1450digexport REV 1/5/07 SER VICE MA NUAL (INTERN A TIO NAL) IMPING ER CONVEYOR O VENS MODEL 1433-000-E, 1434-000-E, 1456, 145 7 WITH PUSH BUTT ON CONTR OLS Lincoln Foo dservi ce Prod ucts, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.
Impinger I – Adv Digital – G as Service Manual – Intern ational 2 SEQUENCE OF OPERA TION IMPINGER A DV A NTAGE SERIAL NUMBER N28 654 AND ABOVE (OVENS WITH P USH BUTTON CONTROLS) MODEL 14 33-000-E 230VAC 50 HZ. NAT. GAS MODEL 14 34-000-E 230VAC 50 HZ.
Impinger I – Adv Digital – G as Service Manual – Intern ational 3 SCHEM ATIC DIAGR A M MO DEL 1433-000-E, 1 434-000-E SERI A L NUM BER N28654 TO N31348.
Impinger I – Adv Digital – G as Service Manual – Intern ational 4 SCHEM ATIC DIAGR A M MODEL 1456 , 1457 SERI A L NUM BER N28654 TO N31348.
Impinger I – Adv Digital – G as Service Manual – Intern ational 5 SCHEM ATIC DIAGR A M MO DEL 1433-000-E, 1 434-000-E, 14 56, 1457 SERI A L NUM BER N31349 AND A BOVE.
Impinger I – Adv Digital – G as Service Manual – Intern ational 6 TRO UBLESHOOTIN G GUIDE IMPING ER ADVANT AGE GAS OVEN S SERI A L NUM BER N28654 AND A BOVE (OVENS W ITH PUSH BUT TO N CONTROLS) SYMPTO M POSSIBLE CAUSE EVALUAT ION Oven fan wi ll not run Incom ing power suppl y Check circuit breaker, r eset if required.
Impinger I – Adv Digital – G as Service Manual – Intern ational 7 W ITH PO W ER OFF: Rem ove 3 prong plug (on gas valve) and m easure c ontinuity between t erminals 2 a nd 3. If no contin uity, check the following: Proper gas pressure s upply to gas v alve as m arked on the oven specificatio n plate.
Impinger I – Adv Digital – G as Service Manual – Intern ational 8 not sta y on, check the reset butt on for the ig nition control. If the above chec k oka y , replace ign ition control.
Impinger I – Adv Digital – G as Service Manual – Intern ational 9 there is volta ge to the pilot valve, but th ere is no gas pressure, r eplace gas val ve. Pilot tube Check for gas press ure at pilot tube. Disc onnect pilot tube at burner and connect manom eter.
Impinger I – Adv Digital – G as Service Manual – Intern ational 10 Oven control If the therm ocouple check s good, but th e oven contro l display indicat es that ther e is a therm ocouple failure, replace the oven contro l. If the oven contr ol indicates a temper ature reading, but th e oven will not heat, proce ed.
Impinger I – Adv Digital – G as Service Manual – Intern ational 11 sensor (s ensor is located in the conve yor motor). Measure vo ltage at the m otor connector, red wire and yellow wire. V oltage shou ld be approx. 1 0VDC. If no voltage is pr esent, trace wiring back to oven control.
Impinger I – Adv Digital – G as Service Manual – Intern ational 12 REMO VAL, INSTALL A TIO N & ADJUSTM ENTS IMPINGER A DVANTAGE SERIES CAUTION! BEFORE R EMOVING OR I NSTALLING ANY COMPO NENT IN T HE IMPINGER OVEN BE SU RE TO DISC ONNECT EL ECTRICAL P O W ER AND GA S SUPPLY MOTO R, MAIN FAN - REP LACEMENT 1.
Impinger I – Adv Digital – G as Service Manual – Intern ational 13 THERMOST AT, COO LING FAN - REP LACEMENT 1. Shut off power at m ain break er. 2. Remove contro l panel top a nd front cover. 3. Remove lead wires and m ark for r eassembly. 4. Remove two (2) s crews and rem ove therm ostat.
Impinger I – Adv Digital – G as Service Manual – Intern ational 14 8. Remove burner assem bly from housing, th e main and pilot orifice, f lame target, pil ot shield (main and ex tension), burn er ignitor can n ow be cha nged or service d as needed.
Impinger I – Adv Digital – G as Service Manual – Intern ational 15 THERMOST AT, OVEN C AVITY HI-LIM IT – REPLA CEMENT 1. Shut of f power at m ain breaker. 2. Rem ove control box c over and front panel. Rem ove conve y or ass embly and fingers from oven to aid in r emoval of therm ostat from oven.
Impinger I – Adv Digital – G as Service Manual – Intern ational 16 THERMOC OUPLE ME ASURMENT TEMPERAT URE D .C. MILLVOLT S (APPROX .) 200 ° 2.8 250 ° 4.0 300 ° 5.1 350 ° 6.0 400 ° 7.1 450 ° 8.2 500 ° 9.3 550 ° 10.4 600 ° 11.5 CONT ROL TRANSFO RMER - REPL ACEMENT 1.
Impinger I – Adv Digital – G as Service Manual – Intern ational 17 6. Remove assem bly and repl ace main orif ice. 7. Reassem ble in reverse ord er and check system opera tion. NOT E: Check all gas line f ittings f or leaks. PILOT O RIFICE - REPLA CEMENT 1.
Impinger I – Adv Digital – G as Service Manual – Intern ational 18 GENERAL VIEW ADVANTAGE SERIES LETT ER PART NUM BER DESCRIPT ION A 369003 Door hinge B 369110 Access wind ow assem bly C 369337 .
Impinger I – Adv Digital – G as Service Manual – Intern ational 19.
Impinger I – Adv Digital – G as Service Manual – Intern ational 20 CONTROL BOX 1456,1457,1 433-000-E, 1434-000-E LETT ER PART # DE SCRIPTION A 369062 Top, Contro l Panel B 370355 Oven Contro l C.
Impinger I – Adv Digital – G as Service Manual – Intern ational 21.
Impinger I – Adv Digital – G as Service Manual – Intern ational 22 OVEN BA CK ADVANTAGE SERIES GAS AND ELE CTRIC LETT ER PART NUM BER DESCRIPT ION A 369808 Cover, m otor (gas ovens) 3701 40 Cover, m otor (electric ovens ) B 369214 Motor, m ain fan (50 Hz.
Impinger I – Adv Digital – G as Service Manual – Intern ational 23.
Impinger I – Adv Digital – G as Service Manual – Intern ational 24 CONVEYOR 1450 SE RIES LETT ER PART NUMBER DESCRIPT ION 3698 30 Com plete conveyor assem bly A 369816 369163 Conve yor belt, com.
Impinger I – Adv Digital – G as Service Manual – Intern ational 25.
Impinger I – Adv Digital – G as Service Manual – Intern ational 26 This page in tentionally left blank..
Impinger I – Adv Digital – G as Service Manual – Intern ational 27 This page in tentionally left blank..
Impinger I – Adv Digital – G as Service Manual – Intern ational 28.
デバイスSigma 1456の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sigma 1456をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSigma 1456の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sigma 1456の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sigma 1456で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sigma 1456を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSigma 1456の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sigma 1456に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSigma 1456デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。