C ooling liquid r efill Installation manual For XLM, DP90 and DP100 R59770032/00 24/08/2006.
Barco nv Eve nts Noordl aan 5, B-8520 Kuurne Phone: +32 56.36.89.70 Fax: +32 56.36.88.24 E-mail: sales.events@barco.com Visit us at the web: www.barco.
1. About the coo ling circuit and coo ling liquid 1. ABOUT THE COOLING CIRCUIT AND COOLING LIQUID 1.1 Overview of the Coolin g circuit Cooling c ircuit flow and p arts During operation, a closed loop of flexible tubing circulates cooling liquid to critical components, such as the engine and to the integrator rod entry .
1. About the cooling circu it and cooling liquid BLUE ANTIFREEZE DILUTED 1,2 ETHANEDIOL (1/3 ETHANEDIOL-2/3 DEMI WATER) NOT FOR HOUSEHOLD USE KEEP OUT OF REACH OF CHILDREN.
1. About the coo ling circuit and coo ling liquid - Immerse the inlet tube end without fitting as far as possible into the bottle with fresh cool ing liquid (1). - Open the fitting by pressing-in valve mechanism (2) to allow filling the immersed tubing with liquid.
1. About the cooling circu it and cooling liquid 4 R59770032 COOLING LIQU ID REFILL 24/08/2006.
2. Replacement of the co oling liquid 2. REPLACEMENT OF THE COOLING LIQUID 2.1 Insertion/Removing valved fitting How to handle Image 2-1 Insertion/Removing hose connectors Insertion T o avoid damage to the connector seal, always dep ress connector tab (1) prior to in serting (2).
2. Replacement of the cooli ng liquid The liquid cooling loop - Replacement of liquid Engine Pump Vane Outlet Inlet Expansion Vat Manometer Heat Exchanger Light Pipe entry Pressure relief valve (3 Bar.
2. Replacement of the co oling liquid 2. Push the valved fitting of the filled tube into the Inlet ’I N’ of the cooling circuit. Ensure the loose end of the tube remains immersed in the liquid.
2. Replacement of the cooli ng liquid Bottle filled with fresh cooling liquid Outlet Inlet Image 2-5 Unwanted bubbles expe lling (in practice) 3. Switch On the projector .
2. Replacement of the co oling liquid 8. Pressure cooling loop to 1 Bar , using appropriate air pump and ad apter . OK Image 2-7 Pressurizing expan sion vat R59770032 COOLING LIQU ID REFILL 24/08/2006.
2. Replacement of the cooli ng liquid 10 R59770032 COOLING LIQU ID REFILL 24/08/2006.
3. Liquid Co oling Refilling, e xpelling air 3. LIQUID COOLING REFILLING, EXPELLING AIR 3.1 Refilling, expelling air When? Minor drops in pressure over time are to be expected. Once the m inimu m pressure of 0.5 bar is reached, proceed with refilling procedure.
デバイスBarco DP90の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Barco DP90をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBarco DP90の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Barco DP90の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Barco DP90で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Barco DP90を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBarco DP90の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Barco DP90に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBarco DP90デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。