SIMA TIC 505-2571 Program Port Expander User Manual Order Number: PPX:505–8131–1 Manual Assembly Number: 2806135–0001 Original Edition.
! DANGER DANGER indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury . DANGER is limited to the most extreme situations. ! W ARNING W ARNING indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury , and/or property damage.
MANUAL PUBLICA TION HISTOR Y SIMA TIC 505-2571 Pr ogram Port Expander User Manual Or der Manual Number: PPX:505-8131-1 Refer to this history in all correspondence and/or discussion about this manual.
LIST OF EFFECTIVE P AGES Pages Description Pages Description Cover/Copyright Original History/Effective Pages Original iii — vii Original 1-1 — 1-5 Original 2-1 — 2-6 Original 3-1 — 3-3 Origin.
Contents iii Contents Chapter 1 PPX:505-2571 Module Description Module Featur es 1- 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 2 Installing the Module 2.
iv Contents List of Figures 1-1 PPX:505-2571 Pr ogram Port Expander Module 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Process Monitoring Application Using PCs 1-4 . . . . . . . . . . . . . . . . . . . . . . .
Contents v List of T ables 2-1 Baud Rate Switch Settings 2-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 T roubleshooting Matrix 4-4 . . . . . . . . . . . . . . . . . . . . . . .
Preface vii Manual T itle Preface This user manual provides installation and operation instructions for the SIMA TIC 505-2571 Program Port Expander Module for Series 505 programmable controllers. W e assume you are familiar with the operation of Series 505 programmable controllers.
505–2571 Module Description 1-1 SIMA TIC 505-2571 Program Port Expander Manual Chapter 1 PPX:505-2571 Module Description Module Featur es 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
505–2571 Module Description 1-2 SIMA TIC 505-2571 Program Port Expander Manual The PPX:505-2571 Program Port Expander Module is a member of the communication family of I/O modules for the Series 505 programmable controllers.
505–2571 Module Description 1-3 SIMA TIC 505-2571 Program Port Expander Manual As control systems become more complex and dispersed, the demand for attaching serial devices has increased.
505–2571 Module Description 1-4 SIMA TIC 505-2571 Program Port Expander Manual More sophisticated applications may require the monitoring of a large number of variables in the controller .
505–2571 Module Description 1-5 SIMA TIC 505-2571 Program Port Expander Manual Using a notebook PC running the SIMA TIC TISOFT application, a maintenance engineer can easily make changes in the controller program or adjust timer and/or drum preset values.
Installing the Module 2-1 SIMA TIC 505-2571 Program Port Expander Manual Chapter 2 Installing the Module 2.1 Getting Started 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Module 2-2 SIMA TIC 505-2571 Program Port Expander Manual 2.1 Getting Started The installation of the PPX:505-2571 Programming Port Expander Module consists of the following steps: 1. Planning the installation. 2. Installing the module into the I/O base.
Installing the Module 2-3 SIMA TIC 505-2571 Program Port Expander Manual The baud rates for each port may be individually set via DIP switches. In addition, for the RS–232 ports (1 and 2) you can enable or disable hardware handshaking. The PPX:505-2571 is shipped with all DIP switches in the OFF position.
Installing the Module 2-4 SIMA TIC 505-2571 Program Port Expander Manual Getting Started (continued) Hold the top and bottom of the bezel and slide the module carefully into the slot, pushing it all the way into the base.
Installing the Module 2-5 SIMA TIC 505-2571 Program Port Expander Manual If you require hardware handshaking for flow control, you should refer to the device documentation for information on connecting the RTS, CTS, DCD, DTR, and DSR lines. The PPX:505-2571 RS–232 port is configured as DTE.
Installing the Module 2-6 SIMA TIC 505-2571 Program Port Expander Manual Getting Started (continued) In Figure 2-3, the PPX:505-2571 module is installed into slot 1 and I/O base 0. For your particular installation, look in the chart at the slot address occupied by the module in your configuration.
Module Operation 3-1 SIMA TIC 505-2571 Program Port Expander Manual Chapter 3 Module Operation Effect of Controller Scan T ime 3-2 . . . . . . . . . . .
Module Operation 3-2 SIMA TIC 505-2571 Program Port Expander Manual The PPX:505-2571 is designed to work with operator interface devices which adhere to the Non–Intelligent T erminal Protocol (NITP). Up to four supported devices may concurrently communicate with the controller .
Module Operation 3-3 SIMA TIC 505-2571 Program Port Expander Manual The requests are processed during the discrete portion of the controller scan (refer to Chapter 1 of the SIMA TIC 545/555/575 System Manual for a discussion of the timeline).
T roubleshooting 4- 1 SIM A TIC 505-2571 Program Port Expander Manual Chapter 4 T roubleshooting Module Malfunction 4- 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication s Signal Pr oblems 4- 2 .
T roubleshooting 4-2 SIMA TIC 505-2571 Program Port Expander Manual When power is applied to the PPX:505-2571, it first performs a Power On Self T est (POST) to determine if all module components are operating properly . This test takes only a few seconds.
T roubleshooting 4- 3 SIM A TIC 505-2571 Program Port Expander Manual If the XMT indicator does not flash within 2 seconds of receiving a signal (RCV indicator flashes), it indicates that the PPX:505-2571 is not responding to the signal. Refer to the information below for possible causes.
T roubleshooting 4-4 SIMA TIC 505-2571 Program Port Expander Manual T able 4-1 T r oubleshooting Matrix Symptom Probable Cause Corrective Action Active Indicator light not on. 1. No Power to module 2. Defective module 1. Ensure 5V power is supplied to the rack 2.
Specifications A-1 SIMA TIC 505-2571 Program Port Expander Manual Appendix A Specifications T able A-1 Physical and Envir onmental Specifications Number of Concurrent Communications Ports 4 Serial Por.
Customer Response We would like to know what you think about our user manuals so that we can serve you better . How would you rate the quality of our manuals? Excellent Good Fair Poor Accuracy Organiz.
BUSINESS REPL Y MAIL FIRST CLASS PERMIT NO.3 JOHNSON CITY , TN FOLD FOLD POST AGE WILL BE P AID BY ADDRESSEE NO POST AGE NECESSARY IF MAILED IN THE UNITED ST A TES A TTN: TECHNICAL COMMUNICA TIONS M/S.
.
デバイスSiemens 505-2571の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Siemens 505-2571をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSiemens 505-2571の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Siemens 505-2571の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Siemens 505-2571で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Siemens 505-2571を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSiemens 505-2571の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Siemens 505-2571に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSiemens 505-2571デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。