Riva Open Log Burning Convector Fireboxes 16", 22", 24", 26" & 28" Standard and Low models PM219 - Issue 1 (June 2008) Instructions for Use, Installation and Servicing For use in Great Britain and Republic of Ireland.
2 COVERING THE FOLLOWING MODELS: 8610/8611/8604/8605/8606/8607/8608/8609/8673 COMMISSIONING 27 MAINTENANCE & SERVICING 28 Annual Service 28 Removal of Flue Damper 28 SERVICE RECORDS 30 EC DECLARAT.
3 APPLIANCE COMMISSIONING CHECKLIST Dealer appliance was purchased from Name: .............................................................................................................................................................................
4 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance. 1.3 Only use for domestic heating in accordance with these operating instructions.
5 WARNING Properly installed operated and maintained this appliance will not emit fumes into the room. Occasional fumes from de-ashing and refuelling may occur.
6 4. LIGHTING THE APPLIANCE 4.1 For best results: •Setdamper contro ls,SeeDia gram 6 PR8068 Open Close •Place firelighters or paperand dry kindling.
7 The multi-fuel kit is fitted as shown: Note that this kit must only be used with the appropriate Steel frame, Diagram 10. PR8070 •Set Primary Air Control , see Diagram 11 PR8071 - Closed.
8 — Smoke and small flames — Short life span for grate 6.3 Flue Draught The chimney has two main functions: 1) To safely remove the smoke, gases and fumes from the house. 2) To provide a sufficient amount of draught (suction) in the appliance ensuring the fire keeps burning.
PR8074 Poker 7.3 Remove components carefully. Heat can remain long after use, See Diagram 16 PR8076 PR8075 Multi-fuel Kit Cast Basket Ashpan Ashpan Grate Damper/ Multi-fuel tool Where a steel frame is.
10 13. CHIMNEY SWEEPING 13.1 To maintain safe and efficient use of the appliance the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep.* If the appliance is used continuously throughout the year or it is used to burn wood or smokeless fuel, more frequent sweeping is recommended.
RIVA OPEN TECHNICAL SPECIFICATION 1. STANDARD FEATURES • DamperControl • Primaryair (under grate air for fullmulti-fuel use)* * Multi-fuel kits 8705, 8710, 8720 only 2.
TECHNICAL SPECIFICATION 16" Low 22" Low 24" Low 26" Low 28" A 474 474 624 624 674 674 724 724 774 B 592 542 652 592 652 592 652 592 652 C 348 348 348 348 348 348 348 348 348 D.
13 16" 22" 24" 26" 28" Profil Brass - standard height 8633 8635 8637 8639 8626 Profil Brass - low lintel 8674 8636 8638 8640 - Profil Brushed Stainless - standard height 8633B.
14 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks.
SITE REQUIREMENTS 15 3.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in diagram. If it is to be fitted in a raised setting consideration may need to be given to extending the depth of the hearth to safely containing any falling logs or embers.
SITE REQUIREMENTS 16 4. BUILDERS OPENING To make installation easier make the opening larger than the minimum requirements where possible. B A FRONT C Appliance Dim A Dim B Dim C 16" 420 560 360 .
PRE-INSTALLATION CHECKS Model Flue/Chimney Size Without liner system (round) minimum dimension (diameter.) mm 200 200 200 200 200 inch 8 8 8 8 8 Without liner system (square) minimum dimension mm 185 185 185 185 185 inch 7 1/4 7 1/4 7 1/4 7 1/4 7 1/4 Liner or factory made system (diameter.
2.2 Extractor fans or cooker hoods should not be placed in the same room or space as the appliance. 2.3 If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified. 2.1 Open appliances require additional ventilation to comply with the requirements of the Building Regulations.
LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations* and standards**, along with any local regulations and working practices that may apply.
3 PR8079 2A. FITTING OF FUEL KITS - LOG 2.1 Install the relevant fuel box . 4 PR8080 2.2 Fit the Log Retainer ( Holyrood , Castle , Portcullis ), Diagram 5. Note: the Holyrood retainer has a specially curved log- burning tray. 5 PR8081 Back of Log Retainer Retaining clips • Fit retaining clips over the front lip of Log Box 2.
21 INSTALLATION INSTRUCTIONS 2.6 Or • Fit a Multi-fuel box , Diagram 9 This must be done with the frame removed, see Section 3 9 PR8084 2.7 Fit a Contemporary Multi-fuel Log bar , Diagram 10 Slide into channels in the front of the Multi-fuel Box and cutout in grates.
22 INSTALLATION INSTRUCTIONS 14 PR8087 3.3 Steel Square/Rectangular Frames •Drill 4 Ø 7.5 holes in required positions, 16" Diagram 12, 22" Diagram 15, 26" Diagram 16 A 1:1 scale drilling template is provided with the frame to assist in correctly locating the holes.
20 PR8090 Air deflector not shown for clarity 3A. REMOVABLE BOTTOM FRAME PLATE 3A.1 The steel frames have a removable bottom plate to allow easy access to the space below for Ash Removal with a vacuum cleaner nozzle.
INSTALLATION INSTRUCTIONS 24 4. FITTING AN OPTIONAL FLUE GATHER 4.1 Fitting Of Optional Flue Gather 16" 22" 24" 26" 28" Flue gather - standard (central) - 8658 8659 8660 8661 .
25 INSTALLATION INSTRUCTIONS •Position the back andside cast firebricks onthe grate behind the raised ribs, See Diagram 30 30 •Slide the ashpan (G)u.
26 INSTALLATION INSTRUCTIONS 8. FITTING AND REMOVAL OF TRADITIONAL SPARKGUARD 16" 22" 24" 26" 28" Traditional clip-in spark guard -std 8690 8691 8692 8693 8694 Traditional cli.
COMMISSIONING 27 COMMISSIONING 1.1 To commission: • Check the soundness of seals, castings and joints (Convector box flange and flue gather) •C heck the operation of the air controls 1.
28 1. ANNUAL SERVICE 1.1 Before the start of the heating season strip, inspect and clean the appliance as detailed: •Allow appliance to cool •Remove all of thefo.
29 NOTES.
30 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
31.
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.
デバイスStovax PM219の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Stovax PM219をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはStovax PM219の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Stovax PM219の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Stovax PM219で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Stovax PM219を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はStovax PM219の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Stovax PM219に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちStovax PM219デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。