B&Kメーカー1785Bの使用説明書/サービス説明書
ページ先へ移動 of 38
1 Instruction Manual Model 1785B, 1786B, 1787B & 1788 Programmable DC Power Supplies.
2 C ontent Quick Reference .............................................................................................................................. 3 About your safety .............................................................................
3 Quick Reference About your safety Pease review the following safety precautions before operating our equipment. General information The following safety precautions should be observed before using this product and any associated instrumentations.
4 Certification and Warranty Certification We certify that this product met its published specifications at time of shipment from the factory. Introduction The 1785B - 1788 Series power supplies are high performance single - output programmable DC power supplies with communication interface .
5 The Front Panel at a Glance 3 4 5 7 6 1 2 3 4 5 7 6 1 2 ? 10 digits VFD display ? Sta tus information for operating mode and working status ? Power s witch ? Number keys ? Function keys ? UP / DO WN.
6 Function k eys description Se t the output voltage value Se t the current value Sav e the present settings to a specified register location (1~16) Recall a s aved settings from location ‘‘1’.
7 Link The power supply is in communication mode Rmt The power supply is in remote mode Cal The power supply is in calibration mode The function keys are locked by password The rotate speed of cooling fan ON Output ON Oh Overheat protection state CV The power supply is in constant voltage mode.
8 C hapter 1 Quick Start One of the first things you will want to do with your power supp ly is to become acquainted with the front panel. The exercises in this chapter prepare the power supply for use and help you get familiar with some of its f ront - panel operations.
9 1.2 Output Checkout The following procedures check to e nsure that the power supply develops its rated outputs and properly responds to operation from the front panel. 1 .2.1 V oltage Output Checkout The following steps verify basic voltage functions with out load.
10 zero. 7 . Ensure that the current can be adjusted from zero to the full rated value. 8 . Turn off the power supply and remove the short wire from the output terminals. 1.3 If the Power Supply Does Not Turn On Use the following steps to help solve problems you might encounter when turning on the instrument.
11 Bench - top viewing positions Carrying position 1.5 To Rack Mount the Instrument You can mount the power supply in a standard 19 - inch rack cabinet using the IT - E151 rack mount kit . Note: Remove the carrying handle and the two plastic ears before rack - mounting the instrum ent.
12 To rack mount two ins truments side - by - side, order rack mount kit IT - E151 , you needn’t to use the front cover panel. Dimension unit (mm) Chapter 2 Specifications 2.1 Specifications Parameter 1785B 1786B 1787B 1788 Voltage 0 ~ 18V 0 ~ 32V 0 ~ 72V 0 ~ 32V Current 0 ~ 5A 0 ~ 3A 0 ~ 1.
13 Voltage < 0.05% + 10mV Programming Accuracy, 12months , ( @ 25 °C ± 5 °C) ± ( % of out put+offset) Current < 0.2 % +10mA Voltage < 0.05% + 15 mV (<20V) , < 0.05% + 12 0mV ( = 2 0V) Readback A ccuracy 12months , (25 °C ± 5 °C) ± ( % of output+offset) Current < 0.
14 Environmental Conditions Designed for indoor use in an installation c ategory II, pollution degree 2 envir onment. Designed to operate at maximum relative humidity of 95% and at altitudes of up to 2000 meters. Weight Type 1785B 1786B 1787B 1788 N.W 12.
15 Chapter 3 Front - p anel Operation So far you have learned how to install your power supply and do quick s tart. During the quick start, you were briefly introduced to operating from the front panel as you learned how to check basic voltage and current functions.
16 Step2. Press key . Step3. Use the num eric keys to or ? and ? keys to change the voltage value. Step4. Press to confirm the value 3.3 Constant Current Operation The constant current output range is from 0 A to the maximum current value of each type.
17 Step2. Select >MAX VO LT by using ? and ? key . Step3. Press key . Step4. Change the voltage value by using num eric keys to or ? and ? key . Step5. Press key . n Initiat ing the Output state (>INIT OUT) This instruction can ini tiate the output state when the power supply is powered on.
18 n Setting A d dress (>ADDRESS) This instruction can set the communicat ion address for each power supply . T he address range is from 0 to 254 . Before the communication, you must make sure that there is same address between the power supply and the compute r.
19 Chapter 4 Remo te Operation Mode The DB9 interface connector on the rear panel of the power suppl y can be transferred to RS - 232 interface , the following information will tell you how to use the computer to control the output of the power suppl y.
20 4.3 Frame format Frame length is 26 bytes, the format is as follows: Start Address Command 4 - 25 bytes are information content Check sum Description: 1 . Start bit is AAH, occup ies a byte. 2 . Address range is 0 to FE , occupies a byte. 3 . C ommand occupies a byte.
