SterlingメーカーSDA 1000-5100の使用説明書/サービス説明書
ページ先へ移動 of 61
SDA 1000-5100 Large Dehumidifying Dryers with AP0 Controls Part Number: 882.00292.00 Bulletin Number: DH1-605 Effective: 12/01/05 Write Down Your Serial Numbers Here For Future Reference: ____________.
Large Dehumidifying Dryers ii Shipping Info Unpacking and Inspection You should inspect the large dehumidifying dryer for possible shipping damage. Thoroughly check the equipment for any dam age th at might have occurred in transit, such as broken or loose wiring and components, l oose hardware and mounting screws, etc.
Large Dehumidifying Dryers iii Returns Do not return any damaged or incorrect items until you receive shipping instructions from the shipping departme nt. Credit Returns Prior to the return of any material authorization m ust be given by the manufacturer.
Large Dehumidifying Dryers iv Table of Contents CHAPTER 1: SAFETY ................................................................ 8 1-1 How to Use This Manual ...........................................................................................
Large Dehumidifying Dryers v Setting the Process Air Temperature .................................................................. 29 Restoring the Process Air Temperature Controller (E5CN) to Factory Settings.. 29 Process Air Dew Point Display .....
Large Dehumidifying Dryers vi 8-5 Dryer Identification (Serial Number) Tag ................................................................... 58 8-6 Technical Assistance.................................................................................
Large Dehumidifying Dryers Safety 7 Chapter 1: Safety 1-1 How to Use This Manual Use this manual as a guide and reference for in stalling, operating, and maintaining the large dehumidifying dryer. The purpose is to assist you in applying effici ent, proven techniques that enhance equipment productivity.
Large Dehumidifying Dryers Safety 8 Dryer Safety Tags Tag Description Tag Description Read Operation & Installation Manual High Voltage Inside Enclosure Hot! Lifting Point PE Protected Earth Groun.
Large Dehumidifying Dryers Safety 9 ; Only PROPERLY TRAINED personnel familiar with the information in this manual should work on this equipment. We have long recognized the importance of saf ety and have designed and m anufactured our equipment with operator safety as a prime consid eration.
Large Dehumidifying Dryers Safety 10 employer probably has established a set of safet y rules in your workplace. Those rules, this manual, or any other safety information will not keep you from being injured while operating your equipment. Learn and always use safe operation.
Large Dehumidifying Dryers Safety 11 When you need to perform maintenance or repa ir work on a dehumidifying dr yer above floor level, use a solid platform or a hydraulic elevat or. If there is a permanently installed catwalk on your dryer, use it. The work platfor m should have secure footing and a place for tools and parts.
Large Dehumidifying Dry ers Functional Description 12 Chapter 2: Functional Description 2-1 Models Covered in This Manual This manual provides operation, installation, an d maintenance instructions for 6 00-3000 cfm Large Dehumidifying Dry ers with AP0 contro l.
Large Dehumidifying Dry ers Functional Description 13 moisture is stripped from the air by a desiccant bed. The dried process air is then re-heated and delivered back into the drying hopper to dr y material again. This system is a "closed loop", because ambien t (outside) air is never introduced into the process air.
Large Dehumidifying Dry ers Functional Description 14 Regeneration Filter Regeneration Blower Process Blower Regeneration Exhaust Process Heater Process Filter Insulated Drying Hopper Right Desiccant .
Large Dehumidifying Dry ers Functional Description 15 2-3 Controller Description The AP0 control package uses a relay logic cont roller to control the operation of the dryer. See below for descriptions of each screen. Figure 2: Controller Screen Descriptions Regen Set Screen.
Large Dehumidifying Dry ers Functional Description 16 2-4 Standard Features Mechanical Features ; 180ºF – 250ºF Drying temperature range ; High regeneration temperature control safeties ; 13X desi.
Large Dehumidifying Dry ers Functional Description 17 2-5 Options Closed-Loop Regeneration An optional regeneration closed-loop valve and heat exchanger can be used to close the regeneration loop during the cooling portion of the regeneration cycle.
