Contents 24 1 INSTRUCTIONS FOR SAFE AND PROPER USE ____________________ 25 2 POSITIONING OF THE HOB ____________________________________ 27 3 ELECTRICAL CO NNECTION ___________________________________.
Introduction 25 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WH OLE WORKING LIFE OF THE COOKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB.
Introduction 26 THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB.
Instructions for the installer 27 2 POSITIONING OF THE HOB The following operation requir es building and /or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials s uch as masonry, metal, solid wood or plastic lamin at ed wood as long as they are heat resistant (T 90°C).
Instructions for the installer 28 A+B A+B A+B A+B B B Fig.1 2 0÷4 0 B A Fig.2 B A Fig.3 Fig.4 Fig.5.
Instructions for the installer 29 3 ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power lin e conform to the data shown on the plate located u nder the casing.
Instructions for the installer 30 4 GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. To facilitate connection, fitting A on the r ear of the appliance m ay be adjusted laterally.
Instructions for the installer 31 4.1 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisio ns of standards regu lations in force. Make s ure that feed pressure conforms to t he levels shown in t he table in paragraph “ 5.
Instructions for the installer 32 5 ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any clea ning or maintenance work, disconnect the appliance from the electrical socket. The hob has been inspected for G20 (2H) nat ural gas at a pressure of 20 mbar.
Instructions for the installer 33 5.3 Regulation for LPG Check that the connectio n has been made as d escribed in the “Gas connection” section. Undo the screw “ D ” and push the air regulator “ C ” fully d own.
Instructions for the installer 34 5.4 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform th e same operations described in para graph “ 5.
Instructions for the installer 35 5.5 Regulation of primary air Referred to distance “ A ” in mm. 60 cm hobs with separable control panel. Burner G20 20 mbar G30/G31 28/37 mbar Auxiliary (1) 3.0 4.0 Semirapid r (2) 1.0 2.0 Semirapid l (3) 1.0 2.0 Rapid large (4) 1.
Instructions for the installer 36 6 FINAL OPERATIONS Having carried out the above adj ustm ents, reassemble the applianc e following, backwards, the i nstructions in p aragraph “ 5.1 Removing the separable control pa nel / 5.2 Removing the hob”. 6.
Instructions for the installer 37 6.3 Arrangement of the b urners on the hob (Hob with separable control panel) 60 cm. hob BURNERS 1. Auxiliary 2. Semirapid r 3. Semirapid l 4. Rapid large 5. Ultrarapid 90 cm. hob BURNERS 1. Auxiliary 2. Semirapid 3. Rapid 4.
Instructions for the installer 38 6.4 Arrangement of the b urners on the hob (Hob with built-in control panel). 60 cm. hob BURNERS 1. Auxiliary 2. Semirapid r 3. Semirapid l 4. Rapid 5. Ultrarapid 6.5 Lubrication of gas taps With time it may happen that the gas taps get blocked and h ard to turn.
Instructions for the user 39 7 USING THE HOB Before turning on the burners, make sure that the burner rings, caps and grids have been fitted cor rectly. In the ultrarapid burner, notch A must be aligned with pin B . Grid C provided is intended for use with wok s (Chinese pans).
Instructions for the user 40 7.3 Diameter of the pans Burners Ø min. and max. (en cm.) Auxiliary 12-14 Semirapid 16-20 Rapid medio 22-26 Rapid large 22-26 Ultrarapid 22-26 Fish burner Special oval-shaped vessels 7.4 Electric elements 7.4.1 Turning on electric elements Hobs may be fitted with an electric elem ent of varying diameter.
Instructions for the user 41 WARNING When switching on the electric element for the first time, or if the electric element has not been used for a long time, to rem ove any humidity from the insulating material it should be drie d out by placing the el ectric element on position 1 for 30 minutes.
Instructions for the user 42 8 CLEANING AND MAINTENANCE Never use a steam jet to clean the appliance. Before any intervention, disconnect the power supply of the device. 8.1 Cleaning Clean the cooking top regularl y every time you use it, obviously after it has cooled.
Instructions for the user 43 8.2 Cleaning of cooking hob componen ts CAUTION: do not wash these components in a dishwasher. In normal use of the hob, the stai nless steel b urner caps and pan- stands tend to be burnishe d by the high temperature. Clea n these parts using very fine abrasive sponges or simil ar commercial products.
デバイスSmeg AP64S3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Smeg AP64S3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSmeg AP64S3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Smeg AP64S3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Smeg AP64S3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Smeg AP64S3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSmeg AP64S3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Smeg AP64S3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSmeg AP64S3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。