Reduced wiring system EX250 - SEN1 Instruction Manual EtherNet/IP™ Compatible SI Unit URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA.
Contents Thank you for purchasing the SMC reduced wiring system EX250 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference.
2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.
4 5 Pr oduct Summar y Power supply for Output Block (for high wattage load) 24VDC Connecting to bus at upper level (EtherNet/IP) Power supply for output/input and control 24VDC Solenoid valve Output B.
6 7 SI Unit Model Indication Method Ti e-rod (2 pcs.) Accessory Note1 : For wiring method, refer to subsection "Wiring" (page 12) in this manual. Note2 : For display and setting method, refer to subsection "Display/Setting" (page 15) in this manual.
8 9 Mounting/Installation (continued ) Layout of the Input Block Position the Input Block on the left side of the SI Unit. Layout of the EX9 series Output Block / Power Block Position the Output Block / Power Block on the right side of the SI Unit and between the SI Unit and solenoid valve or End Plate R (on the Output Block side).
10 11 Specifications Sensor input area 1 0 I/O mapping Offset (word) Input data MSB LSB MSB LSB 15 8 70 0 1 Input area mapping 15 14 L : Fixed to Low Item Status Condition SP Solenoid power supply sta.
12 13 Wiring 43 2 1 1 34 2 M12 1 2 +Rx 3 - Tx 4 - Rx 1 2 3 4 5 6 7 8 Shield RJ45 6.7 47.3 45 2000 Model No. : EX9-AC020EN-PSRJ +Tx Wiring diagram Cable core wire external color Terminal No.
14 15 Wiring ( continued ) 24VDC 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blue : 24VDC (for input and control) Black : 0V (for input and control) Cable P ar t No .
16 17 12345678 ON 1 0 IP address 192.168.0.X 1 0 1 0 1 0 1 2 0 0 1 1 1 1 3 0 0 0 0 1 1 4 0 0 0 0 1 1 Remote control * 1 X 3 2 1 14 DHCP mode * 2 SW1 Communication setting CLEAR/HOLD Manual set up of I.
18 19 Input Bloc k Model Indication Method EX250 IE Block type 1 2 3 Input points : 2, M12 connector (2pcs.) Input points : 4, M12 connector (2pcs.) Input points : 4, M8 connector (4pcs.) Input Block Model indication method Pa rt Names No. Part names Application 1 Input equipment connector Connects the input equipment such as sensor, etc.
20 21 Wiring EX250-IE3 EX250-IE1/2 EX250-IE1 (M12 connector, 5 pin, Socket) EX250-IE2 (M12 connector, 5 pin, Socket) *1) Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly input from the input connector "0".
22 23 Displa y/Setting EX250-IE1 EX250-IE2/IE3 0 0 1 1 EX250 EX250 0 0 1 1 2 2 3 3 EX250 EX250 Display Description PWR Lights up Power supply for sensor is ON. Off Power supply for sensor is OFF. 0, 1, 2, 3 Lights up Sensor signal input corresponding to the number is ON.
24 25 Pa rt Names T ie-rod (2 pcs.) Accessory T ie-rod (2 pcs.) Accessory W aterproof cap (for socket)(1 pc.) Dimensions ( unit : mm ) 59.8 72.6 21 Output Block 59.8 80.3 21 PWR PWR Po wer Bloc k Mounting/Installation Refer to subsection "Mounting/Installation" (page 7) in this manual.
26 27 Wiring ( continued ) Output connector pin lay out EX9-OET1, EX9-OEP1 (M12 connector, 5 pin, Socket) Output No.1 *1 Output No.0 NC *2 1 NC *2 3 GND 5 NC *2 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5.
28 29 Wiring ( continued ) M12 connector, 5 pin, Reverse key 1 Power supply for output (24VDC) 2 Power supply for output (0VDC) 5 Ground ( 3 Power supply for sensor (24VDC)) * ( 4 Power supply for sen.
30 31 Wiring ( continued ) Displa y Output Block PWR PWR Po wer Bloc k The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when the Power Block is positioned next to the SI Unit.
32 33 Option ( continued ) Waterproof Cap Mounted on the unused ports of the Input Block, Output Block and Power Block. The proper use of this Waterproof Cap can achieve IP67 Enclosure. (The Waterproof Caps are delivered together with the Power Block as accessories.
34 Tr oubleshooting ( continued ) MS LED status Normal status : Green light ON Fatal failure : Red light ON 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch.
デバイスSMC Networks EX9-AC -1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SMC Networks EX9-AC -1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSMC Networks EX9-AC -1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SMC Networks EX9-AC -1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SMC Networks EX9-AC -1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SMC Networks EX9-AC -1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSMC Networks EX9-AC -1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SMC Networks EX9-AC -1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSMC Networks EX9-AC -1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。