T igerAccess ™ EE Ether net-o ver -VDSL2 CPE ◆ High-speed Internet access ov er exis ting phone lines ◆ Concurrent data/p hone services ov er si ngle connecti on ◆ Alw a ys-on digi tal connect.
.
20 Mason, Irvine, CA 92618 Phone: (9 49) 679-8000 T igerAccess-EE CPE Installation Guide From SMC’ s T iger line of f eature-rich w orkgroup LAN so lutions February 2007 Pub.
Information fu r nished b y SMC Netw orks, Inc. (S MC) is believ ed to be accurate and r eliable. Howev er, no respon sibility is assumed by SMC for its use, nor for any inf ring ements o f patents or other righ ts of third par tie s whi ch m ay resul t fr om i ts u se.
i L IMITED W ARRANTY Limited W ar ranty Statement: SMC Ne tworks, Inc. (“SMC” ) warran ts its p roduct s to be free from defect s in workmanship and materials , under normal use and ser vice, for the applicable wa r ranty ter m.
ii WARRA NTIE S EXCLUSIV E: IF AN SMC PR ODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’ S SOLE REMED Y SHALL BE REP AIR OR REPLA CEMENT OF THE PR ODUCT IN QUESTION , A T SMC’S OPTI ON.
iii C OMPLIANCES FCC - C lass B This device complies with P art 15 of the FCC Rules . Operation is subject to the fol lowing two condit i ons: (1) This device may not cau se harmfu l interference , a nd (2) this device must accept any inter ference receiv ed, includ ing interference that may cause undesired operati on.
C OMPLIANCES iv If y our equipment causes harm to the telephone netw ork, the telephone company ma y discont inue your ser vic e temporari ly . If possible, the y will noti fy you in advance. But if advance notice is not practical, you will be notifi ed as soon as possible.
C OMPLIANCES v Wa r n i n g : Do not plug a phone jac k connector in the RJ-45 port. This may damage this device . Attention: Les raccor d eurs ne s ont pas utilisés pour le système téléphonique! .
C OMPLIANCES vi W ar nings and Caut ionar y M essa ges Wa r n i n g s (in German) En vir onmental Statement The manufacturer of this product endeav ours to sustain an en vironmentally-friendly policy throughout the entire production process .
C OMPLIANCES vii Manufacturing Materials There are no hazardous nor oz one-de pleting materials in this product. Documentation All printed documentation for this pr oduct uses biodegrad able paper that originates from sustained and managed forests. T he inks used in the printing process are non- toxic.
C OMPLIANCES viii.
ix T ABLE OF C ONTENTS 1 About the TigerAccess-EE CPE . . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 VDSL Techn ology . . . . . . . . . . . . . . . .
T ABLE OF C ONTENTS x Glossary Index.
1-1 C HAPTER 1 A BOUT THE T IGER A CCESS -EE C PE Overview This Ethernet-Ov er-VDSL2 CPE system consis ts of an end-us er CPE (Customer P remise Equipment) and a VDSL2 switch that are connected by s tandard te lephone cabl e.
A BOUT THE T IGE R A CCES S -EE CPE 1-2 MDF dis tribution eq uipment i nto the swit ch. The data and pho ne signals for ea ch user are co mbine d in th e swit ch, and passed over VDSL l ines to indi vidual customers .
VDSL T ECHNO LOG Y 1-3 VDSL Technology VDSL (V ery High Bit-Rate Digita l Subscriber Line) is at the high-e nd of all the D SL techn ologies , of fering t he best co mbination of fiber optics and copper to provi de high-speed broadband I nter net acce ss .
A BOUT THE T IGE R A CCES S -EE CPE 1-4 data rate in the do wnstrea m (receiv e) dire ction than in the upstre am (transmit) direction . VDSL delive rs high-perfor man ce onlin e applications, suc h as hig h-quality video and othe r switched multimedia ser vic es .
S YSTEM R EQUIREMENTS 1-5 • Supports ITU-T VDSL/V DSL2 and ANSI T1E1.4 Part 1 VDSL interface stan dards, as well as o ther evolving ETSI, ANSI, and ITU VDSL sta ndards for the copper local lo op •.
