTION: Do not use the product if the ionizing wires are broken or either grill appears damaged.
Additional Information The majority of collected particles will gather on the removable stainless steel grid. Over time, debris will accumulate inside the unit. T o access the inside, remove the front and rear grills. (See section titled “Thorough Cleaning .
Germicidal Lamp Replacement Oil from fingers will reduce the germicidal performance of the UV - C lamp. If possible, use gloves or handle only by the metal area of the lamp. Otherwise, clean the lamp after installing to remove fingerprints and oils.
18 WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user ’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to P art 15 of the FCC R ule s.
19 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver . • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for assistance.
One-Y ear W arranty What Is Covered This warranty covers any defects in materials or workmanship, with the exceptions stated below . How Long Coverage Lasts This warranty runs for one year from the date of original purchase.
デバイスSharper Image SI871の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sharper Image SI871をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSharper Image SI871の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sharper Image SI871の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sharper Image SI871で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sharper Image SI871を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSharper Image SI871の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sharper Image SI871に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSharper Image SI871デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。