- Cooling - Heating - Dehumidifying - Fan Please read Owner’s Manual carefully before operating the unit . 1.
2 TABLE OF CONTENTS INTRODUCTION ........................................................................................................................................... 3 IMPORTANT SAFEGUARDS .......................................................
3 INTRODUCTION Thank you for purchasing the Soleus Air MA-9000AH portable air conditioner. This unit is designed to improve living and working comfort by providing cooling, dehum idifying and fan functions with only minimum installation required.
PACKAGE CONTAINS: 1 Portable Air Conditioner 1 Air Exhaust Duct 1 Window Kit (2 Sliding Panels) 1 Window Kit Adapter 1 Remote Controller 2 AAA Batteries 1 User Manual IDENTIFYING THE PARTS Front View .
Exhaust Duct Window Kit 5.
ASSEMBLY REQUIREMENTS 1) Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air m ust be directed out of the room. The exhaust duct is required to allow the hot air out of th e room through a window. DO NOT INSTALL OR USE THE EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN.
NOTE: In order to achieve maximum room cooling efficiency, the exhaust duct should remain as short and straight as possible. To further shorten the exhaust hose, first unthread either exhaust duct adapter clockwise to remove it. Then cut the hose to desired length.
Control Panel Functions 1. Power On/Off Control Starts or stops the unit 2. Temperature Setting Control Select the desired temperature setting by pressing either the or key. It is recommended to set the tem perature before selecting the Mode Control. 3.
a. When the unit is On, press “Timer” Button, then press the “Tim e” button until the desired number of hours is displayed in the lower right corner of the display window. The unit will automatically power Off once the selected number of hours has elapsed.
a. Be sure that the drain bucket is properly placed in the unit. If the drain bucket is not properly secured in the unit, the red “Water Full” light located on the front panel will blink and the unit will not begin dehumidifying. b. If exhaust duct is attached, remove it from the rear of the air conditioner c.
OPERATION USING REMOTE CONTROLLER REMOTE CONTROLLER 1. To Set the Clock Open the back cover of the remote controller and insert two AAA batteries. When batteries 11.
are installed or replaced, the clock is set to 12:00AM. To set present time: 2. Cooling Operation a. Be sure that the drain bucket is properly placed in the unit. If the drain bucket is not properly secured, the red “Water Full” light located on the front panel will blink and the unit will not begin cooling.
a. Plug the Power Cord to the power outlet. b. Turn on the unit by pressing the On/Off Button on the remote control. c. Press the Mode Button until “Heat” appears on the LCD display. d. Press the Temperature Button or until the desired room tem perature appears on the LCD.
desired number of hours is displayed in th e LCD. The unit will autom atically power Off once the selected number of hours has elapsed. b. When the unit is Off, press “Timer” Button, then press the “Hour” button until the desired number of hours is displayed in th e LCD.
is discharged by gravity through a drainage tube (12” length) to either an external hose (not included) or to a condensate water pump device (not included). When the unit is operating on continuous drainage mode, it can operate continuously without periodic stops to empty the water bucket.
1) Clean or Replace Filter a. If the air filter is clogged, the airflow volume will decrease, reducing cooling efficiency. It is recommended to clean the f ilter once a month or as needed. 16 b. Push down the tab on the filter cover and pull outwards to remove the entire filter and cover.
17 PROBLEM POSSIBLE CAUSE REMEDY Unit is unplugged Securely plug receptacle into the power outlet Drain bucket is full Empty water bucket Water bucket not installed correctly Completely insert water b.
18 MODEL MA-9000AH COOLING CAPACITY 9000 BTU/hr HEATING CAPACITY 1100 W DEHUMIDIFYING CAPACITY 88 Pints/Day COOLING/HEATING 1120W/1350W POWER DEHUMIDIFYING 1100W AIR FLOW VOLUME 180 CFM VOLTAGE 115 V 60 HZ 11.5 AMP COOLING POWER SOURCE RATED CURRENT 11.
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompa nying MA-9000AH Soleus Air air conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada.
デバイスSoleus Air MA-9000AHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Soleus Air MA-9000AHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSoleus Air MA-9000AHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Soleus Air MA-9000AHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Soleus Air MA-9000AHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Soleus Air MA-9000AHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSoleus Air MA-9000AHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Soleus Air MA-9000AHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSoleus Air MA-9000AHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。