Air Conditio ver the years, Subaru air conditioning systems have taken many differ ent shapes and sizes, from full manual, cable and vacuum-contr olled systems like those found on Loyale models, to the fully automatic electronically contr olled systems employed by the SVX and some Legacy models.
oning Systems Air Flow System The purpose of the air flow system is to provide air to the heating, ventilation, defroster , and air conditioning systems.
Fast Idle Control Device (A/C Idle Air Control) On manual transaxle equipped Justy vehicles, the FICD is incorporated in the idle-up system. Proper adjustment and operation is outlined in Service Bulletins 02-70-89 and 02-72-89. On ECVT equipped carbureted vehicles an air/fuel bypass contr ol system performs the FICD function.
T roubleshooting and Servicing Six Step T roubleshooting The following six step method of troubleshooting will save time and ef fort in the diagnosis and analysis of air conditioning problems. It pr ovides a logical approach to solving the problem, not just tr eating the symptoms.
End Wrench The T o connect the manifold gauge set to the system: ➊ Fully close both of the manifold valves. ➋ Remove the compressor service valve caps. ➌ Connect the high and low pressur e hoses to the service valves. Note: Some refrigerant gas will be dischar ged as the hoses are connected to the service valves.
General Preparations Always conduct a visual inspection of the air conditioning system to identify any damage, excessive wear , refrigerant leaks (oil residue), impr oper belt adjust- ment, improper pulley alignment, and plugged condenser cooling fins.
Air Condit ioning Charging Charging the system is r equired after servicing, r epair or replacement of system components, or to locate a leak when there is no r efrigerant in the system.
Oil Refill Subaru Air Conditioning Systems Systems End Wrench The 12 Fill the compressor with the pr oper amount of the correct type r efrigerant oil. Use of the incorrect type of compr essor oil may result in damage to the com- pressor .
End Wrench The Subaru Air Conditioning Systems Standard Compressor Systems ➊ System performs to specifications; test complete ➋ Higher than normal pressur es indicate: —Restriction of air across.
デバイスSubaru R-12の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Subaru R-12をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSubaru R-12の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Subaru R-12の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Subaru R-12で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Subaru R-12を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSubaru R-12の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Subaru R-12に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSubaru R-12デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。