Copyright 1998 by Siemens AG C79000-Z7076-C552-01 Supplement to the STEP 7 User Manual V4.0 New Functions in V ersion 4.02 Contents Page 1 Overview 2 2 Creating and Editing Projects 3 3 Configuring Ha.
New Functions in V ersion V4.02 2 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 1 Overview New and Modified Functions in STEP 7 V ersion 4.02 The information in this supplement will familiarize you with the additional functions of STEP 7, version 4.
New Functions in V ersion V4.02 3 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 2 Creating and Editing Projects New Function: Password Protection for Access to Programmable Controller.
New Functions in V ersion V4.02 4 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 3 Configuring Hardware New CPU Parameters There are many new components in version 4.02; for example, racks, C7 control systems, or CPUs in the hardware catalog.
New Functions in V ersion V4.02 5 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Improved Display and Print Functions The changes to the display and print functions are listed below in detail, with a brief description of how each function can be used.
New Functions in V ersion V4.02 6 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring the ET 200X (BM 147/CPU) as a DP Slave The BM 147/CPU basic submodule is configured as an intelligent DP slave.
New Functions in V ersion V4.02 7 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring the DP/P A Link The DP/P A link is a DP slave which for its part (acting as a kind of “master”) “opens” a PROFIBUS P A for connecting PROFIBUS P A devices.
New Functions in V ersion V4.02 8 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Configuring Software Redundancy The configuration of a “warm standby” system consists of: T wo S7 stations with one PROFIBUS-DP master interface each (each of these interfaces forms its own subnet).
New Functions in V ersion V4.02 9 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Creating a Catalog Profile If the hardware catalog supplied with STEP 7 is too large or too dif ficult for you to use, you can create your “own” catalog.
New Functions in V ersion V4.02 10 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 4 Configuring Networks and Connections Configuring Connections while Configuring a Network The application for configuring networks can also be used to configure connections.
New Functions in V ersion V4.02 11 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Connecting an S7-200 to the Multipoint Interface If you wish to connect an S7-200 to the MPI subnet (in addition to programming devices, operating panels, or S7-300/400s), you must select a transmission rate of 19.
New Functions in V ersion V4.02 12 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Effects on Existing Programs If you have been using this criterion to distinguish between different sy.
New Functions in V ersion V4.02 13 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 Parameters which Differ from One Another Only in their Use of Upper and Lower Case Characters Conflict: Source files containing such interfaces can no longer be compiled without errors.
New Functions in V ersion V4.02 14 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 6 Creating User Programs Operation New menu command Edit Select All : The effect depends on the context in which the command is used (see online help).
New Functions in V ersion V4.02 15 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 7 Displaying Reference Data New Menu Command: Filter and Display Y ou can use this menu command to call up the reference data and to set the filters before the reference data are displayed.
New Functions in V ersion V4.02 16 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 9 Debugging User Programs Programming LAD/STL/FBD S7 Blocks: T est Environment for Debugging in Program Status The execution of test functions is dependent on the mode of operation set (process operation or test operation).
New Functions in V ersion V4.02 17 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 New Functions: Forcing with S7-300 Modules The following table provides an overview of the functions and summarizes the differences between forcing and modifying.
New Functions in V ersion V4.02 18 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 10 Diagnosing Hardware New Function: Diagnosing Hardware – Quick View In the SIMA TIC Manager you ca.
New Functions in V ersion V4.02 19 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01 12 Printing Improved Print Functions in the SIMA TIC Manager Y ou can use the menu command File Print Object List to print a list of the selected objects on the default printer .
New Functions in V ersion V4.02 20 Supplement to the STEP 7 User Manual V4.0 C79000-Z7076-C552-01.
デバイスSiemens C79000-Z7076-C552-01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Siemens C79000-Z7076-C552-01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSiemens C79000-Z7076-C552-01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Siemens C79000-Z7076-C552-01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Siemens C79000-Z7076-C552-01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Siemens C79000-Z7076-C552-01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSiemens C79000-Z7076-C552-01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Siemens C79000-Z7076-C552-01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSiemens C79000-Z7076-C552-01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。