Safety Precautions .......................................................................................... 1 Identification of parts ...................................................................................... 2 Indoor Unit / Operation and display .
Do not turn off the power supply cir- cuit breaker or pull out the unit power cord during unit operation. This may cause electrical hazards and/ or a fire. Keep the power supply circuit breaker and power plug free from any type of debris. If using a power supply cord, be sure to connect to plug firmly.
.
- 3 -.
.
.
.
.
.
- 9 -.
- 10 -.
.
.
.
- 14 -.
Specifications are subject to change without prior notice. Visit our website - www.soleusair.com Copyright 2003 Soleus International Inc. PERFORMANCE RATINGS MODEL Capacity Cooling [BTU/h] Capacity He.
- 16 -.
Outdoor unit installation location: l Outdoor unit location must be well ventilated. Avoid installing where any type of flammable gas could leak. l Proper clearances must be maintained per instructions on page 16. l The maximum length for refrigeration lines is 49 ft.
Installation instructions 3. Indoor unit refrigeration line installation l The refrigeration lines and wiring can be routed to the outdoor unit in a number of ways (left or right from the back of the unit), by using the cut-out access pieces on the casing of the unit.
- 19 -.
Suppport plate Hook Hook Mounting the Indoor unit to the Mounting Plate: l Hook the indoor unit onto the upper portion of the mounting plate by connecting the hooks at the rear top of the indoor unit with the upper edge of the mounting plate.
Installation instructions Outdoor unit installation 1. Install the outdoor unit l Outdoor unit must be mounted on a solid, level foundation. If possible, affix unit using bolts to the foundation.
Installation instructions 3. Wiring connection l Remove the electrical cover of outdoor unit (1 screw). l Connect wires as shown below in the illustrations.
Installation instructions System Start Up and Charge Adjustment Procedures The outdoor unit is supplied with a R-22 charge sufficient for 15 feet of refrigeration tubing. The outdoor unit’s liquid and suction valves are closed to contain the charge within the unit.
HOW TO INSTALL DRAIN ACCESSORIES There will be some water dripping from the condenser when the heat pump is working during the heating mode. Two drain caps, a drain elbow with rubber collar and a plastic hose (5/8” x 6”) are supplied for user’s choice.
- 25 -.
- 26 -.
.
USE COPPER WIRES ONLY FOR POWER SUPPLY. WARNING:RISK OF ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH. DISCONNECT ALL ELECTRIC POWER SUPPLIES BEFORE SERVICING. DURING CONNECTION OF THE REFRIGERATION TUBES, IF EXCESSIVE TORQUE IS IMPOSED ON FLARE NUTS, SERVICE VALVE ON DISCHARGE LINE MAY BE DAMAGED.
- 29 -.
Troubleshooting RUN light blinks Defect What to check 1 time 2 times 3 times 4 times Continuous blink Abnormality of room temperature sensor. Abnormality of defrost sensor. Abnormality of indoor fan motor. Abnormality of outdoor unit. No defect-unit in defrost mode.
デバイスSoleus Air KFR/KFS Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Soleus Air KFR/KFS Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSoleus Air KFR/KFS Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Soleus Air KFR/KFS Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Soleus Air KFR/KFS Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Soleus Air KFR/KFS Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSoleus Air KFR/KFS Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Soleus Air KFR/KFS Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSoleus Air KFR/KFS Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。