Isolated Multi-Dr op ™ Converter Operator’ s Manual Manual No. SG-6048-01 LOGO Isolated Multi-Drop™ Po r t 1 Tx Rx Po r t 4 Tx Rx Po r t 3 Tx Rx Po r t 2 Tx Rx RS485 RS485 RS485 RS485.
The use of unauthorized parts in the repair of the equipment o r tam- pering by unqualified pe rsonnel will r esult in danger ous conditions which may cause sever e personal injury or equipment damage. Follow all safety instructions contained her ein.
Contents Siemens Energy & Automation, Inc. 1 Introduction ........ ................... ....... 1 1.1 Product S ummary......... ...... ....... ...... ....... ... 1 1.2 How to Use This Manual .... ............. .......... 1 2 Setting Up the Converter .
1 Intr oduction Siemens Energy & Automation, Inc. 1 1 Introduction 1.1 Pr odu ct Summary The Siemens Isolated Multi-Dr op TM conver t er is an electr onic device that lets you connect your DO S-based PC to the Siemens SEAbus TM communications network for ACCESS TM devices o n your power distribution system.
2 Setting Up the Converter 2 Siemens Energy & Automation, Inc. 2 Setting Up th e Conver ter 2.1 Ove rvie w Before connecting the converter to y our system, understand the connectors, LEDs and switches.
2 Setting Up the Converter Siemens Energy & Automation, Inc. 3 . Figure 2.4 Rear Panel The BAUD thumbwheel switch selects the data rate for communications. Set the data rate to be consistent with the data rate for your system’ s S EAbus communications network.
3 Installing th e Converter 4 Siemens Energy & Automation, Inc. 3 Installing the Converter 3.1 Getting Ready This section explains how to install the Isolated Multi-Drop converter for your operation. Y ou can install t he converter either dir ectly to a PC or r emotely within switchgear using short-haul or dial-up modems.
3 Installing the Converter Siemens Energy & Automation, Inc. 5 3.3 Connecting Directly to a PC T o connect the Isolated Multi-Dr op converter dir ectly to a PC, you need an RS-2 32 serial cable of not more than 50 feet in length. Make sure the cable is a DCE-DTE cable, not a null modem cable .
3 Installing th e Converter 6 Siemens Energy & Automation, Inc. 3.4 Connecting wit h Short-Haul Modems If the distance between your PC and Isolated Multi-Dr op converter is gr e ater than 50 feet but less than 3.5 miles, you can connect them using short-haul modems and regular telephone cable.
3 Installing the Converter Siemens Energy & Automation, Inc. 7 3.5 Connecting wit h Dial-Up Modems If the distance between your PC and Isolated Multi-Dr op converter is gr eater than 3.
4 T esting ACCESS Devices 8 Siemens Energy & Automation, Inc. 4 T esting ACC ESS Dev ices Y ou can use the Isolated Multi-Dr op converter’ s 15 VDC power output to pr ovide DC power for testing Static T rip III trip units or SAMMS devices.
4 T esting ACCESS Devices Siemens Energy & Automation, Inc. 9 4.3 T esting Static T rip III on Desktop If you are testing a Static T rip III trip unit on a desktop, follow these steps to connect the trip unit to t h e converter for 15 VDC power , while re f erring to Figur e 4.
4 T esting ACCESS Devices 10 Siemens Energy & Automation, Inc. Figure 4.4 Connecting SAMMS Device for T esting T wo-wire cable RS-485 cable rear panel front panel 15VDC OUT + - RS485 + _ + _ RS485.
5 T r ou bleshootin g Siemens Energy & Automation, Inc. 11 5 T roubleshooting If you exper ience communications errors and suspect the Isolated Multi-Dr op converter i s at fault, perform the actions listed below . Before performing these tests: 1.
5 T r ou blesh ooting 12 Siemens Energy & Automation, Inc. NOTE S:.
Appendic es Siemens Energy & Automation, Inc. 13 Appendix A: Block Diag ram The illustratio n below is a block diagram showi ng how the Isolated Multi-Dr op converter operates. The diagram identifies the internal components that make up the converter .
Appendices 14 Siemens Energy & Automation, Inc.
Appendic es Siemens Energy & Automation, Inc. 15 Appendix B: M ounting Dimensions The illustration below shows the mounting dimensions for the Iso lated Multi-Drop conv erter . Use these dimensions to muont the converter to a switchgear panel or to some other location.
Appendices 16 Siemens Energy & Automation, Inc.
Siemens Ener gy & Automat i on, Inc. Switchgear and Motor C ontrol Business P .O. Box 2950 3 Ralei gh, NC 2762 6-0503 Manual No. SG- 6048-01 (Replaces -0 0) 1M 0595FP Printed in U.
デバイスSiemens ISOLATED MULTI-DROP SG-6048-01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Siemens ISOLATED MULTI-DROP SG-6048-01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSiemens ISOLATED MULTI-DROP SG-6048-01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Siemens ISOLATED MULTI-DROP SG-6048-01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Siemens ISOLATED MULTI-DROP SG-6048-01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Siemens ISOLATED MULTI-DROP SG-6048-01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSiemens ISOLATED MULTI-DROP SG-6048-01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Siemens ISOLATED MULTI-DROP SG-6048-01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSiemens ISOLATED MULTI-DROP SG-6048-01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。