Contents 1. INSTRUCTIONS FOR SAFE AND PROPER USE ________________ 4 2. POSITIONING OF HOB ____________________________________ 6 3. GAS CONNECTION ______________________________________ 11 4. ELECTRICAL CONNECTION ______________________________ 12 5. ADAPTATION TO DIFFERENT TYPES OF GAS _______________ 13 6.
Introduction 1. INSTRUCTIONS FOR SAFE AND PR OPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN A N ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE C O OKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB.
Introduction THE IDENTIFICATION PLATE, W ITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER TH E CASING. THE PLATE ON THE CASING MUST NOT BE R EMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE CASING.
Instructions for the installer 6 2. POSITIONING OF HOB The following operation r equires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).
Instructions for the installer 7 Overall dimensions: location of gas and electrical connection points (all measures in mm). A 100 B 350 C 60 D 60.
Instructions for the installer 8 2.2 Clearance above and around domestic appliances Extract from AS5601 REQUIREMENTS 1 Overhead clearances – (Measureme nt A ) Range hoods and exha ust fans shall be installed in accor dance with the manufacturer’s instructions.
Instructions for the installer 9 2 Side clearances – (Measurements B & C) Where B , measured from the periphery of the n earest burner to any vertical com bustible surface , is less than 200 mm , the surface shall be protected in accorda nce with Clause 5.
Instructions for the installer 10 2.3 Room ventilation Caution – This hob may o nly be installed and operated in rooms permanently ventilated in accordance with current regulations. For proper operation of a gas a ppliance it is essential for the air nec essary for combustion of the gas to be able to flow naturally into t he room.
Instructions for the installer 11 3. GAS CONNECTION This appliance is su itable for installation with Natural Gas or ULPG (propane). R efer to page 12 for the relevant burner press ure and appropriate injector sizes. When the ap pliance is to be connected to Natural Gas then the pressure regulator supp lied must be fitted to the gas inlet.
Instructions for the installer 12 4. ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate locat ed under the casing.
Instructions for the installer 13 5. AD APT A TION T O DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, detach the appliance from the electrical socket. The hob has been adjusted for natural gas at a pressure of 1.0kPa. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted.
Instructions for the installer 14 5.2 Regulation for LPG Loosen screw A and push support B all the way. Use a d ouble head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use.
Instructions for the installer 15 5.3 Regulation for natural gas The hob has been adjusted for natura l gas at a pressure of 1.0kPa. To allow the unit to work back with this type of g as, after it has been adjusted for LPG, perform the same operations described i n paragraph “5.
Instructions for the installer 16 6. FINAL OPERA TIONS Having carried out the abov e adjustments, reassemble the applianc e following, backwards, the instructions in paragraph “ 5.1 Removing the hob ”. 6.1 Regulation of minimum for natural gas Replace the compon ents on the burner and slide the knobs on the gas tap pins.
Instructions for the user 17 7. USING THE HOB Before turning on the burners, make sure that the burner rings, caps and grids have been fitted correctly. In the ultrarapid burner, notch A must be aligned with pin B . Grid C provided is intende d for use with woks (Chinese pans).
Instructions for the user 18 7.2 Practical advice for usin g the burners For better burner performance an d minimum gas consumption, flat bottomed, even recipie nts must be used, with covers and proportiona l in size to the burners (see paragraph “ 7.
Instructions for the user 19 8. LEANING AND MAINTENANCE Before any intervention, disconnect the power supply of the device. 8.1 Cleaning Clean the cooking top regularly every time you use it, obviously after it has cooled.
Instructions for the user 20 8.2.1 Ignition plugs and safety devices For good functioning of the l ighting ignition plugs and the s afety devices, keep them very clean.
.
914773030/ B.
デバイスSmeg CIR597Xの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Smeg CIR597Xをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSmeg CIR597Xの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Smeg CIR597Xの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Smeg CIR597Xで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Smeg CIR597Xを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSmeg CIR597Xの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Smeg CIR597Xに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSmeg CIR597Xデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。