21 3 rd byte Command ( 20H ) 4 th byte Operation mode( 0 represent front panel operation mode, 1 represent remote operation mode) 5 th to 25 th byte System reserve 26 th byte Check sum 2 .
22 7 th byte The highest byte of output voltage value 8 th to 25 th byte System reserve 26 th byte Check sum 5 . Setting the output current ( 24H ) 1 st byte Start bit ( AAH ) 2 nd byte Address ( 0 ~ .
23 11 th byte To set the low byte of current value 12 th byte To set the high byte of current value 13 th byte B yte 0 of the maximum voltage value 14 th byte B yte 1 of the maximum voltage value 15 t.
24 1 st b yte Start bit( AAH ) 2 nd b yte Address( 0 ~ 0XFE) 3 rd b yte Command(28H) 4 th b yte Calibration protec tion state 5 th b yte System reserve 26 th byte Check sum 10 .
25 13 . S ending the actual out put current to calibration program ( 2CH ) 1 st byte Start bit (AAH) 2 nd byte Address( 0 ~ 0XFE) 3 rd byte Command( 2CH ) 4 th byte The lower byte of the present current value 5 th byte The higher byte of the present current value 6 th to 25 th byte System reserve 26 th byte Check sum 14 .
26 2 nd byte Address (0 ~ 0XFE) 3 rd byte Command ( 31H ) 4 th to 8 th byte Product model(ASIC code) 9 th byte Lower byte of the software version 10 th byte Higher byte of the software version 1 1 th to 20 th byte Serial number(AS C II code) 21 st to 25 th byte System reserve 26 th byte Check sum 18 .
27 26 th byte Check sum Chapter 5 Calibration We suggest you to ca librate the power supply yearl y . W e provide you a set of calibration software Power Calibration ( PC 1785B_1788 ). I t is very easy to calibrate the power supply by the calibration software.
28 5.1 Configur ation Start the PC 1785B_1788 System, the windows is as follows: The diagram of connecting the multi - meter to the calibrated power supply The diagram of connecting the multi - meter .
29 When you measure the output voltage or short current by the multi - mete r , please make sure the value is correct. Otherwise it will cause the calibration failure and let the output turbulence.
30 6.3 Functions of PV1785B_1788 Start the s oftware PV1785B_1788 , the windows is as follows: 1 4 2 3 5 8 6 7 9 10 11 C onfigure the software operati on environments . Voltage chart , it can show you a chart of the voltage . Current chart : it can show you a chart of the current.
31 6.3.1 Configure the system The first step for communicat io n is to configure the system, c lick Configure button , t he windows will display as follows: Note : W hen you set the communication port , please make sure that the baud rate and addre ss of the computer are the same as the power supply .
32 6.3.3 S et ting Voltage and current 1. Setting voltage/current by rotary knob Note: Before you set the current and voltage value from the compute r , please change the opera tion mode to PC Control mode by pressing button. 2. Quick ly setting Use mouse to click on the rotary knob and move mouse to change the value.
33 3. Program set ting 6.3.4. GO/NG Test Function Program: Right - click on the Program area, the program tools (Append a line, Insert a line, Delete a line, Delete Select etc.) will appear on the windo w . Click the tools to program the steps. Double - click on each value to change them from key board as you desired.
34 6.3.5 Save and Open To save the pr ogram settings , quickly settings, voltage sweep settings and GO/N G settings as PAR file. To open the PAR file for re loading the program settings, quickly settings, voltage sweep settings and GO/NG settings. 6.3.
35 To set the X - Axes Span To set the Y - Axes Span To set the limit position Click here and move to zoom in/out axes or scroll axes To set the ring buffer size Vertical marker Horizontal marker XY Value marker Limit range between the minimum value and maximum value.
36 Limited One - Year Warranty B&K Precision Corp. warrants to the original purchaser that its product and the component part s thereof, will be free from defects in workmanship and materials for a period of one year from the data of purchase. B&K Precision Corp.
37 Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the below address. Clearly state in writing the performan ce problem and return any leads, connectors and accessories that you are using with the device.
38 22820 Savi Ranch Parkway Yorba Linda, CA 92887 USA TEL: 714 - 921 - 9095 FAX: 714 - 921 - 64 22 ww w .bkprecision.com PN: 481 - 534 - 9 - 001 Printed in China 2005 B&K Precision Corp.
デバイスB&K 1785Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
B&K 1785Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはB&K 1785Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。B&K 1785Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。B&K 1785Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
B&K 1785Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はB&K 1785Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、B&K 1785Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちB&K 1785Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。