A BOUT THE T IGE R A CCES S -EE CPE 1-6 • Power requiremen ts: 12 VDC via the inclu ded AC power ada pter. Make su re th at a pr oper ly grou nded power outlet is with in 1.8 m (6 ft) of the CP E. • The CPE shou ld be located in a c ool dry place, wit h at least 5 cm (2 in.
2-1 C HAPTER 2 H ARDWARE D ESCRIPTION Unpacking After u npacking t his CPE, c heck the co ntents to be that su re you ha ve recei ved all the comp onents . Then, before begin ning th e installa tion, be sure t hat you have all ot her nece ssar y instal lation equip ment.
H ARDW ARE D ESCRIPTION 2-2 Front and Re ar Panel This device is an external VDSL2 CPE for high-speed In ternet access applic ations . The f ront panel o f the CPE pro vides an ar ray of system and port status indicators .
S YSTEM AND P ORT S TAT US LED S 2-3 System and Port Status LEDs The CPE inclu des key syst em and port indicat ions that simp lify insta llation and network tr oubles hooti ng . T he LE Ds , wh ich are locate d on the front panel for easy viewing, are desc ribed in the following table.
H ARDW ARE D ESCRIPTION 2-4.
3-1 C HAPTER 3 I NSTALL ATION Installa tion Overview Before installing the CPE, verify that y o u hav e all the items lis ted in the “Unpac king” on page 2-1. If any of the i tems are mi ssing or damaged, conta ct your local di stribu tor . Also , be sure you have all the n ecess ar y to ols and cabling before installi ng the CPE.
I NSTA LLATI ON 3-2 1. Using s tandard telephon e cable, c onnect th e CPE’ s RJ-11 LINE port to the RJ-11 telepho ne wall jack pro vidin g the VDSL ser v ice.
C ONFIGURING THE TCP/I P P RO T OC OL S 3-3 Conf iguring th e TCP/IP Protoc ols T o connect th e CPE to a com put er thr ough i ts Ether net por t, th e comput er must have an Ethe r net network adap ter car d installed , and be config ured for the TCP/I P prot ocol.
I NSTA LLATI ON 3-4 Windo ws XP 1. Click “ Star t/Con trol Pa n el/Net work Conn ections. ” 2. Right-click the “Local Ar ea Conn ection” icon for the adapter you wan t to co n fi g ur e. 3. Highligh t “Int er net Prot ocol (T CP/IP) . ” 4.
A-1 A PPENDI X A T ROUBLESHOOTING Diagnosi ng CPE Indicators CPE operation is eas ily monitored via the LED ind icators t o identify problems. The table below desc ribes commo n probl ems you may encoun ter and pos sible solu tions . If the solution s in the t able fail to resolv e the pr oblem, contact tec hnical support for advice.
T R OUBLESHOOTING A-2 If You Canno t Connect to t he Internet • Check that your computer is properly con figured for TCP/IP. See “Conf iguring th e TCP/IP Pr otocols” on page 3 -3. • Make sure t he correct net work adapter driv er is installe d for your operating sys tem.
B-1 A PPENDIX B C ABLES Twiste d-Pair Cable and Pin Assignmen ts F or 10B ASE-T and 100BASE-TX co nnections, th e tw isted-pair cable must have two pairs of wires. Each wire pair is ide ntifie d by two different colo rs . F or examp le, one w ire mi ght be g ree n and th e oth er, g reen w ith wh ite stripes .
C ABL ES B-2 10BASE-T/100BASE-TX Pin Assign ments Use unshielde d twisted-pair (UTP) or shielded twis ted-pair (STP) cab le for RJ-45 connections: 100-ohm Categ or y 3, 4 or 5 cable for 10 Mbps connections , or 100-ohm Categor y 5 cable for 100 Mbps connections .
T WISTED -P AIR C ABL E AND P IN A SSIGNMENTS B-3 Straight-Through W iring If twisted-p air cable is to join tw o ports and only one of the por ts has an inter nal cross over (MDI-X), the t wo pairs of wires must be straig ht-throug h.
