HTSD10X 10X Pan-T ilt S peed Dome Camera Please read this manual thoroughly before operation and kee p it handy for further reference..
2 W arning & Caution W h a t ’ s i n t h e B o x ? General Features N a m e s o f E a c h P a r t I n s t a l l a t i o n A . C o n n e c t i o n M e t h o d s B. Ceiling Mount T ype C. Embedded Mount T ype Quick Operating Keys Diagnostic OSD Menu Setting A .
3 WARNING & CAUTI ON If you fail to read this informa tion and handle the product incorre ctly , serious injury may occur . 1. Camera 2. Screws ( Ø4x16 screw 5EA ) 3. T erminal block (5pin 2EA) 4. Manual 5. Screw Cap (2 EA) Never install the product in area exposed to oil or gas.
4 GENERAL FEATURES 100X Zoom Mini Speed Dome 10X Optical Zoom with 10X digital zoom ± 0.02 ° dome sy stem accuracy With 0.1 ° technical accuracy , camera provides excellent sensitive and delicate c.
5 NAMES OF EACH PART 1. Surface Mount Adaptor 2. Cap Screw ( PT3/4 , 2EA ) 3. Dip Switch 4. T erminal Block 5. Main body.
6 A. CONNECTION METHOD A - 1 1. Loosen the scr ews on the domes cover a nd remove it from the base. (Screws will not come out) 2. Loosen the scre ws which connect the mount co ver and Main base and separate the dome cover from the main base. (Scre ws will not come out) 3.
7 B. MOUNT 1. Attach the surface mount adapto r with 4 screws at the installation site. (FIG .4) 2. When you use pipe, please note the sta ndard size of pipe.
8 1-64 + preset and 101~200 + preset are used for preset an d 65-100 + preset used fo r functions. For example, to enter OSD MENU, press the button 95 + PRESET .
9 When the Power is turned on a DIAGONOSTIC is operated. The following messages are displ ayed on the monitor . A. Pan Origin T est Zero point of Pan is founded af ter Panning test. B. T ilt Origin T est Zero point of T ilt is founded after T ilting test.
10 A. OSD MENU T ABLE OSD MENU SETTIN G MAIN MENU DOME SETUP CAMERA SET AUTO SCAN TOUR PRAVACY PATTERN ALARM SECTOR EXIT DOME SET CAMERA ID : CAM1 □□□□□□□□□□□□ RECOVER : OFF MA.
11 T o enter the OSD Menu, pr ess the button 95 + PRESET . * Use the joystick “up - down” to mo ve the position and “left - right” to make selection B. Dome Setup T o enter the Dome setup, move t he joystick right to move the cursor . B-1. DOME SET - CAMERA ID T o set camera ID, select up to 16 characters using Joystick l eft or right.
12 B-2. DOME SET - RECOVER This feature allows the dome to work from t he last setting before you us e the dome manually (Auto scan, group tour , pa ttern or sectors) , after the set time, even po wer shut down and it turns on again. Recovery time can be pro grammed from 15 second to 90 seconds.
13 B-8-2. DOME SET – [NEXT P AGE] – [P ASSWORD] T o enter this page to set a password, move the joys tick to the right directi on. The password must be set by preset number from 001 to 255 (Default 99) A. OSD MAIN MENU T ABLE (P A GE 1 1) The default setting is BLANK.
14 B-8-4. DOME SET – [NEXT P AGE] – [SYSTEM ST A TUS] This page shows the information of this camera. - Protocol and baud rate are sho wn according to the dip switch setting (Refer to page 29, 30 and 31) - Firmware version and upgra ded date will be changed if upgra ded.
15 - T o clear memorized dat a, move joystick to the right direction when cursor is on each item. Press FOCUS NEAR b utton when the cursor is at YES in order to clear memorize d data. Then each item such as tour , preset, sector and so on is displa yed on the monitor about 2~ 3 seconds.
16 C. CAMERA SET C-1. CAMERA SET - FLICKERLES S Flickerless feature is selected bet ween 50Hz and 60 Hz. T he default setting is OFF (NTSC: 60Hz / P AL: 50Hz). Set flicker mode ON when power source is in discord with frequenc y . The default setting is OFF C-2.
