/ Mar le y Class 60 0 Cooling T ower /.
2.
3 / Flexibility of Design / Class 600 cooling towers are a dir ect descendent of the Doubleflow ® crossflow tower that was designed and patented by Marley in 1938.
4 Fans Marley designed and manufactured fans ar e used on all Marley crossflow towers. The fan selection and fan speed for a given tower are based on tower cell size, system losses, and horsepower requir ements. Depending on fan size, blade material is FRP (fiber reinfor ced polyester), GRE (glass reinfor ced epoxy), or cast aluminum alloy .
5 Geareducer The Marley Geareducer ® has become the standar d by which all other cooling tower fan speed reducers are judged. Numer ous reduction ratios ar e available so that horsepower is applied at optimum fan speed. The specific Geareducer selection is based on fan speed and horsepower requir ements up to 300 hp per fan.
6 Class 600 splash fill bars are available in the following materials: • PVCin“Omega”,“Mega”or“Alpha” configurations. • Injection-moldedpolypropylene“Ladder” configurations. • Roughsawn,preservative-tr eatedwood “G” configurations.
7 Piping Although side inlet piping is provided as standar d, Class 600 towers are adaptable to end inlet piping. This is an economical method requiring only one riser for each series of hot water basins, regar dless of the number of fan cells. Cast iron, steel, and r einforced plastic pipe ar e all available.
8 / Dr ift Eliminat ors / Marley towers utilize Marley XCEL ® plus drift eliminators, a cellular , labyrinthine design which improves drift elimination by several orders of magnitude over that achievable by blade-type eliminators. Significantly lower pressur e losses also reduce fan horsepower requir ements.
9 The diagonals brace the structure and carry loads to heavy-duty , hot dip glavanized anchor castings. The anchor castings transmit wind and/or earthquake loads from the structur e directly into the foundation. For standard wind load conditions, anchor bolts ar e requir ed only at the perimeter .
10 / Casing / The endwalls of Class 600 towers are cased fr om the fan deck level to below the top of the basin curb with 8 oz/sq ft corrugated FRP sheets. FRP is waterproof and corrosion pr oof, is immune to biological deterioration, and requir es no maintenance.
11 Endwall Derrick The endwall derrick is a permanently installed tripod device of galvanized structural steel. In service, removable structural aluminum tracks are positioned acr oss the platform opening. Equipment to be handled is placed on a 4-wheel dolly—part of the equipment handling package—rolled onto the track and elevated slightly .
SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project.
デバイスSPX Cooling Technologies 600の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SPX Cooling Technologies 600をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSPX Cooling Technologies 600の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SPX Cooling Technologies 600の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SPX Cooling Technologies 600で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SPX Cooling Technologies 600を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSPX Cooling Technologies 600の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SPX Cooling Technologies 600に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSPX Cooling Technologies 600デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。