C ABL ES B-4 Crossov er Wirin g If the t wisted-p air cable is to join two por ts and either both por ts a re labeled with an “X” (M DI-X) or neithe r por t is labeled with an “X” (MDI), a crossover must be imple mente d in the wi ring .
RJ-11 P OR TS B-5 RJ-11 Ports Standar d telephone RJ-11 connect ors and cab ling can be found in sev eral common wiring patt ern s . These si x-pin conn ectors can a ccommodate u p to three wir e-pairs (t hree tele phon e lines), bu t usually only one or two pairs of con ducto r pins and wi res ar e impleme nte d.
C ABL ES B-6 Table B-2 RJ-11 Port Pinouts Pin Signal Name Wire Color 1N o t u s e d 2 Line 2 Tip Black o r White/Orang e 3 Line 1 Ring Red or Blue/Whit e 4 Line 1 Tip Green or White/Blue 5 Line 2 Ring.
C-1 A PPENDIX C S PECIFICATIONS VDSL Func tional Crit eria Band Pl an: Up to 6 ba nds Signal Bandwidth: 25 kHz to 30MHz Optional Band: US0 operating at 4~25 kHz (low end) to 138~276 kHz (high end) Multi-Car rier-Modulation (MCM) - DM T modulation Interl eaving : general con vol ution T on e Spacing: 8.
S PECI FICAT IONS C-2 P ower Consumption 7 W att s maximum Input P ower 12 VDC (via A C power adap t er), 1 A maximum T y pical 700 mA maximum Size 15.
C OMPLIANCES C-3 Compliances CE Mark Emissions FCC Class B FCC P ar t 68 Indus tr y C anada C lass B EN55022 (CISPR 22) Class B EN 61000-3-2/3 CNS 13438 Class B Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/CUS (CSA 22.
S PECI FICAT IONS C-4.
Glossary-1 G LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet ov er two pairs o f Categor y 3, 4, or 5 UTP cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps F ast Ether net ov er two pa irs of Category 5 or be tter UTP ca ble . Auto-Negotiatio n Signall ing meth od allowing each node to select its optimum ope ratio nal mode (e.
G LOSSAR Y Glossary-2 Ethernet A network communication syst em developed and stand ardized by DEC , Intel, and Xe ro x, using baseband trans mission, CSMA/C D access, logical bus topolog y , and coaxial cable.
G LOSSAR Y Glossary-3 Local Area Network (LAN) A group of in terconnected computer and s uppor t devi ces . Media Access Control (MAC) A portio n of the ne twor king pr otocol th at g ov erns acces s to the transmission medium, facilitating the exchange of data between network nodes.
G LOSSAR Y Glossary-4 Transmission Control Protocol/Internet Protocol (TCP/IP ) Protoco l suit e that in clude s TCP as t he prima r y trans por t pr otocol, and I P as the netw ork la yer prot ocol. UTP Unshielded twiste d-pair cable. User Datagra m Protocol (UDP) UDP pro vides a dat ag ram mode for pack et-switc hed comm unicatio ns.
Index-1 Numerics 10BASE-T/100BASE-TX p in assignm ents B-2 C cable crossover B-4 straight- through B-3 testing category 5 cable B-4 cable connections 3-1 compliances emissions C-3 immunity C-3 safety .
I NDE X Index-2.
.
20 Mason Irvine, CA 92618 Phone: (9 49) 679-8000 Model Numbers: SMC7800A /VCP Pub. Number: 150200004100H E02 2007/ST -R01 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. an d Canada (2 4 hours a day , 7 da ys a week) (800) SMC-4-YOU; (94 9) 679-800 0; Fax: (949) 679-1481 Fro m Europe : Cont act de tails ca n be f ound o n www .
デバイスSMC Networks SMC7800A/VCPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SMC Networks SMC7800A/VCPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSMC Networks SMC7800A/VCPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SMC Networks SMC7800A/VCPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SMC Networks SMC7800A/VCPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SMC Networks SMC7800A/VCPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSMC Networks SMC7800A/VCPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SMC Networks SMC7800A/VCPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSMC Networks SMC7800A/VCPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。