17 C-6. CAMERA SET – PIC FLIP Picture flip feature turns ths picture upside do wn. Mo ve the joystick to the right or left direction to select OFF/ON. The default setting is OFF . C-7. CAMERA SET – BLC (Back Light Compe nsa tion) The default setting is OFF and BLC modes can be OFF /ON.
18 D. PRESET SET T o enter PRESET SET , move the joystick to the right direction. D-1. PRESET – PRESET NO. Up to 164 numbers of preset positions are availa ble. Move joystick to the right or left direction t o select a preset no. D-2. PRESET – PRESET ID T o set preset ID, select up to 16 char acte rs using Joystick to the lef t or right.
19 E. AUTO SCAN SET * 66 + preset b utton is working as AUTO SC AN after setting. E-1. AUTO SCAN – ST ART ANGLE T o set the start angle, press FOCUS F AR button then move the joys tick to the starting angle which is to be memorized. Press FOCUS FAR button again is to escape.
20 F . TOUR SET 8 Programmable tours can be set and each tour is av ail able to set up to 64 preset steps. After setting the data to each tour group, 71~78 + preset buttons are working as gr oup tour # 1~8 F-1. TOUR SET – T OUR NO. Max. 8 grou p tour no.
21 G . PRIV ACY SET 4 Privacy masking zones are avail able to block out areas of the scene. G-1. PRIV ACY SET – PRIV ACY NUMBER. Up to 4 privacy masking zones are availab le. G-2. PRIV ACY SET – DISPLA Y . Move joystick to the right or left direction to se t ON in order to show the selectable block in the center of the monitor .
22 H. P A TTERN SET 8 programmable patterns are available with 16 characters of title. After setting the data to each pa ttern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8. H-1. P A TTERN SET –P A TT NO. Up to 8 programmable user-define d patterns set by the joystick are available.
23 I. ALARM SET 4 Alarm input s are available and each alarm can activate presets, group tours or patterns. I-1. ALARM SET – ALARM NO. Up to 4 alarms are selectable by using the joystick to the right when the cu rsor is on ALARM NO.
24 J. SECTOR SET Up to 8 programmable sectors are available with 1 6 characters. This feature is useful to memorize ce rtai n locations such a s a parking zone, etc. When a camera goes through this area, it sho ws the letter you memorized. J-1. SECTOR SET – SECT OR NO.
25 A-1. DIP SW SETTING This S peed Dome camera provides up to 63 camera ID’s, adjustable using the 1 st ~6 th Dip switch. Open the camera case to set ID using DIP SW1.
26 A-3. PROT OCOL 7 th ~8 th dip switches are used for Protocol Setting. Factory Default: Pelco-D or Pelco-P ( Auto detection) DIP SW1- 7 DIP SW1- 8 OFF OFF Pelco-D or Pelco -P A-4. BAUD RA TE SETTING T h e 9 th Dip Switch is used for BAUD RA TE setting.
27 If you have trouble operating in your camera, refer to the following. PROBLEM SOLUTION Not operating Check if the power supply is 12 VDC. Check if RS-485 communication cable is connected correctly . Check camera ID setting. Check the termination. No pic ture Check if all the cables are con nected correctly .
28 MODEL HTSD10X PAN /TILT Pan Rotation Angle 360 ˚ Endless Pan Speed Manual 10 ˚ ~ 200 ˚ /sec Preset Max 200 ˚ /sec Tilt Rotation Angle 0 ˚ ~ 90 ˚ Tilt Speed Manual 10 ˚ ~ 200 ˚ /sec Preset Max 200 ˚ /sec System Accuracy 0.
29 DIMENSIONS.
30 MEMO.
31.
32 S peco T echnologie s is constantly developing p roduct improvement s. We reserve the right to modify product d e sign and specifications without notice and without incurring any obligatio n.
デバイスSpeco Technologies HITSD10Xの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Speco Technologies HITSD10Xをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSpeco Technologies HITSD10Xの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Speco Technologies HITSD10Xの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Speco Technologies HITSD10Xで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Speco Technologies HITSD10Xを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSpeco Technologies HITSD10Xの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Speco Technologies HITSD10Xに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSpeco Technologies HITSD10Xデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。