Large Dehumidifying Dry ers Functional Description 18 Process Air Dust Collector The optional process air dust collector consists of a filter, dust can, pressure gauge, and optional pressure switch (see Figure 5). The gauge will let you know whether it is time to clean out your filters.
Large Dehumidifying Dry ers Functional Description 19 Figure 6: Material Miser/Air Balance Valve Coupling Temperature Probe Drying Hopper Valve Proofing Switch Mechanical Options ; Low temperature ope.
Large Dehumidifying Dry ers Functional Description 20 2-6 Safety Devices and Interlocks This section includes information on safety devices and procedures that are inherent to the large dehumidifying dryer. This manual is not in tended to supersede or alter safety standards established by the user of this equipment.
Large Dehumidifying Dry ers Functional Description 21 In addition to the safety devices listed above, th ese dehumidifying dryers are equipped with a line cord plug. This allows the operator or maintenance personnel to unplug the system from its power source and tag it out.
Large Dehumidifying Dry ers Mechanical Installation 22 Chapter 3: Mechanical Inst allation 3-1 Uncrating the Equipment The large dehumidifying dryers are shipped mounted on a skid, encl osed in a plastic wrapper, and contained in a cardboard box. 1. Pry the crating away from the skid.
Large Dehumidifying Dry ers Mechanical Installation 23 ; The power drop must include a ground wire. ; Make sure all electrical connections are tight. 3-4 Checking for Proper Blower Rotation After the electrical connections have been made, check the process and regeneration blowers for proper blower rotation.
Large Dehumidifying Dry ers Mechanical Installation 24 3-5 Making Dryer/Drying Hopper Process Air C onnections When making process air connections to your drye r, ensure that you take into consideration and make arrangements for the following: ; Use high-temperature flexible dryer hose or rigid tubing to co nnect the dryer to the drying hopper.
Large Dehumidifying Dry ers Mechanical Installation 25 After cooler Model Water Flow ( GPM ) AD600 10 AD850 10 AD1000 15 AD1250 15 AD1500 20 AD2000 25 AD2500 30 AD3000 35 High Temperature Gasket Stain.
Large Dehumidifying Dry ers Mechanical Installation 26 3-7 Using the Drying Hopper Air Trap Our exclusive air trap assembly in the top of the drying hopper prevents am bient air from contaminating the material being dried .
Large Dehumidifying Dryers Controls 27 Chapter 4: Controls 4-1 Controller Description and Operation Identifying Control Panel Indicator Lights and Switches for the Standard Controller Switches System OFF/ON/START Switch. This switch energizes or de-energizes control power to the indicator panel and starts the dryer.
Large Dehumidifying Dryers Controls 28 Identifying Process Air Temperatu re Controller LED Indicators Indicator Name Description PV 8.8.8.8 Process Value Numeric LED During normal operation, the process value ( PV ) numeric LED indicator displays the process temperature at the To Process thermocouple.
Large Dehumidifying Dryers Controls 29 Identifying Temperature Controller Keys Indicator Name Description Mode Key Press the Mode key to shift the display to the next set of parameters. The menu screen displays. Down Key Press the Down arrow key to lower the process air set point temperature.
Large Dehumidifying Dryers Controls 30 Available E5CN Modes Operation Level Indicator Name Description Run/Stop Mode (r-S) When “RUN” is selected, the control is running. When “STOP” is selected, the control is stopped. When the control is stopped, the STOP display lights.
Large Dehumidifying Dryers Controls 31 Entering Operating Parameters to Select Modes To enter the display: 1. Press the Mode Display key to view the Run/Stop & Alarm 1 Modes. 2. Press and to set the higher or lower the values of the parameter or turn that function On or Off.
Large Dehumidifying Dryers Controls 32 Process Air Dew Point Display Optional The Process Air Dew Point meter indicates the cu rrent process air delivery moisture content. Standard dryers use a microprocessor-based controller for displaying dew point air temperature.
Large Dehumidifying Dryers Controls 33 Redundant Safety Controller Display Optional The Redundant Safety Controller limits the pr ocess air temperature from exceeding the upper temperature range set by the E5CN Temperature Controller. Standard dryers use a microprocessor-based controller for limiting the process air temperature.
