Contents 23 1 INSTRUCTIONS FOR SAFE A ND PROPER USE ____________________ 24 2 POSITIONING OF THE HOB ____________________________________ 26 3 ELECTRICAL CONNECT ION __________________________________.
Introduction 24 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB.
Introduction 25 THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB.
Instructions for the installer 26 2 POSITIONING OF THE HOB The following operation requ ires building and/or carpentr y work so must be carried out by a competent tradesman. Installation can be carried out on vari ous materials such as masonry, metal, solid wood or plastic laminat ed wood as long as they are heat resistant (T 90°C).
Instructions for the installer 27 Bracket ‘ A ’ in the 1st slot Bracket ‘ A ’ in the 2nd slot Bracket ‘ B ’ 2.2 Fixing 90 cm hobs on 60 cm base unit If a 90 cm hob is to be bracketed to a 6 0 cm base unit, 2 central brackets “ A ” have to be us ed in addition to the sid e brackets “ B ” as shown in the drawin g below.
Instructions for the installer 28 3 ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power lin e conform to the data shown on the plate located under the casing.
Instructions for the installer 29 4 GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the pr ovisions defined by standard regulations in force. To facilitate connection, fitting A on the r ear of the appliance m ay be adjusted laterally.
Instructions for the installer 30 4.1 Connection to LPG Use a pressure regulator and make the con nection to the tank according to the provisio ns of standards regulations in force. Make sure that feed pressure conforms to the leve ls shown in the tab le in paragraph “5.
Instructions for the installer 31 5 ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any c leaning or maintenance work, disconnect the appliance from the electrical socket. The hob has be en inspected for G25 (2L3B/P) natural gas at a pressure of 25 mbar.
Instructions for the installer 32 5.3 Regulation for LPG Check that the connection h as been made as descri bed in the “Gas connection” section. Undo the screw “ D ” and push the air regul ator “ C ” fully down.
Instructions for the installer 33 5.4 Regulation for G25/25 mbar The hob has been ins pected for G25 (2L3B/P) at a pressure of 2 5 mbar. To allow the unit to work wit h this type of gas, perform the same operations described in paragrap h “5.
Instructions for the installer 34 5.5 Regulation of primary air Referred to distance “ A ” in mm. 60 cm hobs with separable control panel. Burner G25 25 mbar G30/G31 28/37 mbar Auxiliary (1) 2.5 2.5 Semirapid r (2) 0.5 2.0 Semirapid l (3) 0.5 1.5 Rapid large (4) 0 2.
Instructions for the installer 35 6 FINAL OPERATIONS Having carried out the a bove adjustments, reassemble t he appliance following, backwards, the inst ructions in paragraph “5.
Instructions for the installer 36 6.3 Arrangement of the burners on the hob (Hob with separable control panel) 60 cm. hob BURNERS 1. Auxiliary 2. Semirapid r 3. Semirapid l 4. Rapid large 5. Ultrarapid 90 cm. hob BURNERS 1. Auxiliary 2. Semirapid 3. Rapid 4.
Instructions for the installer 37 6.4 Arrangement of the burners on the hob (Hob with built-in control panel). 60 cm. hob BURNERS 1. Auxiliary 2. Semirapid r 3. Semirapid l 4. Rapid 5. Ultrarapid 6.5 Lubrication of gas taps With time it may happen that the gas taps get blocked and h ard to turn.
Instructions for the user 38 7 USING THE HOB Before turning on the burners, make sure that the burn er rings, caps and grids have been fitted cor rectly. In the ultrarapid burner, notch A must be aligned wit h pin B . Grid C provided is intended for use with wok s (Chinese pans).
Instructions for the user 39 while cook ing, all pans o r griddles must b e positioned within the coo king hob perimeter and must be a minimum distance of 3-4 cm from the knobs.
Instructions for the user 40 or fish. 5 Strong For roasts, steaks and large boil ed joints. 6 Very strong To boil large amounts of w ater, to fry. WARNING When switching on the electric element for th.
Instructions for the user 41 8 CLEANING AND MAINTENANCE Never use a steam jet to clean the appliance. Before any intervention, disconnect the power supply of the device. 8.1 Cleaning Clean the cooking top regul arly every time you use it, obviously after it has cooled.
Instructions for the user 42 8.2 Cleaning of cooking hob components CAUTION: do not wash these components in a dishw asher. In normal use of the hob, the stai n less steel burner caps and pa n- stands tend to be burnishe d by the high temperatur e. Clean these parts using very fine abrasive sponges or simil ar commercial products.
デバイスSmeg SNL34AX1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Smeg SNL34AX1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSmeg SNL34AX1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Smeg SNL34AX1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Smeg SNL34AX1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Smeg SNL34AX1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSmeg SNL34AX1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Smeg SNL34AX1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSmeg SNL34AX1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。