SiPass integrated AFI5100 Installation manual Fire Safety & Security Products Siemens Building Technologies.
Liefermöglichkeiten und tec hnische Änderungen vorbehalten. Data and design subject to change without not ice. Supply subject to availability. © 2005 Copyright by Siemens Building Technologies AG Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor.
Contents 1 Input Point Modul e (AFI5100) ................................................................ 5 1.1 Product Descr iption ................................................................................... 5 1.2 Product Numbers ............
4 Siemens Building Technologies Fire & Security Products 02 .200 5.
Input Point Module (AFI5100) 1 Input Point Module (AFI5100) Fig. 1 Input Point Module 1.1 Product Description The AFI5100 is an Input Point Module used as part of a Siemens integrate d access control and security solution.
Input Point Module (AFI5100) 1.4 Expected Installation Time 30 minutes 1.5 Mounting Instructions 1. Remove the AFI5100 from its carton and discard the packa ging material. 2. Place the AFI5100 (base-plate) agai nst the surface to which it is to be affixed and mark the location of the mounting holes.
Input Point Module (AFI5100) 4. Connect the next device in the Fire Override sequence to the FIRE OVER- RIDE OUTPUT port if required. 5. Connect the FLN wires (from the ACC) to the RS485 BUS port. 6. If the FLN cable is long or subject to high noise, ensu re that the jumper across link LK10 (EOL) has been made.
Input Point Module (AFI5100) The following diagram displays the location of the port s on the AFI5100 : FOR OUT Nc C No OUT 1 Nc C No OUT 2 Nc C No OUT 3 Nc C N o OUT 4 Nc C No DC POWER IN 0V V+ E LOC.
Input Point Module (AFI5100) 1.7 Links and Jumpers The following table outlines the link settings for th e AFI5100 : Link Description Value LK1, LK2 Links 1 and 2 are used to configure whether Fire Over-ride (FOR) will oper- ate in Enhanced FOR mode or Normal.
Input Point Module (AFI5100) 1.8 LEDs The following table describes the operatio n of the LEDs located on the AFI5100 : LED Brief Description POWER The POWER led is illuminated when power has been applied to the device.
Input Point Module (AFI5100) 1.9 Recommended Cable Specifications The following table outlines the cable re commended for connection of an inte- grated security system: Recommended Cable Specifica tio.
Input Point Module (AFI5100) 12 Siemens Building Technologies A24205-A335-B245.doc Fire Safety & Security Products 02.2005.
.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.sbt.siemens.com © 2005 Copyright by Siemens Building Technologies AG Data and design subject to change without notice. Supply subject to availability.
デバイスSiemens AFI5100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Siemens AFI5100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSiemens AFI5100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Siemens AFI5100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Siemens AFI5100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Siemens AFI5100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSiemens AFI5100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Siemens AFI5100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSiemens AFI5100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。