Large Dehumidifying Dryers Controls 34 Entering Operating Parameters to Select Modes To enter the display: 1. Press both the Up and Down keys for three seconds from the home page. The word SEE will appear in the upper display and PAGE will appear in the lower display.
Large Dehumidifying Dryers Operation 35 Chapter 5: Operation 5-1 Initial Start-up Pre-Startup Checks ; Check the process and return hoses for tight connections. ; Check all companion equipment, such as the drying hopper; verif y that the loading system is ready for operation.
Large Dehumidifying Dryers Operation 36 5-2 Dryer Operation Procedures Controller Operation (Without Optional Alarm Horn & Reset Button) 1. Turn the disconnect on the control panel to the ON position. Power is applied to the voltage line fuses, line side of the control power switch and the temperature controller.
Large Dehumidifying Dryers Operation 37 5. If the Regen E5CN controller faults, a re gen high heat fault is generated. “RH” is displayed on the relay screen. The alarm light is activated. The process heater, regen heater, and process/regen blower are turned off.
Large Dehumidifying Dryers Operation 38 on the relay screen. Press ALARM RESET to deactivate the alarm until the next dew point fault occurs. 15. Use the right arrow key to display the REGEN SET screen (Screen 1). Use the up & down arrow keys to select the parameter to change.
Large Dehumidifying Dryers Operation 39 18. Turn selector switch to START position to start the dryer. The bed switch valve will cycle to a known good position. The process & regen blowers will start. Process & Regen heaters are enabled. A new regen heat/cool cycle is started.
Large Dehumidifying Dryers Operation 40 PF - PROCESS FILTER RF - REGEN FILTER CV - CLOSED LOOP VALVE BV - BED SWITCH VALVE PS - PROCESS TEMP SWITCH RS - REGEN TEMP SWITCH PH - PROCESS HI TEMP Screen 6. PL - PROCESS LOW TEMP RH - REGEN HI TEMP DP - DEWPOINT PR - REDUNDANT SAFETY 5-4 Auto-Tuning the Dryer 1.
Large Dehumidifying Dryers Maintenance 41 Chapter 6: Maintenance 6-1 Maintenance Schedule The checklist below contains a list of items that should be inspected and/or replaced to keep your Large Dehumidifying Dryer operating at peak efficiency. Perform each inspection at the regular intervals listed below.
Large Dehumidifying Dryers Maintenance 42 6-2 Preventative Maintenance Cleaning or Replacing the Process Air Filters Regular filter cleaning will keep your dryer op erating at peak efficiency. The process air filters protect the centrifugal blowers from pl astic fines being drawn in from the dr ying hopper.
Large Dehumidifying Dryers Maintenance 43 Use the following procedure to clean or replace the filter cartridges: 1. Turn off and/or lock out el ectrical power to the dryer. 2. Remove the hand knobs or clamps securi ng the filter a ccess cover and remove the cover.
Large Dehumidifying Dryers Maintenance 44 5. Remove the restricted filter cartridge from the housing again. The alarm light should stay off when the process blower operate s if the switch is adjusted correctly. 6. Re-install the obstructed cartridge filter.
Large Dehumidifying Dryers Maintenance 45 6-3 Corrective Maintenance Symptoms of Worn Out Desiccant The moisture adsorption capacity of the desi ccant used in Large Dehumidifying Dryers degrades after an indefinite period of time.
Large Dehumidifying Dryers Maintenance 46 6. Inspect the gaskets on each of the covers. Replace if necessary. 7. Re-install the covers. Figure 17: Desiccant Tower Assembly Regeneration Heater Cover. High Temperature Gaskets. Heater Element Mounting Plate.
Large Dehumidifying Dryers Maintenance 47 High Temperature Gasket Double Wall Stainless Steel Heater Housing Heater Elements Heater Element Mounting Plate Stainless Steel Heater Housing Cover High Temperature Gasket Heater Assembly Gude Bars 1. Remove the bolts securing the process heater access cover.
Large Dehumidifying Dryers Maintenance 48 1. Access the desiccant canisters by removing the panels on the dryer. 2. Remove the Regeneration Heater Cover. 3. Unscrew the six (6) screws on the Heater Element Mounting Plate. 4. Slide out the heater assembly, taki ng care to not damage the gaskets.
Large Dehumidifying Dryers Troubleshooting 49 Chapter 7: T roubleshooting 7-1 Introduction The utmost in safety precautions should be observed at all times when working on or around the machine and the electrical components.
Large Dehumidifying Dryers Troubleshooting 50 Problem Possible Cause Corrective Action Process heaters are faulty. Replace. Desiccant beds are contam i nated. Replace desiccant . Material being dried differs from material specified at the time of purchase.
Large Dehumidifying Dryers Troubleshooting 51 7-3 Alarms The Alarm Screen will pop up to show what alarm the dryer is having that moment. Look through the window on the door to see the screen. 7-4 Alarm Descriptions Alarm Code Alarm Description Alarm Effect BV The Main Air Valve did not maintain or find position.
Large Dehumidifying Dryers Troubleshooting 52 7-5 Determining Temperature Contro ller Errors or Sensor Errors Using a Thermocouple If the controller displays a temperature that is close to room temper.
Large Dehumidifying Dryers Appendix 53 Chapter 8: Appendix 8-1 Warranty The manufacturer warrants all equipment manufactured by it to be free from defects in workmanship and material when used un der recommended conditions.
Large Dehumidifying Dryers Appendix 54 8-2 Technical Specifications Annex B Information The following design information is provided for your reference: 1. No modifications are allowed to this equi pment that could alter the CE compliance 2. Ambient temperature: 0 degrees Celsius – Maximum (104 degrees Fahrenheit) 3.
Large Dehumidifying Dryers Appendix 55 8-3 Drawings and Diagrams Regen. Filter Regeneration Blower Process Blower Optional After-cooler Process Air Filter Insulated Drying Hopper Left Desiccants Right Desiccants Process Heater Optional Regeneration Closed Loop Cooler Optional Regeneration Closed Loop Valve Regen.
Large Dehumidifying Dryers Appendix 56 PS Differential Pressure Switch Filter Check Gage E F Dust Level Indicator Slide Gate Clamp Dust Pan Filter Retainer Dust Shroud Cartridge Filter Thumb Screws Op.
Large Dehumidifying Dryers Appendix 57 8-4 Spare Parts List 600CFM 600CFM 600CFM 600CFM 600CFM 850CFM 850CFM 850CFM 850CFM 850CFM 1000CFM 1000CFM 1000CFM 1000CFM 1000CFM 1250CFM 1250CFM 1250CFM 1250CF.
Large Dehumidifying Dryers Appendix 58 8-5 LEVEL 3 ( Electrical Components ) 600CFM 600CFM 600CFM 600CFM 600CFM 850CFM 850CFM 850CFM 850CFM 850CFM 1000CFM 1000CFM 1000CFM 1000CFM 1000CFM 1250CFM 1250C.
Large Dehumidifying Dryers Appendix 59 8-5 Dryer Identification (Serial Number) Tag (Located on back of Dryer) XXX Series Dryer Model Number XXX-15 Max Drying Capacity HR 460V Serial Number 060701R 1 Date of Manufacture 06/2003 4.5A Over-current Protec tion Device (s) 4.
Please note that our address and phone i nformation has changed. Please reference this page for updated contact information. These manuals are obsolete and are provided only for their technical information, data and capacities.
Large Dehumidifying Dryers Appendix 60 8-6 Technical Assistance Parts Department Call toll-free 7am–5pm CST [ 800 ] 423- 3183 or call [ 630 ] 595- 1060, Fax [630] 475-7005 The ACS Customer Service G.
デバイスSterling SDA 1000-5100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sterling SDA 1000-5100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSterling SDA 1000-5100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sterling SDA 1000-5100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sterling SDA 1000-5100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sterling SDA 1000-5100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSterling SDA 1000-5100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sterling SDA 1000-5100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSterling SDA 1000-5100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。